Planet Iecj-300 Industrial Ethercat Junction Slave User Manual

IECJ-300 Industrial EtherCAT Junction Slave

Product Information

The Industrial EtherCAT Junction Slave series, also known as
IECJ series, is a versatile networking device designed for
industrial applications. It provides seamless connectivity and
communication between EtherCAT devices in a network. The series
includes three models:

  • IECJ-300: Industrial 3-Port EtherCAT Junction Slave with 3 x
    100BASE-TX RJ45 ports (1 IN and 2 OUT).
  • IECJ-400: Industrial 4-Port EtherCAT Junction Slave with 4 x
    100BASE-TX RJ45 ports (1 IN and 3 OUT).
  • IECJ-410FT: Industrial 3-Port RJ45 + 1-Port SFP EtherCAT
    Junction Slave with 3 x 100BASE-TX RJ45 ports (1 IN and 2 OUT) and
    1 x 100BASE-FX SFP slot (OUT).

The package contents of the IECJ series include:

  • The Industrial EtherCAT Junction Slave device itself.
  • A QR Code Sheet for easy access to online resources.
  • A wall-mount kit for convenient installation.
  • Copper dust caps to protect the ports when not in use.
  • SFP dust caps for the IECJ-410FT model.

It is important to check the package contents upon receipt. If
any item is missing or damaged, please contact your dealer
immediately and retain the original packaging material for
potential return or repair.

Product Features

  • Physical ports:
    • IECJ-300: 3 x 100BASE-TX RJ45 ports (1 IN and 2 OUT).
    • IECJ-400: 4 x 100BASE-TX RJ45 ports (1 IN and 3 OUT).
    • IECJ-410FT: 3 x 100BASE-TX RJ45 ports (1 IN and 2 OUT) and 1 x
      100BASE-FX SFP slot (OUT).
  • LED indicators for input status.
  • Wide input voltage range of 9 ~ 48V DC.
  • Supports EtherCAT distributed clock (DC) mode.
  • EtherCAT conformance test tool verified.

Product Specifications

ModelCommunication InterfaceCopper Distance between StationsData Transfer Medium100BASE-FX SFP slotFiber Distance between StationsData Transfer MediumPower Input Voltage RangePower ConsumptionDimensions (W x D x H)InstallationCase MaterialOperating TemperatureStorage TemperatureRelative Humidity
IECJ-3003 (1 in/2 out)max. 100 m (100BASE-TX)Shielded Ethernet/EtherCAT cable (min. cat5)9~48V DCMax. 1.44W33x70x104mmDIN-rail mounting and wall mountingIP30 metalOperating: -40°C ~ 75°CStorage: -40°C ~ 85°C5% ~ 95% (non-condensing)
IECJ-4004 (1 in/3 out)max. 100 m (100BASE-TX)Shielded Ethernet/EtherCAT cable (min. cat5)9~48V DCMax. 2.44W32x87x135mmDIN-rail mounting and wall mountingIP30 metalOperating: -40°C ~ 75°CStorage: -40°C ~ 85°C5% ~ 95% (non-condensing)
IECJ-410FT3 (1 in/2 out)max. 100 m (100BASE-TX)Shielded Ethernet/EtherCAT cable (min. cat5)1 (1 out)Depending on the ability of SFP moduleEtherCAT9~48V DCMax. 2.83W32x87x135mmDIN-rail mounting and wall mountingIP30 metalOperating: -40°C ~ 75°CStorage: -40°C ~ 85°C5% ~ 95% (non-condensing)

Hardware Introduction

The hardware of the Industrial EtherCAT Junction Slave series
features multiple 100BASE-TX RJ45 copper ports or a 100BASE-FX SFP
slot (for IECJ-410FT), along with a removable 4-pin power terminal
block. The LED indicators are located on the front panel for easy
monitoring. Refer to the user manual for detailed illustrations of
the front panel and LED indicators.

The Industrial EtherCAT Junction Slave series supports both
DIN-rail mounting and wall mounting, providing flexibility in
installation. The case is made of IP30-rated metal material,
ensuring durability and protection.

Please refer to the user manual for detailed installation
instructions and other hardware-related information.

Industrial EtherCAT Junction Slave
IECJ-300/IECJ-400/IECJ-410FT User’s Manual

Table of Contents
1. Package Contents……………………………………………………………………… 3 2. Product Features ………………………………………………………………………. 4 3. Product Specifications ………………………………………………………………… 5 4. Hardware Introduction ……………………………………………………………….. 6
4.1 Three-View Diagram…………………………………………………………….. 6 4.2 Wiring the Power Inputs……………………………………………………….. 9 4.3 Grounding the Device …………………………………………………………. 11 5. Installation ……………………………………………………………………………. 12 5.1 DIN-rail Mounting Installation ………………………………………………. 12 5.2 Wall-mount Plate Mounting ………………………………………………….. 13 5.3 Side Wall-mount Plate Mounting……………………………………………. 13 6. Getting Started ………………………………………………………………………. 14 6.1 Connecting the Power and the Host PC…………………………………… 14 6.2 Configuration and Operation ………………………………………………… 16 Customer Support………………………………………………………………………… 18

1. Package Contents

Thank you for purchasing PLANET Industrial EtherCAT Junction Slave series. The descriptions of these models are as follows:

IECJ-300 IECJ-400 IECJ-410FT

Industrial 3-Port EtherCAT Junction Slave Industrial 4-Port EtherCAT Junction Slave Industrial 3-Port RJ45 + 1-Port SFP EtherCAT Junction Slave

“EtherCAT Junction Slave” or “IECJ series” is used as an alternative name in this user’s manual.
Open the box of IECJ series and carefully unpack it. The box should contain the following items:

Item

Model Name

The Industrial EtherCAT Junction Slave

QR Code Sheet

Wall-mount Kit

Copper Dust Cap

SFP Dust Caps

IECJ-300 IECJ-400 IECJ-410FT

3

4

3

1

If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.

3

2. Product Features
z Physical port IECJ-300: 3 x 100BASE-TX RJ45 port; 1 IN and 2 OUT IECJ-400: 4 x 100BASE-TX RJ45 port, 1 IN and 3 OUT IECJ-410FT: 3 x 100BASE-TX RJ45 port; 1 IN and 2 OUT 1 x 100BASE-TF SFP slot; it is OUT
z LED indicators for the input status z 9 ~ 48V DC wide input voltage range z Supports EtherCAT distributed clock (DC) mode z EtherCAT conformance test tool verified
4

3. Product Specifications

Model

IECJ-300

IECJ-400

IECJ-410FT

Communication Interface

100BASE-TX RJ45 Port

3 (1 in/2 out)

4 (1 in/3 out)

3 (1 in/2 out)

Copper Distance between Stations

max. 100 m (100BASE-TX)

Data Transfer Medium

Shielded Ethernet/EtherCAT cable (min. cat5)

100BASE-FX SFP slot

1 (1 out)

Fiber

Distance between Stations
Data Transfer Medium

Depending on

the ability of

SFP module

EtherCAT

Protocol

Ether CAT

Power

Input Voltage Range

9~48V DC

Power Consumption Mechanical

Max. 1.44W Max. 2.44W Max. 2.83W

Dimensions (W x D x H) Installation

33x70x104mm

32x87x135mm

DIN-rail mounting and wall mounting

Case Material

IP30 metal

Environment

Operating Temperature Storage Temperature Relative Humidity

-40~75°C -40~85°C 5~95% (non-condensing)

5

4. Hardware Introduction
This section describes the hardware features and installation of the Industrial EtherCAT Junction Slave series. To easily manage the Industrial EtherCAT Junction Slave, familiarize yourself with its display indicators and ports. Front panel illustrations in this chapter display the LED indicators.
4.1 Three-View Diagram
The three-view diagram of the Industrial EtherCAT Junction Slave series consists of multiple 100BASE-TX RJ45 copper ports or one 100BASE-FX SFP slot (for IECJ-410FT), and one removable 4-pin power terminal block. The LED indicators are also located on the front panel. IECJ-300
Top View

V1+

PWR1 PWR2

V2+

DC Input: 9-48V , 0.6A max.

Side View

104.00 30.00
30.00 50.00

Front View
P1 P2 Run
LNK ACT IN
1 OUT
2 OUT
3 IECJ-300
Bottom View

70.00

Side View

28.65

21.69

52.00

52.00

Rear View

Mounting Kit

40.00 18.00

DIN-Rail Kit

147.00 48.80
91.00 9.00

28.00

40.00

18.00

18.00

Mounting Kit
Unit: mm

6

IECJ-400

Side View

Front View

15.20

P1 P2 Run
1 2 3 4 LNK ACT

IN

1

OUT

2

OUT

3

OUT

4

IECJ-400

32.00

IECJ-410FT

Side View

Front View

15.20

P1 P2 Run
1 2 3 4 LNK ACT

IN

1

OUT

2

OUT

3

LNK/ ACT

SFP OUT 4

100BASE-FX IECJ-410FT

32.00

135.00

9.20

135.00

9.20

DC Input: 9-48V , 0.6A max.

DC Input: 9-48V , 0.6A max.

V2+

PWR1 PWR2

V2+

PWR1 PWR2

97.10 87.80

97.10 87.80

Top View Side View
Bottom View Top View Side View
Bottom View

V1+

V1+

39.70

48.80

46.50

39.70

48.80

46.50

18.00

18.00

53.50

53.50

53.50

53.50

18.00 28.00

28.00

28.00 18.00

18.00 28.00

28.00

28.00 18.00

Mounting Kit Rear View
DIN-Rail Kit
Mounting Kit
Unit: mm
Mounting Kit Rear View
DIN-Rail Kit
Mounting Kit
Unit: mm
7

28.00

48.80

28.00

28.00

48.80

28.00

40.00

40.00

40.00

40.00

163.00

163.00

Front View IECJ-300
P1 P2 Run
LNK ACT IN
1

IECJ-400
P1 P2 Run
1 2 3 4 LNK ACT

IN

1

IECJ-410FT
P1 P2 Run
1 2 3 4 LNK ACT

IN

1

OUT
2

OUT

2

OUT

2

OUT
3

OUT

3

OUT

3

IECJ-300

OUT

4

LNK/ ACT

SFP OUT 4

IECJ-400

100BASE-FX
IECJ-410FT

LED Definition:
System

LED P1 P2
Run

Color

Function

Green Lights to indicate power 1 has power.

Green Lights to indicate power 2 has power.

Light

The device is in the state of operation.

Green

Single Flash
Blinking

The device is in the state of operation without risk.
The device is ready to be operated.

Off

The device is in the initialization mode

8

100BASE-TX RJ45 Port (Port Input/Port Output)

LED

Color

Function

Light

Indicating that the port is linked up.

Indicating that the module is actively sending LNK/ACT Green Blinking or receiving data over that port.

Off

Indicating that the port is linked down.

100BASE-FX SFP Port (Port Output) *IECJ-410FT only

LED

Color

Function

Light

Indicating that the port is linked up.

Indicating that the module is actively sending LNK/ACT Green Blinking or receiving data over that port.

Off

Indicating that the port is linked down.

4.2 Wiring the Power Inputs
The 4-contact terminal block connector on the top panel of Industrial EtherCAT slave I/O module is used for one DC power input. Please follow the steps below to insert the power wire.

When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock.
1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER.
IECJ-300

1 2 3 4

V1+

V2+

PWR1 PWR2

DC Input: 9-48V , 0.6A max.

9

Top View IECJ-400/IECJ-410FT

1 2 3 4

V1+

V2+

PWR1 PWR2

DC Input: 9-48V , 0.6A max.

2. Tighten the wire-clamp screws for preventing the wires from loosening.

1234 Power1 Power2 V1+ V1- V2+ V2-
1. The DC power input range is 9-48V DC. 2. The device provides input voltage polarity protection.
PWR1 and PWR2 must provide exactly the same DV voltage for power load balance while operating with dual power input.

10

4.3 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device.
IECJ-300

1 2 3 4

V1+

V2+

PWR1 PWR2

DC Input: 9-48V , 0.6A max.

IECJ-400/IECJ-410FT

Earth Ground

1 2 3 4

V1+

V2+

PWR1 PWR2

DC Input: 9-48V , 0.6A max.

Earth Ground

EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRANTY.

11

5. Installation
This section describes the functionalities of the Industrial EtherCAT slave I/O module’s components and guides you to installing it on the DIN rail and wall. Please read this chapter completely before continuing.
This following pictures show the user how to install the device, and the device is not IECJ series.
5.1 DIN-rail Mounting Installation
1 2
12

5.2 Wall-mount Plate Mounting
5.3 Side Wall-mount Plate Mounting
You must use the screws supplied with the wall-mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.
13

6. Getting Started
This chapter provides a basic overview of how to configure and operate your IECJ series.

6.1 Connecting the Power and the Host PC

Step 1:

Connect both the Port 1 of the IECJ series and RJ45 Ethernet port of Host PC. Ensure that the network settings on the Host PC have been correctly configured and are functioning normally. Ensure that the Windows firewall and any anti-virus firewall are properly configured to allow incoming connections; if not, temporarily disable these functions.

Attaching an ESC (EtherCAT Slave Controller) directly to an office network will result in network flooding, since the ESC will reflect any frame ­ especially broadcast frames ­ back into the network (broadcast storm).

Step 2: Apply power to the IECJ series (Take the IECJ-300 for an example)

Connect the Host device to the IN Port on IECJ-300
IN
PC

9-48V

V+

DC

V+

V+

+

Connect the V+ pin to positive terminal on a 9-48V DC power supply, and connect the V- pin to the negative terminal.

14

Step 3: Verify the “P1” LED indicator on the IECJ series module is Green; “Port 1” LED indicator is Green.

IN

Run
TP IN
LNK ACT
LNK/ SFP OUT
ACT
100BASE-FX
IEIECCCJ–23100T

P1 P2

15

6.2 Configuration and Operation
Beckhoff TwinCAT 3.x is the most commonly used EtherCAT Master software to operate the IECJ series. Click on the link below to download Beckhoff TwinCAT 3.x: https://www.beckhoff.com/en-en/support/download-finder/software-and-tools/
Inserting into the EtherCAT network Installation of the latest XML device description (ESI). Make sure to use the latest installation description to install the latest XML device. This can be downloaded from PLANET website (https://www.planet.com.tw/en/support/downloads?&m ethod=keyword&keyword=IECJ) and check the online FAQs for the installation of the XML device.
16

Step 1: Automatic Scanning z The EtherCAT system must be in the safe, de-energized state before the
IECJ series module is connected to EtherCAT network. z Switch on the operating voltage, open the TwinCAT System Managed (Config
mode), and scan the devices as shown in the print screen instructions below. Acknowledge all dialogs with “OK”, so that the configuration is in the “FreeRun” mode.
Step 2: Configuration via TwinCAT In the left-hand window of the TwinCAT System Manager, click on the brand of the EtherCAT Box you wish to configure (Take the IECJ-300 for an example). Click Box 1 to get and configure state.
17

Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: http://www.planet.com.tw/en/support/faq.php Support team mail address: [email protected]
Copyright © PLANET Technology Corp. 2023. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
18

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals