Minka Lavery 2692-115 Wall Sconce Installation Guide

2692-115 Wall Sconce

Product Information

The product is a light fixture (Item#2692-115) that comes with a
mounting plate, screws, and other necessary hardware. It requires
two candelabra base bulbs up to 60 watts each or CFL or LED
equivalent (not included). The fixture has a glass shade (K), a
decorative part (L), and a fixture body (F). The installation
manual also includes illustrations (Fig.1 and Fig.2) for
reference.

Product Usage Instructions

  1. Shut off power at the fuse box or circuit breaker box before
    starting the installation process.
  2. Remove the old fixture and its mounting hardware.
  3. Unpack the new fixture and make sure all parts are
    present.
  4. Remove the mounting plate (A) from the fixture body (F) by
    loosening screws (E).
  5. Remove the decorative part (L) from fixture body (F) by
    loosening screws (G).
  6. Insert glass shade (K) into decorative part (L) and secure with
    screws (G) and bushing (J).
  7. Install two candelabra base bulbs (H) or CFL or LED equivalent
    up to 60 watts each, according to the fixture specification. Do not
    exceed the maximum wattage rating.
  8. Place the glass assembly over fixture body (F) and fasten with
    screws (G).
  9. Position mounting plate (A) on the wall and mark the location
    of two drywall anchors (B). Pre-drill the holes for the drywall
    anchors (B). Insert the drywall anchors (B) into the wall.
  10. Attach mounting plate (A) to the junction box using mounting
    screws (D). The side of the mounting plate (A) marked GND must face
    out.
  11. Place woodscrews (C) through holes into the drywall anchor (B)
    to secure mounting plate (A) as shown in Fig.1.
  12. Connect the electrical wires as shown in Fig. 2, making sure
    that all wire connectors are secured. If your outlet box has a
    ground wire (green or bare copper), connect the fixture’s ground
    wire to it. Otherwise, connect the fixture’s ground wire directly
    to the mounting plate (A) using the green screw provided.
  13. Place fixture body (F) over mounting plate (A) and secure with
    screws (E).
  14. Turn on power and test the fixture.

INSTALLATION INSTRUCTIONS

Item#2692-115 (New. 02/25/2022)

READ AND SAVE THESE INSTRUCTIONS
W AR N I N G ! S HU T P O WE R O F F AT F U S E O R CI R C UI T B R E AK E R .

AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

MOUNTING THE FIXTURE (Fig.1)
1. Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
2. Carefully unpack your new fixture and lay out all the parts in a clear area. Take care not to misplace any small parts necessary for installation.
3. Loosen screws (E) to remove mounting plate (A) from fixture body (F).
4. Loosen screws (G) to remove decorative part (L) from fixture body (F).
5. Place glass shade (K) into decorative part (L). Then secure with screws (G) and bushing (J) (Do not over tighten).
FINISHING THE INSTALLATION (Fig.1)
6. Install (2) two candelabra base bulbs (H) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification. –DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)
7. Place glass assembly over fixture body (F) and fasten with screws (G).
8. Position mounting plate (A) on the wall and mark the location of two drywall anchors (B). Pre-drill the holes for the drywall anchors (B). Insert the drywall anchors (B) into the wall.
9. Attach mounting plate (A) to the junction box (not included) using mounting screws (D). The side of the mounting plate (A) marked “GND” must face out.
10. Place woodscrews (C) through holes into the drywall anchor (B) to secure mounting plate (A) as shown in Fig.1.
CONNECTING THE WIRES (Fig. 2)
11. Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors are secured. If your outlet box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the mounting plate (A) using the green screw provided. After the wires are connected, tuck them carefully inside the junction box.
12. Place fixture body (F) over mounting plate (A) and secure with screws (E).
Your installation is now complete. Return power
and test the fixture.

Fig. 1
Set#A-021-175350 -Mounting plate -Ground screw – Mounting screw*2

B A
D

C G

Fig. 2
FIXTURE WIRES Black or Smooth

FIXTURE WIRES White or Ribbed

H

E F G

J K

L

FIXTURE WIRES Green or Bare Copper (Ground)

Note: Illustration (Fig.1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.

HOUSE WIRES Black (Hot)

HOUSE WIRES White (Neutral)

HOUSE WIRES Green (Ground)

MIN 75 SUPPLY CONDUCTORS

LA-3518E