550GPH-77379 Oase Aquarius Fountain Set Eco 550 Pump
Product Information: This product is a water
feature with a pump. It is intended for installation and use in
outdoor settings. The unit should be installed at least 2 meters
away from water to ensure protection against flooding. The unit is
not suitable for use in swimming ponds due to the risk of
electrical voltage in the water. It is important to connect the
unit to a properly grounded receptacle to reduce the risk of
electric shock. Chemical cleaning agents should not be used to
clean the unit, as they can be harmful to animals, plants, and the
environment. Product Usage Instructions: 1.
Installation and Connection: – Install the water feature at least 2
meters away from water to protect against flooding. – Do not
install the unit directly adjacent to the water to avoid the risk
of severe injuries or death by electrocution. – Follow the provided
instructions for installing the pump. – Ensure that the unit is not
operated in a swimming pond. – Connect the unit to a properly
grounded receptacle. 2. Adjusting the Water Feature: – Refer to the
provided instructions (ARS0045) for adjusting the water feature. 3.
Commissioning/Start-up: – Make sure that the unit is connected only
to a properly grounded, grounding-type receptacle. – Do not connect
the pump to a dimmer, as it may cause damage to the pump. 4.
Maintenance and Cleaning: – Use clear water and a soft brush to
clean the unit. – Avoid using chemical cleaning agents, as they can
be harmful. – Clean the unit at least twice a year or as required.
– Pay particular attention to cleaning the impeller unit and pump
housing. 5. Opening/Closing the Housing: – Before closing the
housing, place the power cable in the recess to prevent it from
being crushed. – Follow the instructions provided for opening and
closing the housing (ARS0041 and ARS0042). 6. Cleaning/Replacing
the Impeller Unit: – Follow the provided instructions (ARS0046) for
cleaning or replacing the impeller unit. 7. Storage/Winter
Protection: – Refer to the user manual for instructions on storing
and protecting the unit during winter. 8. Malfunction Remedy: – If
the pump does not run, check the mains voltage and clean the
impeller unit. – If there is an insufficient delivery rate, clean
the impeller unit and check for any clogs in the filter housing or
excessive pressure loss in the hose. – If the unit switches off
after a short running period, check the water temperature and
ensure that the unit is not overloaded.
Intended use
Only use the product described in this manual as follows: · For pumping normal pond water for filter systems, waterfall systems and water
course systems. · For household use only. · Operate in accordance with instructions. (Technical data) The following restrictions apply to the unit: · Do not use in swimming ponds. · Never use the unit with fluids other than water. · Never run the unit without water. · Do not use for commercial or industrial purposes. · Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive
substances.
Installation and connection
Installing the water feature
In addition to the water feature, you can connect a rivulet or waterspout to the stepped hose adapter (hose diameter ½, ¾ or 1 in).
ARS0038
6
Englis h
Installing the pump
WARNING
Severe injuries or death due to operation of this unit in a swimming pond. Defective electrical components will electrify the water with dangerous electrical voltage. Never operate the unit in a swimming pond.
WARNING
The unit is subject to dangerous voltage and must not be installed directly adjacent to the water. Otherwise there is a risk of severe injuries or death by electrocution. Install the unit at a distance of at least 2 m from the water to ensure that it is pro-
tected against flooding.
· Ensure that the connection to the power supply is at least 6.6 ft from the pond. · Place the pump horizontally on a stable, mud-free surface. · The pump is under water, the nozzle intake emerges from the water.
TIP! Thoroughly clean the pond or pool and place the pump approx. 200 mm above the bottom of the pond, so that no muddy water runs through the pump. · Muddy water will cause the nozzle to clog faster and the impeller unit to become
worn prematurely.
Adjusting the water feature
ARS0045
ARS0040
7
Commissioning/start-up
WARNING
Risk of electric shock. This unit is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that the unit is connected only to a
properly grounded, groundingtype receptacle.
NOTE
Never connect the pump to a dimmer. Otherwise the pump will be destroyed.
· Switching on: Plug the power plug into the outlet. The unit switches on immediately.
· Switching off: Pull the power plug from the outlet.
Maintenance and cleaning
NOTE
Never use chemical cleaning agents. These are hazardous to animals, plants and the environment. Only use clear water and a soft brush to clean the unit.
Recommendation regarding cleaning: Clean the unit as required, but at least twice a year. When cleaning the pump, pay particular attention to the impeller unit and the
pump housing.
Opening/closing the housing
Before closing the housing, place the power cable in the recess in the housing to prevent it from being crushed.
Opening the housing
Closing the housing
ARS0041
ARS0042
8
Englis h
Cleaning/replacing the impeller unit
· Remove the pump cover or pump housing from the motor housing by turning it counter-clockwise (bayonet catch).
· After removing the impeller unit, clean all parts under running tap water. · Replace a worn or damaged impeller unit. · Assemble in the reverse order.
ARS0046
Storage/winter protection
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected. How to correctly store the unit: · Thoroughly clean the unit, check it for damage and replace any damaged parts. · Store the pump submerged and in a frost-free environment.
Malfunction remedy
Malfunction Pump does not run
Insufficient delivery rate
Possible cause No mains voltage Impeller unit blocked Impeller unit running sluggishly Filter housing clogged Pressure loss in the hose too high
Unit switches off after a short Water temperature too high running period
Unit is overloaded
Remedy Check the mains voltage. Clean the impeller unit Clean the impeller unit
Clean the filter housing. · Reduce the hose length and
connecting pieces to a minimum · Route hose in a straight line Adhere to the maximum water temperature of +77 °F (+35 °C) · Remove blockage · The unit will switch on again automatically as soon as it has cooled down.