Hans Premium Water Premium Water Reverse Osmosis Modules Instruction Manual

Premium Water Reverse Osmosis Modules

HANSTM Premium Water RO System Model 2

The HANSTM Premium Water RO System Model 2 is an appliance
designed to provide clean and safe drinking water. It features a
four-stage system that removes sediment, debris, chlorine,
chloramines, sulfur, lead, arsenic, PFAS, iron, hardness, and other
contaminants. The system reintroduces minerals for pH balance and
better taste. The appliance has a rugged exterior with a heavy-duty
molded housing that provides quiet operation indoors and
long-lasting protection outdoors. It also has cooling vents that
keep the unit running cool. The intuitive touch-screen and
quick-release pin system make filter and membrane changes easy.

Technical Specifications

  • Water temperature (min/max): 6 to 11
  • Ambient temperature (min/max): 65°F to 200°F
  • Feed pressure (min/max): 30 psi to 65 psi
  • pH level (min/max): <3,000 ppm
  • Output pressure: 110-240V, 50/60Hz; dedicated GFCI
  • Maximum Inputs:
    • PFOA/PFOS: 25,000 ppt
    • Lead: 150 ppb
    • Iron: 2 ppm
    • Arsenic: 50 ppb
    • Nitrate: 30 ppm
    • Nitrite: 3.5 ppm
    • Hardness: 20gpg
    • Chromium 6: 300 ppb
    • Chromium Total: 300 ppb
    • Barium: 10 ppm
    • Radium: 25 pCi/L
    • Fluoride: 8 ppm
    • Chlorine: 4 ppm
    • Chloramines: 4 ppm
    • Turbidity: 1 ntu

Input levels outside of device parameters may require
pretreatment such as a water softener or iron breaker. The system
is designed and assembled in an ISO 13485 facility in Michigan.

Product Usage Instructions

The HANSTM Premium Water RO System Model 2 is easy to install
and use. Here are the instructions:

  1. Locate a suitable location for the appliance that is near the
    water source and has access to electricity.
  2. Connect the three connection points in the following order:
    1. Inlet water
    2. Clean water out
    3. Reject water out
  3. Plug the appliance into a dedicated GFCI outlet.
  4. The variable-speed pump will automatically adjust its speed
    depending on water demand, which uses less power and is more
    efficient than single-speed pumps.
  5. The appliance has an intuitive touch-screen that provides easy
    servicing.
  6. The quick-release pin system makes filter and membrane changes
    a snap.
  7. If you have high-demand applications, you can install multiple
    HANSTM Premium Water RO System Model 2 appliances in parallel. This
    can drastically reduce downtime as one unit can be taken off-line
    for service without disrupting water flow, keeping your business
    running and profitable.

-,
HANSTM Premium Water RO System Model 2
Residential· Commercial· Industrial Agriculture· Healthcare·
Hospitality· Food & Beverages

1350 mm

Model 2: Everything for clean water in one brilliant appliance

Easy installation
Three connection points 1. Inlet water
2. Clean water out 3. Reject water out
Variable-speed pump
Automatically adjusts speed depending on water demand. Uses less power and is more
efficient than single-speed pumps.
740 mm

Stage 4 calcite

Stage 1 filter

Stage 2 filter

Integral surge tank

Stage 3 membranes

990 mm

Easy servicing
Removable lid and side panels.
Rugged exterior
Heavy-duty molded housing provides quiet operation indoors and long-lasting protection outdoors.
Cooling vents
Fans keep the unit running cool.

Intuitive touch-screen
· Constantly monitors water quality and usage.
· Provides data on filter life, incoming and outgoing TDS levels, and water pressure.
· Wireless communication via mobile app.
· Wi-Fi enabled firmware updates.
Easy servicing
Quick-release pin system makes filter and membrane changes a snap.

HANSTM Premium Water RO System Model 2 is the first water treatment solution of its kind. · Reduces contaminant levels by up to 99.9% · Reduces TDS (up to 3,000 ppm) levels by up to 99% · Industry-best recovery rate of up to 90%
· Output of up to 34 litres per minute · Removes hardness… without salt** · Adds minerals for taste and pH balance · Provides clean water for your whole business or home · Continuously monitors water quality and usage · Variable-speed pump that adjusts for fluctuations in water
demand · Automatically detects incoming TDS levels and adjusts to
compensate for fluctuations · Designed for well water and municipal water using chlorine or
chloramines · Does not require an add-on pressure tank
Four-stage system
1. Removes sediment and debris. 2. Removes chlorine, chloramines and sulfur. 3. Removes lead, arsenic, PFAS, iron**, hardness** and a
host of other contaminants. 4. Reintroduces minerals for pH balance and better taste.

Ideal installation verticals

· Residential

· Food & beverage

· Commercial

· Healthcare & laboratories

· Industrial

· Facilities & services

· Agriculture

For high-demand applications, multiple HANSTM Premium Water RO System can be installed in parallel. This can drastically reduce downtime as one unit can be taken off line for service without
disrupting water flow, keeping your business running and profitable.

HANSPremiumWaterAsia.com

HANS'”

Model 2 Technical Specifications

Operating Limits
Water temperature (min/max) Ambient temperature (min/max) Feed pressure (min/max) p H level (min/max) Output pressure Operating pressure Output TDS input Power

2°C to 35°C 2°C to 48°C 30PSI to 60PSI
6to 11 65 PSI 200 PSI “34litres/min < 3,000ppm 110- 240V , 50/ 60Hz; dedicated GFCI

Maximum Inputs
PFOA/PFOS Lead Iron Arsenic Nitrate Nitrite Hardness Chromium 6 Chromium Total Barium Radium Fluoride Chlorine Chloramines
voes
Turbidity

25,000 ppt 150 ppb 2ppm 50ppb 30ppm 3.5 ppm 20gpg 300 ppb 300 ppb 10ppm 25 pCi/L 8ppm 4ppm 4ppm
(detailed list available) 1 ntu

Specifications subject to change without notice .

..Input levels outside of device parameters may require pretreatment such as a water softener or iron breaker.

Designed and assembled in an ISO 13485 facility in Michigan.

©2020 HANS Power & Water, LLC

2020911

ML080 Rev A

6 Serangoon North Ave 5 #06-01 Singapore 554910 Email: [email protected]

Third-party test results
Hardness** Iron (ferric and ferrous)** Fluoride Nitrate Nitrite PFOA&PFOS Lead Arsenic (A 3and A 5) Chromium 6 Chloroform Surrogates ( 48chemicals)

Tested at (Before) 700ppm ( 41gpg) 3.46 ppm 7.54 ppm 27.9 ppm 3.3 ppm 25,000 ppt 139 ppb 52.4 ppb 304 ppb 282ppb

HANS Result (After) <1.0 ppm .Q18ppm 0.8 ppm 0.9 ppm 0.2 ppm <5ppt <1.0 ppb <1.0 ppb <1.0 ppb <0.2 ppb

99.99% reduction of bacteria and 99.9% of reduction in viruses Detailed test results available at HANSPremiumWater .com ppm = parts per million · ppb = parts per billion ppt = parts per trillion · gpg = grains per gallon *Model 1results .Model 2results are pending .

Follow us on:

HANSPremiumWaterAsia.com