TD10043FL Flush Mount Lighting
Flush Mount Lighting
The Flush Mount Lighting is a product that can be mounted on the
ceiling. It has a fixture body (A), a PC board (B), a stem (C), a
finial (D), a canopy (E), and a mounting strap (F). It is equipped
with an E26 lamp socket and can handle a maximum power of 60W. The
input voltage required is 120V.
Product Usage Instructions
- Pass the wires through stem (C) and canopy (E) and tighten
them. - Install the bulbs (not included), then screw the PC board (B)
to the bottom nut of fixture body (A). - Fix mounting strap (F) to outlet box with screw (G).
- Connect the wires according to the wiring instruction provided
below. - Pass canopy (E) through the screw and fix it with finial
(D).
Wiring Instructions
- Insert the green grounding screw into the hole with two raised
dimples on the mounting bar. Wrap the ground wire from the fixture
(if supplied) around the green grounding screw, then connect it to
ground wire from the outlet box (if not fixed on the outlet box)
using a wire connector (not supplied). If ground wire from the
fixture is not supplied, wrap the ground wire (if not fixed on the
outlet box) from the outlet box around the green grounding screw
and tighten it. NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER
SUPPLY WIRES. - Take note of the color of the wire(s) on your fixture. Identify
which group your fixture wire(s) falls into and connect the wires
according to the directions below:
[GROUP A]: Connect to Black House Wire
[GROUP B]: Connect to White House Wire - Take your fixture wire(s) from [Group A] and place evenly
against the black wire from the outlet box. Do NOT twist wires
together before using wire connectors. - Fit a wire connector over the wires and screw the connector
clockwise until you feel firmness. - Try gently to pull the connector off the wires. If you can pull
the connector off, carefully re-do steps 3 and 4 as above, and
check again for a firm connection. - Connect the fixture wire from [Group B] to the white wire from
the outlet box in the same manner. Make sure no bare wires can be
seen outside wire connectors.
Cleaning Instructions
To clean the Flush Mount Lighting, wipe the fixture with a soft
cloth. Clean glass with a mild soap. Do not use abrasive materials
such as scouring pads or powders, steel wool, or abrasive
paper.
Safety Information
Always switch off the electricity supply and allow to cool for
10 minutes before changing the light bulbs.
Contact Information
If you have any questions or concerns about the product, please
contact us at [email protected].
Instruction Manual
Flush Mount Lighting
Overview
Outlet box Black
Wire nuts Smooth
[GROUP A] G.Screw
Green(Ground)
White Ribbed
[GROUP B]Bare copper wire(Ground)
F.Mounting strap
E.Canopy D.Finial C.Stem
A.Fixture body B.PC board
Assembly Instruction
1.Pass the wires through Stem (C) and Canopy (E) and tighten them. 2.Install the bulbs (not included), then screw the PC board (B) to
the bottom nut of Fixture body (A). 3.Fix Mounting strap (F) to outlet box with Screw (G). 4.Connect the wires according to the picture above.
(Please refer to the wiring instruction for details ) 5.Pass Canopy (E) through the screw and fix it with Finial (D).
Wiring Instruction
1. Insert the green grounding screw into the hole with two raised dimples on the mounting bar. Wrap the ground wire from the fixture (if supplied) around the green grounding screw, then connect it to ground wire from the outlet box (if not fixed on the outlet box) using a wire connector(not supplied). If ground wire from the fixture is not supplied, wrap the ground wire (if not fixed on the outlet box) from the outlet box around the green grounding screw and tighten it.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE POWER SUPPLY WIRES.
2.Take note of the color of the wire(s) on your fixture. Identify which group your fixture wire(s) falls into and connect the wires according to the directions below:
[GROUP A]: Connect to Black House Wire [GROUP B]: Connect to White House WireBLACK
WHITE
*PARALLEL WIRE (round & smooth) *PARALLEL WIRE (square & ridged)
WHITE OR GREY WITH TRACER WHITE OR GREY WITHOUT TRACER
BROWN, GOLD OR BLACK WITHOUT TRACER
BROWN, GOLD OR BLACK WITH TRACER
3.Take your fixture wire(s) from [Group A] and place evenly against the black wire from the outlet box. Do NOT twist wires together before using wire connectors. 4.Fit a wire connector over the wires and screw the connector clockwise until you feel firmness. 5.Try gently to pull the connector off the wires. If you can pull the connector off, carefully re-do steps 3 and 4 as above, and check again for a firm connection.
6.Connect the fixture wire from [Group B] to the white wire from the outlet box in the same manner. Make sure no bare wires can be seen outside wire connectors.
Product Specifications
Input voltage 120V Rated power 60W MAX Lamp socket E26
Product Packaging
Fixture body × 1 Stem × 1 PC board × 1 Mounting strap × 1 & Canopy × 1 Screw × 2 & Wire nut × 3 Lamp instruction × 1
Cleaning
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap. Do not use abrasive materials such as scouring pads or powders, steel wool or abrasive paper.
Safety Information
Always switch off the electricity supply and allow to cool for 10 minutes before changing the light bulbs.
CONTACT US
E-mail:[email protected]
Print in china