Uni-t Uti120s Professional Thermal Imager User Manual

UTi120S Professional Thermal Imager

Product Information: UTi120S Professional Thermal Imager

The UTi120S Professional Thermal Imager is a device that can
capture thermal images of objects. It has a thermal imaging sensor
that can detect infrared radiation emitted by objects and convert
it into a visible image. The device has a high thermal imaging
sensitivity, which means it can detect even small temperature
differences. It has a wide field of view and can capture images
from a minimum distance. The device can measure temperature
accurately and display it in different units. It also has features
like emissivity adjustment, laser pointer, LED light, and time/date
stamping.

Product Usage Instructions:

Before using the UTi120S Professional Thermal Imager, please
read the user manual thoroughly, especially the safety
instructions, to ensure safe and correct usage. Keep the manual in
an easily accessible place for future reference.

  1. Power On/Off: Press and hold the power button
    on the top of the device to turn it on/off.
  2. Menu: Press the menu button to access
    different settings like temperature unit, emissivity, laser
    pointer, etc.
  3. Image View: Use the arrow buttons to navigate
    through captured images.
  4. Temperature Mark: Use the cursor to select a
    specific area on the image to measure its temperature.
  5. HI/LO Alert: Set upper and lower temperature
    limits to receive alerts when the temperature exceeds or falls
    below the limits.
  6. LED Light: Press the LED button to turn on/off
    the LED light for better illumination in low light conditions.
  7. Palette: Select different color palettes for
    the thermal image.
  8. Language: Choose the language for the device
    interface.
  9. Temperature Unit: Choose the temperature unit
    (Celsius or Fahrenheit) for temperature display.
  10. Emissivity: Adjust the emissivity settings to
    get accurate temperature measurements for different materials.
  11. Laser: Use the laser pointer to mark the area
    being measured.
  12. Time & Date: Set the time and date for the
    device to stamp on captured images.
  13. Brightness: Adjust the brightness of the
    device screen for better visibility.
  14. Auto Power Off: Set a time interval for the
    device to automatically power off when not in use.
  15. Auto Save: Set the device to automatically
    save captured images to an SD card.
  16. Format SD: Format the SD card to erase all
    saved images.
  17. Device Info: View device information like
    firmware version, serial number, etc.
  18. Factory Reset: Reset the device to its default
    settings.
  19. USB Communication and PC Analysis Software:
    Connect the device to a computer using a USB cable to transfer
    captured images and use analysis software.
  20. Maintenance: Clean the lens and body of the
    device regularly with a soft cloth. Do not use water or
    chemicals.

P/N: 110401110442X

UTi41’12DS
Professional Thermal lmager

UTi120S User Manual

UNl-“‘I:

Preface
Thank you for purchasing the new UTi120S thermal imager. In order to use this product safely and correctly, please read this manual thoroughly, especially the Safety Instructions part.
After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damages caused by accident, negligence, misuse, modification, contamination or improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.
Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by using this device.

20

UNIT

UTi120S User Manual

Table of Contents

1. Specifications

22

2. Structure

24

3. LCD Indicators/Icons

25

4. Power on/off ——————————————————————— 25

5. Menu

26

6. Image View

26

7. Temperature Mark

27

8. HI/LO Alert

27

9. LED light

28

10. Palette

28

11. Language

29

12.Temperature Unit

29

13. Emissivity

30

14. Laser

30

15. Time & Date

31

16. Brightness

31

17. Auto Power Off

32

18. Auto Save

32

19. Format SD

33

20. Device Info

33

21. Factory Reset

34

22. USB Communication and PC Analysis Software ———

— 34

23. Maintenance

34

24. Safety Instructions

35

25. Appendix

35

21

UTi120S User Manual

UNl-“‘I:

1. Specifications
Sensor Pixel size Infrared spectrum bandwidth Thermal imaging pixels Thermal imaging sensitivity Field of view (FOV) Spatial resolution (IFOV) Rate Minimum imaging distance Focus Temperature range
Accuracy
Measurement units Resolution Emissivity
Temperature display

Uncooled infrared focal plane thermal imaging sensor 17µm 8~14µm 10800 (120*90)
<60mK 50° (H) X 38° (V)
7.6 mrad 25Hz 0.1m
Focus-free -20°C-400°C
2°c or2% , whichever is greater (-10°C-400°C room temperature 25°C)
C/°F 0.1° c 0.95 (default) 0.01-0.99
Center point temperature, high/low temperature tracking

Palettes
Display type Display resolution

lava , rainbow HC , black hot , white hot, iron, Rainbow
2.4” T FT LCD 320 X 240
22

UNIT

UTi120S User Manual

Buttons Laser LED Light Temperature alarms Image storage Image format PC analysis software USB communication Battery Operating time Charging time Charging voltage/current Power on speed Auto power off Operating temperature Storage temperature Operating humidity IP rating Drop proof Product size (LxWxH) Product weight Certificates
Accessories
23

4 buttons (power, up, down,OK) 1 trigger (Class 2)
LCD, LED, buzzer Micro SD Card BMP Type-C USB
Li-ion 3.7V/2600mAh 18650 Continuous operating time >9h
S2.5h 5V / 2A Os (wake up) / 5s (power on) 5min/1 Omin/30min(default)/off 0-50°C ( 32-140°F) -20-60°C ( -4-140°F) < 85%RH (Operating humidity )
IP54 2m 197 x 72 x 60 mm 310g CE UKCA RoHS
User manual, Type-C USB cable, 16GB Micr1 o SD card

UTi120S User Manual
2. Structure

UNl-“‘I:

Item Description 1 Upper housing 2 Interface protection cover 3 Lower housing 4 USB Type-C interface 5 SD card slot 6 Bracket screw hole 7 Laser emission aperture 8 LED light

Item Description 9 Infrared camera lens 10 Image capture/trigger 11 LCD 12 OK 13 Up 14 Power / Back 15 Down

24

UNIT

UTi120S User Manual

3. LCD Indicators/Icons

Display size: 2.4” (495mmx377mm) Display resolution: 320 (vertical) x 240 (horizontal)

g

5

L 2
3

I6
–7
l 1 9

Item

Description

1 Center point temperature

2 Center point

3 Lowest temperature spot

4 Date and time

5 Battery status

6 Temperature Bar

7 Highest temperature spot

4. Power On/Off
When the thermal imager is not turned on, long press the power button for 3s to power on. When the thermal imager is in the suspend state, short press the power button for 1s to power on.
When the thermal imager is turned on, short press the power button for 1s to enter the suspend state. Long press the power button for 8s, “power off’will show on the screen, and the thermal imager will be turned off.
25

UTi120S User Manual

UNl-“‘I:

5. Menu
Short press the OK button to enter the menu interface. Short press the Back button to return to the upper menu. Short press the trigger to directly return to the main interface of the thermal imager.

6. Image View
In the menu, select Image View, and then short press the OK button to enter the image viewing interface. Press the Up/Down button to select an image. Press the OK button twice to view the Picture Info or Delete images.

_,

· · IMG DDIS
– PictUieo.,. Delete

26

UNIT

UTi120S User Manual

7. Temperature Mark
In the menu, short press the Up/Down button to select Temper Mark, and then short press the OK button to enter the temperature mark interface. Center Point/ Hi/Lo Point/Palette/Date&Time can be set in this interface. For example, select Center Point, and then press the OK button to turn on/off this function.

Screen Display

$ CenterPoint

. , H1L0Po1nt

Palette

D

0 Date&T,me

8. HI/LO Alert
In the menu, short press the Up/Down button to select HI/LO Alert, and then short press the OK button to enter the alert setting interface. Temper Alert, Buzzer, HI Alert and LO Alert can be set in this interface.

UTi120S User Manual

UNl-“‘I:

9. LED light
In the menu, short press the Up/Down button to select Hand Light, and then short press the OK button to turn on/off the flashlight.

10. Palette
In the menu, short press the Up/Down button to select Palette, and then short press the OK button to enter the palette selection interface. Short press the Up/Down button to step through six palettes: Rainbow, Iron, White Hot, Black Hot, Rainbow HC, Lava, and short press the OK button to confirm the selected palette.

27

28

UNIT

UTi120S User Manual

11.Language
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. Select Language, and short press the OK button to switch between English/Chinese.

Menu lmageV,ew

0 Screen Display

I,J: HI/LO Alert

LED light

e

Q Palette

£Em,ss,v,ty

6. Laser

0

T,mc&Date

C Brightness

Auto Power Off >

12. Temperature Unit
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/Down button to select Temper Unit, and short press the OK button to switch between·c /”F.

TempUn

‘C

o

‘F

o

29

UTi120S User Manual

UNl-“‘I:

13. Emissivity
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Emissivity, and short press the OK button to set the emissivity.

14. Laser
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Laser, and short press the OK button to turn on/off the laser.

)

)

30

UNIT

UTi120S User Manual

15. Time & Date
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Time&Date, and short press the OK button to enter the setting interface. The Time Format can switch between 12H and 24H. Press the Up/Down button to adjust the value of time and date, and short press the OK button to confirm.

< Time&Date

TimeFormat

12H

Time

05:02 PM

Date

2021.08.31

< Time&Date

T,meFormat

12H

Time

05:02 PM

Date

1011.08.31

16. Brightness
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Brightness, and short press the OK button to enter the setting interface. The brightness can be Low, Middle or High

Brightness

Low

o

Middle

o

High

o

31

UTi120S User Manual

UNl-“‘I:

17. Auto Power Off
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Auto Power Off, and short press the OK button to enter the setting interface. In this interface, users can set the auto power off time (5/ 10/30min) or turn off the auto power off function.

0
0
0
r 0
18. Auto Save
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Auto Save. Short press the OK button to turn on/off the auto save function.

32

UNIT

UTi120S User Manual

19. Format SD
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Format SD and short press the OK button to enter the setting interface. Press the OK button select Yes or No.

UTi120S User Manual

UNl-“‘I:

21. Factory Reset
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Factory Reset and short press the OK button to enter the setting interface. Press the OK button select Yes or No.

20. Device Info
In the menu, short press the Up/Down button to select Setting, and then short press the OK button to enter the submenu. In the submenu, short press the Up/ Down button to select Device Info and short press the OK button to enter the information viewing interface. T he device information including Code, Firmware, Capacity and Available can be viewed.

< Device Info

“” Model

UT,1205

0rm ware

Vl.9

Capacity 14830MB

Available 14812MB

33

22. USB Communication and PC Analysis Software
1. Please refer to the instructions to download and install the PC software. 2. Connect the USB data cable to the computer. Users can view images and
analyze data via the PC software. 3. To use the PC software correctly, please read the Software User Manual. 4. During USB communication, do not directly unplug the USB cable. If users
want to disconnect the device when it has been successfully connected to the computer, they can select Remove Device in the lower right corner of the computer.
23. Maintenance
Use a wet cloth or weak soap solution to clean the outer shell of the device. Do not use abrasives, isopropyl alcohol or solvents to clean the outer shell, lens or window.
34

UNIT

UTi120S User Manual

24. Safety Instructions
In order to ensure the measurement accuracy, please read the instructions carefully. Please use this product in accordance with the user manual. Otherwise the free warranty will not be carried out if the product is damaged. Please do not use this product in flammable, explosive, steamy, humid or corrosive environments. Please do not continue to use the product when it is damaged, dropped or corrected, so as to avoid erroneous measurement results. Please refer to the emissivity to get the actual temperature. Otherwise the measured temperature will be inaccurate. Charging will cause the internal temperature of the machine to rise, thereby affecting the measurement accuracy. Therefore, it is recommended not to take measurements when charging the product.

25. Appendix
Material Wood Water Brick Stainless steel Adhesive tape Aluminum plate Copper plate Black aluminum Human skin Asphalt PVC plastic

Emissivity 0.85 0.96 0.75 0.14 0.96 0.09 0.06 0.95 0.98 0.96 0.93

Material Black paper Polycarbonate Concrete Copper oxide Cast iron Rust Gypsum Paint Rubber Soil

Emissivity 0.86 0.8 0.97 0.78 0.81 0.8 0.75 0.9 0.95 0.93

35

UTi120S User Manual

UNl-“‘I:

UNIT
UNI-TRENTECHNLGV (CHINA) CO., LT
No.6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone, Dongguan City, Guangdong Province, China

<ii·

36

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals