Circa Wall Top
Product Information:
The product is a wall top assembly for tapware, specifically
designed for installation in finished walls. It includes various
components such as a handle body, set screw, dress ring, locking
sleeve, fibre ceramic disc, washer spindle, and tap seat body. The
tap seat body should be positioned between 2 to 12mm below the
finished wall surface. The product is compatible with standard wall
breeches and can be used with new or existing installations.
The product code for the wall top assembly is RWTA for the
standard version and RWTA-V for the Vertex version. It meets the
AS/NZS 3718:2005 standard and is licensed under LIC. 20081. The
recommended working water pressure is 300-500 kpa, and the maximum
water temperature is 65 deg.c.
Product Usage Instructions:
Rough in plumbing:
- Upon receiving the tapware, carefully unpack it, and separate
the parts as shown in the diagram. - Install the spindles hand-tight until the seal makes contact
with the seat. - To ensure a good seal, tighten the spindles slightly more using
an appropriate spanner. Do not over-tighten to avoid damaging the
ceramic discs. - Place the fibre washer over the seated spindle and fit the
locking sleeve tightly. - Seal the wall around the locking sleeve and immediately fit the
dress ring. - Fit the handle body onto the spindle, ensuring it is fully
engaged. Apply a mild adhesive to the set screw when securing it to
the spindle. - Tighten the set screw using the provided 2mm Allen key.
- After completing the installation, establish water supply,
check the function of the tapware, and ensure there are no water
leaks.
Rough in (new wall breech):
- Use a standard wall breech (not supplied) in conjunction with
the tapware. - Prepare a nogging to be fitted 30-35mm back from the front of
the stud for fixing the wall breech. - Ensure the tap seats of the breech will be level and square to
the finished wall. - Calculate the thickness of the finished wall coverings before
rough in. If using thicker than normal wall covering, position the
breech as forward as possible to ensure proper fit of the
tapware.
Using existing breech (changing tapware only):
- Remove the old spindles and clean the surrounding area.
- When installing new spindles into old breaching, it is
recommended to use a re-seating tool to dress the seat. - Ensure the spindle seat is clean, flat, and free of any
debris. - Flush all lines completely before fitting the spindles.
- The distance from the finished wall surface to the top of the
tap seat must be between 2 to 12mm. If not within these dimensions,
alternative spindles are available for purchase. - Do not use seat or breech body extensions with this tapware as
it will void the warranty.
For more information, visit sussextaps.com.au
Circa
Wall top assembly
Side View
Combined finished Wall Surface Tile & Plaster 20mm
Handle Body
Set Screw
54mm
Dress Ring
Locking Sleeve
75 mm
40mm
Fibre
Ceramic Disc
Washer Spindle
Set Screw contact point
The Tap Seat Body must be between 2 to 12 mm below the Finished Wall surface
Front of Stud
30mm to
35mm from front
of Stud Nogging
STANDARD TAP SEAT
BODY
Rough in plumbing
– Upon receiving, carefully unpack the Tapware; note some parts have been combined for packaging purposes. – Separate parts as shown in diagram. The Spindles are supplied with Hot and Cold indication. – Install the Spindles hand-tight until the seal of the Spindle makes contact with the seat. – To ensure a good seal is made; tighten the Spindle slightly more using an appropriate spanner. Do not over-
tighten. – Note, over-tightening the Spindles could damage the ceramic discs and in turn, void the manufacturer’s
warranty. – Place the Fibre washer over the seated Spindle and fit the Locking Sleeve. (Tighten well). – Seal the wall around the Locking Sleeve and immediately fit the Dress Ring. – Fit the Handle Body, the Handle Body must be fully engaged onto the Spindle; note the Set Screw contact point.
(See diagram) – A mild adhesive can be applied to the Set screw when securing to the spindle. – Secure the Handle body by tightening the Set screw using the 2mm Allen key provided. (Tighten well) – After completing the installation, establish water supply, check function of Tapware and ensure no water leaks.
Product code
RWTA RWTA-V
Wall top assembly Wall top assembly – Vertex
Rough in (new wall breech)
– A standard Wall Breech (not supplied) is to be used in conjunction with this Tapware. – Prepare a nogging to be fitted 30 – 35mm back from the front of the stud for the fixing of the Wall Breech
(as shown). – When fixing the Breech to the nogging; ensure the Tap seats of the Breech will be level and square to the
Finished Wall. – To ensure the Tapware will fit correctly the thickness of the finished wall coverings must be calculated prior to
“Rough In”. – When using thicker than normal wall covering, position the breech as forward as possible to ensure the Tapware
will fit.
Using existing breech (changing tapware only)
– Remove the old Spindles and clean surrounding area. – When installing new Spindles into old Breaching, it is highly recommended to use a re-seating tool to
dress the Seat. – Ensure the Spindle Seat is clean, flat and free of any debris. – All lines must be completely flushed prior to fitting the Spindles. – The distance from the finished Wall surface to the top of the Tap Seat must be between 2 to 12mm (See diagram) – If the installation configuration is not with-in the dimensions as shown, alternative Spindles are available. Longer Spindles can be ordered from original place of purchase. Sussex Part No. SXSPEK (12mm longer than standard)
NOTE: Seat or Breech Body extensions are NOT to be used in conjunction with this Tapware. Failure to adhere will void warranty.
sussextaps.com.au
AS/NZS 3718:2005 LIC. 20081
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003 Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.