90057 Ground Mount Kits
Ground Mount Kits
The Ground Mount Kits are a low-cost rail-based PV module
mounting system that provides easy installation, simple wire
management, great strength, and economical shipping structure. The
PV cables and wiring for module-level electronics fit inside rails
to avoid time-consuming wire management. All components meet the UL
standards and have a Class A Fire Rating for Type 1 and 2 modules.
Pre-stamped engineering letters are available for most states.
Tamarack Ground Mount Kit Sizing
Kits are available for systems with either 3 or 4 modules per
column. Use a First Column Kit and up to 7 Add-On Kits. Find the
wind speed and snow load required for your location and tilt angle.
Green or yellow boxes on the chart note compatibility with 60 cell
or 72 cell modules. Orange squares note compatibility with 60 cell
modules only. Red boxes require custom mount design. Yellow and
orange boxes require North/South cross braces. Order one Cross
Brace Tee per vertical post.
No Bracing Required Use Cross Bracing 60 Cell Modules Only 3
rail per column Maximum Wind Rating (MPH) Column Snow Tilt 100 110
120 130 140 150 160 170 Height Load (psf) Angle
The sizing chart is based on Exposure Category B, which includes
urban and suburban or wooded areas. Obstructions the size of
single-family dwellings must surround the mount location within 1/2
mile in all directions. For flat, open country or hurricane-prone
regions, please contact us before purchasing.
Item # Kits
| Description | Kit Type |
|---|---|
| 3 Module First Column Kit – (4) 66 rails, (4) 2 Tee-Fittings, (2) Splices, (4) Pipe Mounts, (8) 5050 Clamps, (4) End Caps, (8) Module Lead Clips and (1) Ground Clamp | 3 Module Per Column |
| 3 Module Add-On Column Kit – (4) 66 rails, (2) 2 Tee-Fittings, (2) Splices, (4) Pipe Mounts, (8) 5050 Clamps, (4) End Caps, (8) Module Lead Clips | 3 Module Per Column |
| 4 Module First Column Kit – (4) 85 rails, (4) 2 Tee-Fittings, (2) Splices, (4) Pipe Mounts, (10) 5050 Clamps, (4) End Caps, (8) Module Lead Clips and (1) Ground Clamp | 4 Modules Per Column |
| 4 Module Add-On Column Kit – (4) 85 rails, (2) 2 Tee-Fittings, (2) Splices, (4) Pipe Mounts, (10) 5050 Clamps, (4) End Caps and (8) Module Lead Clips | 4 Modules Per Column |
| Cross Brace Tee | 2-inch Swivel Tee-Fitting for cross bracing. Use 1 for each vertical post when bracing is required. |
Product Usage Instructions
- Determine the number of modules per column and choose the
appropriate kit type. - Use a First Column Kit and up to 7 Add-On Kits to install the
mounting system. - Find the wind speed and snow load required for your location
and tilt angle. - Refer to the sizing chart to determine compatibility with your
module type and whether cross bracing is required. - If cross bracing is required, order one Cross Brace Tee per
vertical post. - Install the rails, Tee-Fittings, Splices, Pipe Mounts, Clamps,
End Caps, Module Lead Clips, and Ground Clamp according to the
instructions provided in the kit.
GROUND MOUNT KITS
Save Time and Money Low-cost rail-based PV module mounting system
provides easy installation, simple wire management,
great strength and economical shipping
· Utilizes our heavy-duty 3.1 mill finish rail · Kits contains all parts required except 2-inch schedule 40 pipe
and concrete · UPS shippable · Choose one starter kit for first column of
3 or 4 modules · Expand with up to 7 add-on column kits · Mount up to 64 modules on a single
structure.
· Mount 60 or 72 cell modules with frame thickness between 30mm and 40mm
· Rated for up to 170 MPH wind speed and 50 psf of snow load
· Some situations require cross bracing – see sizing chart on next page · Sites with greater than 15 degree slope may require additional engineering
certification · Maximum module width 43″ on 3-module kits and 41.6″ on 4-module kits
Best Wire Management – PV cables and wiring for module-level electronics fits inside rails to avoid time consuming wire management.
UL 2703 Listed – All components meet the UL standards and have a Class A Fire Rating for Type 1 and 2 modules.
PE Certified – Pre-stamped engineering letters available for most states.
Ground Mount Kits Rev 3
2/23/2023
Tamarack Ground Mount Kit Sizing
Kits are available for systems with either 3 or 4 modules per column. Use a First Column Kit and up to 7 Add-On Kits. Find the wind speed and snow load required for your location and tilt angle. Green or yellow boxes on the chart at right note compatibility with 60 cell or 72 cell modules. Orange squares note compatability with 60 cell modules only. Red boxes require custom mount design. Yellow, orange boxes require North/South cross braces. Order one Cross Brace Tee per vertical post.
No Bracing Required Use Cross Bracing 60 Cell Modules Only 3 rail per column
Maximum Wind Rating (MPH)
Column Snow Tilt 100 110 120 130 140 150 160 170
Height Load (psf) Angle
20
20
30
40
20
3 Modules 30
30
in
40
Landscape
20
Orientation 40
30
40
20
50
30
40
20
20
30
40
20
4 Modules 30
30
in
40
Landscape
20
Orientation 40
30
40
20
50
30
40
Sizing Chart above is based on Exposure Category B. This includes urban and suburban or wooded areas. Obstructions the size of single family dwellings must surround the mount location within 1/2 mile in all directions.
For flat, open country or hurricane prone regions, please contact us before purchasing.
Item # Kits 90057 90064 Kits 90071 90088
89778
3 Module Per Column
Description
3 Module First Column Kit – (4) 66″ rails, (4) 2″ Tee-Fittings, (2) Splices, (4) Pipe Mounts, (8) 5050 Clamps, (4) End Caps, (8) Module Lead Clips and (1) Ground Clamp
3 Module Add-On Column Kit – (4) 66″ rails, (2) 2″ Tee-Fittings, (2) Splices, (4) Pipe Mounts, (8) 5050 Clamps, (4) End Caps, (8) Module Lead Clips
4 Modules Per Column
4 Module First Column Kit – (4) 85″ rails, (4) 2″ Tee-Fittings, (2) Splices, (4) Pipe Mounts, (10) 5050 Clamps, (4) End Caps, (8) Module Lead Clips and (1) Ground Clamp
4 Module Add-On Column Kit – (4) 85″ rails, (2) 2″ Tee-Fittings, (2) Splices, (4) Pipe Mounts, (10) 5050 Clamps, (4) End Caps and (8) Module Lead Clips
Cross Brace Tee 2-inch Swivel Tee-Fitting for cross bracing. Use 1 for each vertical post when bracing is required.