Sealey Ven200.v4 Portable Ventilator Instruction Manual

VEN200.V4 Portable Ventilator

Product Information

The Portable Ventilators with Ducting are available in three
models: VEN200.V4, VEN250.V2, and VEN300.V3. These ventilators are
manufactured to a high standard and are designed to provide years
of trouble-free performance when used according to the provided
instructions and properly maintained.

It is important to read and understand the safety requirements,
warnings, and cautions outlined in the instruction manual. Failure
to use the product correctly and with care for its intended purpose
may result in damage, personal injury, and will invalidate the
warranty. Please keep these instructions safe for future
reference.

Product Usage Instructions

Electrical Safety

  • Before using the ventilator, check all electrical equipment and
    appliances to ensure they are safe. Inspect power supply leads,
    plugs, and electrical connections for wear and damage.
  • Sealey recommends using a Residual Current Device (RCD) with
    all electrical products.
  • If the ventilator is used for business purposes, it must be
    maintained in a safe condition and routinely tested using Portable
    Appliance Test (PAT).
  • Ensure that the insulation on all cables and the appliance is
    safe before connecting it to the power supply.
  • Regularly inspect power supply cables and plugs for wear or
    damage. Check all connections to ensure they are secure.
  • Make sure the voltage rating on the appliance matches the power
    supply. The plug should be fitted with the correct fuse as
    indicated in the instructions.
  • Do not pull or carry the appliance by the power cable.
  • Do not pull the plug from the socket by the cable.
  • Do not use worn or damaged cables, plugs, or connectors. Any
    faulty item should be repaired or replaced immediately by a
    qualified electrician.
  • If the cable or plug is damaged during use, switch off the
    electricity supply and discontinue use. Repairs should be done by a
    qualified electrician.
  • Replace a damaged plug with a BS1363 3 pin plug. If unsure,
    consult a qualified electrician.
  • Follow the correct wiring instructions: connect the
    GREEN/YELLOW earth wire to the earth terminal ‘E’, the BROWN live
    wire to the live terminal ‘L’, and the BLUE neutral wire to the
    neutral terminal ‘N’. Ensure that the cable outer sheath extends
    inside the cable restraint and that the restraint is tight. Sealey
    recommends having repairs done by a qualified electrician.
  • The replacement fuse rating for the ventilator is 3A.

General Safety

  • Disconnect the ventilator from the mains power when not in use
    and before servicing or performing any maintenance.
  • Use the ventilator only in dry areas. Do not use it in wet or
    highly condensation-prone locations such as bathrooms, showers, or
    pools.
  • If the ventilator falls into water, immediately switch off the
    mains power supply and disconnect it. Do not touch the ventilator
    until the mains power supply has been disconnected.

PORTABLE VENTILATORS WITH DUCTING
MODEL Nos: VEN200.V4, VEN250.V2, VEN300.V3
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Refer to instruction
manual
1. SAFETY

1.1.
1.1.1. 1.1.2. 1.1.3.
8 8 8
1.1.4.
1.2 9 9 8 9 9 9 8 8 8 8 8 8 8 9

ELECTRICAL SAFETY

WARNING! It is the user’s responsibility to check the following:

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all

electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical

products.

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance

Test) tested.

Electrical safety information: it is important that the following information is read and understood.

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct

fuse – see fuse rating in these instructions.

DO NOT pull or carry the appliance by the power cable.

DO NOT pull the plug from the socket by the cable.

DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or

replaced immediately by a qualified electrician.

This product is fitted with a BS1363 3 pin plug.

If the cable or plug is damaged during use, switch the electricity supply and remove from use.

Ensure that repairs are carried out by a qualified electrician.

Replace a damaged plug with a BS1363 3 pin plug. If in doubt contact a qualified electrician.

A) Connect the GREEN/YELLOW earth wire to the earth terminal `E’.

B) Connect the BROWN live wire to the live terminal `L’.

C) Connect the BLUE neutral wire to the neutral terminal `N’. Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. Sealey recommend that repairs are carried out by a qualified electrician.

Replacement fuse rating: 3A

GENERAL SAFETY

Disconnect the ventilator from the mains power when not in use, and before servicing or performing any maintenance.

Use the fan in dry areas only. Do not use in wet or high condensation locations such as bathrooms, showers, or pools.

WARNING! If a ventilator falls into water, immediately switch off at the mains and disconnect from the mains power supply.

DO NOT touch the ventilator until the mains power supply has been disconnected.

Always disconnect the ventilator from the power supply when moving it from one location to another.

Keep the ventilator clean and maintain in good condition (use an authorised service agent).

Use recommended parts only (unauthorised parts may be dangerous, and will invalidate your warranty).

DO NOT stand the ventilator where it may be knocked over or off a surface, or where the lead may cause a trip hazard.

DO NOT use an extension cord unless it has been approved by an electrical authority.

DO NOT insert any objects through the fan guard.

DO NOT allow children to operate the ventilator.

DO NOT immerse the ventilator in water or any other liquid.

DO NOT use the ventilator outdoors.

DO NOT cover the ventilator.

When not in use store in a safe, dry, childproof location.

2. INTRODUCTION

Ideal for use where high-volume clean air delivery is required. Especially designed to easily ventilate hot or fume laden work areas, creating a cleaner and more pleasant working environment. Supplied with 5m ducting (VEN200AK1). Optional 10m ducting (VEN200AK2) available, but not supplied. The air mover/ventilator can be used across multiple industries including, but not exclusive to; marine, roof spaces and building sites, cable/pipe ducts and workshops. Light weight in construction with large carry handle makes it easily portable. Fitted with 2m cable and 3-pin plug. Ducting supplied is compatible with other leading manufacturers products with Ø200mm.

© Jack Sealey Limited

Original Language Version VEN200.V4, VEN250.V2, VEN300.V3 Issue: 3 30/01/23

3. SPECIFICATION

Model No:. . . . . . . . . . . . . . . . . .VEN200.V4 . . . . . . . . . . . . . . . . . . VEN250.V2 . . . . . . . . . . . . . . . . . . . . . . . VEN300.V3 Air Flow:……………………. 1500m³/hr(882cfm) – 25m³/min……. 2700m³/hr(1589cfm) – 45m³/min…………..3900m³/hr(2295cfm) – 65m³/min Efficiency category: . . . . . . . . . . .static . . . . . . . . . . . . . . . . . . . . . . . static…………………………………………………………. static Efficiency grade: . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . . . . . . 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Fan Diameter: . . . . . . . . . . . . . . .200mm . . . . . . . . . . . . . . . . . . . . . 250mm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300mm Fan Speed: . . . . . . . . . . . . . . . . .2800rpm . . . . . . . . . . . . . . . . . . . . 2800rpm . . . . . . . . . . . . . . . . . . . . . . . . . . . 2800rpm Fuse rating: . . . . . . . . . . . . . . . . .None stated . . . . . . . . . . . . . . . . . 13A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10A IP Rating: . . . . . . . . . . . . . . . . . .IP55 . . . . . . . . . . . . . . . . . . . . . . . IP55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP55 Max.Airflow:………………..1500m³/hr(882cfm) – 25m³/min……. 2700m³/hr(1589cfm) – 45m³/min…………..3900m³/hr(2295cfm) – 65m³/min Measurement category:. . . . . . . .C. . . . . . . . . . . . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Noise Level: . . . . . . . . . . . . . . . .61dB(A) . . . . . . . . . . . . . . . . . . . . 66dB(A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61dB(A) Overall efficiency (n):. . . . . . . . . .45.8% . . . . . . . . . . . . . . . . . . . . . . 42.8% . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51% Power:. . . . . . . . . . . . . . . . . . . . .180W . . . . . . . . . . . . . . . . . . . . . . 300W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500W Replacement Ducting (5mtr):. . . .VEN200AK1 . . . . . . . . . . . . . . . . . VEN250AK1 . . . . . . . . . . . . . . . . . . . . . VEN300AK1 Replacement Ducting (10mtr):. . .VEN200AK2 . . . . . . . . . . . . . . . . . VEN250AK2 . . . . . . . . . . . . . . . . . . . . . VEN300AK2 Static Pressure:. . . . . . . . . . . . . .3.1mbar . . . . . . . . . . . . . . . . . . . . 3mbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9mbar Supply: . . . . . . . . . . . . . . . . . . . .230V ~ 50Hz. . . . . . . . . . . . . . . . . 230V ~ 50Hz . . . . . . . . . . . . . . . . . . . . . 230V ~ 50Hz

4. 230V ~ 50HZ OPERATION

4.1.

Decide on the direction of air flow, depending on your requirement (ventilate or extract). See fig 1 for direction of air flow.

4.2.

Ducting can be attached to either end of the ventilator depending on whether you wish to remove/extract fumes or deliver

fresh air into a work space.

4.3.

To change direction of air flow rotate the unit 180° as the air flow is a fixed direction.

4.4.

Secure ducting by pulling the string tight then move the toggle switch to start the unit; select a low or high fan speed as required.

NOTE: The ducting has locating lugs attached to it; these can be used to suspend the ducting if required.

DIAGRAM SHOWS VENTILATION OPERATION

Extraction side Air Flow
fig.1

Ventilation side

ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

REGISTER YOUR PURCHASE HERE

WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information.

Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team on [email protected] or 01284 757505. Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

01284 757500

[email protected]

www.sealey.co.uk

© Jack Sealey Limited

Original Language Version VEN200.V4, VEN250.V2, VEN300.V3 Issue: 3 30/01/23

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals