GEM Easiprox Plus Series Access Control Proximity Readers
Product Information:
The Easiprox+ Series is a range of access control proximity
readers. It includes two models: Easiprox+ and Easiprox+ Slim. The
Easiprox+ reader has dimensions of 114mm (L) x 80mm (W) x 18mm (D)
and comes in navy blue color. The Easiprox+ Slim reader has
dimensions of 88mm (L) x 44mm (W) x 23mm (D) and comes in black
color.
Features:
- Easiprox+
- Easiprox+ Slim
Specifications:
- Easiprox+
- Dimensions: 114mm (L) x 80mm (W) x 18mm (D)
- Color: Navy Blue
- Easiprox+ Slim
- Dimensions: 88mm (L) x 44mm (W) x 23mm (D)
- Color: Black
Parts List:
For Easiprox+ Series:
- Anchor bolts x4
- Crimp connectors x12
- Cards x2
- Key fob x1
- Security Screw (Spanner flat head screw) x1 – Size: 4x13mm
- Spanner screwdriver x1
- LED & Audible Indicators
For Easiprox+ Slim:
- Flat head Phillips screws, Cone point – Size: 4x25mm x4
- Three-point screwdriver (Special tool) x1
- LED & Audible Indicators
LED & Audible Indicators:
- LED Colors:
- Blue – Status: Power on, Standby mode
- Green – Status: Unlocked, Door always unlocked
- Red – Status: Invalid access, Door always locked
- Audible Beeps:
- 1 Long beep – Status: Valid access, Reset is completed
- 2 Short beeps – Status: Login completed
- 3 Short beeps – Status: Invalid access
- Constant beeping – Status: Bluetooth device vandalized, Door
sensor is on
Easiprox+ Series Wiring Diagram:
Note: Easiprox+ Slim has the same wiring and pin setting.
- P1 – Green
- P2 – Green
- Buzzer – Brown
- P3 – Brown
Reset Procedures:
- Power off Access Control Reader.
- Move the Pin Jumper to P2 and P3, then power on.
- Hear a long beep to complete resetting procedures.
- Move the Pin Jumper back to P1 and P2 to Normal setting.
- Login as Admin and check all users, audit trail events are all
cleared and everything is reset to factory default setting, except
device name.
Product Usage Instructions:
Install Crimp Connectors:
Crimp connectors are included with the product. Follow these
steps to install them:
- Use a pair of crimping pliers designed for insulated
connectors. - Place the crimp connector into the compression slot.
- Ensure that the crimping jaws are positioned over the stripped
portion of the wire. - Squeeze the handles together with enough force to crush the end
of the butt splice.
Easiprox+ Reader Installation:
Follow these steps to install the Easiprox+ reader:
- Check and measure the dimensions.
- Connect the wires and mount the back cover using 4 anchor
screws into the wall. - Install the front cover, then install the bottom security
screw. Finish installation.
Easiprox+ Slim Reader Installation:
Follow these steps to install the Easiprox+ Slim reader:
- Check and measure the dimensions.
- Connect the wires and mount the base using 4 anchor screws into
the wall. - Use 4 screws to mount PCB case and the base.
- Connect PCB Case and Front cover, then install the bottom
security screw. Finish installation.
Software App Operations:
- Download the Easiprox App (for models Easiprox+ Series and DG
Series). - Scan the QR Code or download the App from the Apple Store or
Google Play, depending on your smartphone. - Smartphone compatibility: Android 5.0 and up, iOS 9.0 and
up.
Easiprox+ Series
Access Control Proximity Readers
Easiprox+
Easiprox+ Slim
Features:
· Applicable card modej EM Card / Key Fob
· 1 Administrator and 200 Users · 200 Proximity Cards / Key fobs · Access ModesUse Bluetooth smartphone
or Card / Key fob to access · Built-in Tamper alarm and Buzzer (85dB) · User ManagementjAdd / Delete / View
user data, Grant user access for specific dates or time periods, Change user passcode · Audit Trail logs for last 1000 events · Alarm output to notify that Tamper alarm has been triggered · Overhead LEDs for easy use in the dark · IP65
Specificaons:
· Operating Voltagej Easiprox+ Slim: 12VDC
Easiprox+: 12/24VDC · Bluetooth ModulejBLE 4.2 Bluetooth Low Energy · Current Draw
Easiprox Slim+: Standby current89mA@12VDC Working current (Relay active)103mA@12VDC Easiprox+: Standby current53mA@12VDC, 30mA/24VDC Working current (Relay active)60mA@12VDC, 34mA@24VDC · Read Rangej5cm · FrequencyjEM 125KHz · Operating DistancejUp to 50 meters (164 ft) without blocking by metal or concrete wall / door
frames · Smartphone CompatibilityjAndroid 5.0 and up,
iOS 9.0 and up · FinishjABS · Temperaturej-20 °C ~ 70 °C (-4 °F ~158 °F) · Dimension / Colorj
Easiprox+j114 (L) x 80 (W) x 18 (D) mm / Navy Blue Easiprox+ Slimj88 (L) x 44 (W) x 23 (D) mm / Black
1
Easiprox+ Series Pre-Installaon
Please check Parts Listj
For Easiprox+ Series Parts
Anchor bolts x4
Crimp connectors x12
Cards x2
For Easiprox+ Screw Packs
Key fob x1
Security Screw (Spanner flat head screw) x1
4x13mm
Spanner screw driver x1 For Easiprox+ Slim Screw Packs
Flat head phillips screws, Cone point 4x25mm
x4
Three-point screwdriver (Special tool)
x1
LED & Audible Indicators
Three-point security Screw
x1
Pan
head phillips screws, Cone point
x4
LED Blue Green Red
Status Power on, Standby mode Unlocked, Door always unlocked Invalid access, Door always locked
Easiprox+ Series Wiring Diagram
Audible Beeps
Status
1 Long beep
Valid access, Reset is completed
2 Short beeps Login completed
3 Short beeps Invalid access
Constant beeping Bluetooth device vandalized, Door sensor is on
(Easiprox+ & Easiprox+ Slim have same wiring and pin seng)
Easiprox+
Cable
Easiprox+ Slim
P1 P2 Buzzer P3
Green Green Brown
P1 Buzzer P2
P3
Cable
Brown Yellow White
Blue
Jumper Pin Seng : : Normal (P1,P2)
P1P2P3 (Default)
: Reset (P2,P3)
P1P2P3
Black (Polarity
Insensi ve)
Red
Orange
Orange
RTE (Request-To-Exit) RTE (Request-To-Exit) DS (Door Sensor) DS (Door Sensor) NC (Fail-Safe Electrified Lock) COM NO (Fail-Secure Electrified Lock) V- (Power Supply) V+ (Power Supply) ALM (Alarm Output) ALM (Alarm Output)
Reset Procedures
1. Power off Access Control Reader. 2. Move the Pin Jumper to P2 and P3, then power on. 3. Hear a long beep to complete resetting procedures. 4. Move the Pin Jumper back to P1 and P2 to Normal setting. 5. Login as Admin and check all users, audit trail events are all cleared and everything is reset to factory
default setting, except device name.
2
Install Crimp Connectors
Crimp connectors included:
Crimp connectors
Use a pair of crimping pliers designed to crimp insulated connectors. Place the crimp connector into the compression slot. Be sure the crimping jaws are positioned over the stripped portion of the wire. Squeeze the handles together with enough force to crush the end of the butt splice.
Easiprox+ Reader Installaon:
Easiprox+
Easiprox+ Slim
Front Cover
PCB Case
Easiprox+ Slim Front Cover
Security Screw
Back Cover
Easiprox+
Base
Security Screw
1. Check and measure dimensions. 2. Connect the wires and mount the back cover
by using 4pcs of anchor screws into the wall. 3. Install the front cover then install the bottom
security screw. Finish installation.
So[ware App Operaons
1. Check and measure dimensions. 2. Connect the wires and mount the base by using
4pcs of anchor screws into the wall. 3. Using 4pcs of screws to mount PCB case and
the base. 4. Connect PCB Case and Front cover then install
the bottom security screw. Finish installation.
1. Download Easiprox App (for model Easiprox+ Series and DG Series)
Easiprox
Download Easiprox App to set up. Scan QR Code on the left or download the App from Apple Store or Google Play depending on what kind of smartphone you use. Smartphone compatibilityj Android 5.0 and up, iOS 9.0 and up
2. App Main Page Introducon Login
AdministratorjEnter Admin ID and Passcode to login. Admin IDjADMIN Default Admin Passcodej12345 (Passcodej4~8 digits)
UserjEnter User ID and User Passcode to login. User ID and User Passcode are given by the Administrator.
[Note]
1.) Administrator ID “ADMIN” can not be changed. Please change Admin’s
default passcode “12345” right after you login as the Admin.
Go to setting page, press Admin Passcode to Edit Admin Passcode. 2.) Login Success / Login Failure indicaons will be shown as followingj
Login SuccessjYou Have Successfully Logged In. You May Now Unlock A Door.
Login FailurejLogin Failed. Please Verify Your Login Information Or Contact Your Administrator.
3
So[ware App Operaons
Device name
Choose which device you want to unlock by pulling down the Device
name listing.
Device distance
The distance between you and the Bluetooth Keypad/Reader.
Sengs
Tap “Settings” to view or change setting functions.
LOCKED / UNLOCKED
LOCKEDjDoor lock status is Locked. (Default).
UNLOCKEDjPress unlock the door.
button or the door icon to
Auto
Press “Auto” to enable Auto unlock function to access.
Make sure to disable “Auto” before pressing
to enter Settings page.
Auto Proximity Range
Adjust Auto Proximity Range in Settings page. The range is between 0 to maximum 20 and it may have different results under different circumstances.
3. Administrator ” Sengs” Page Introducon
Tap “Settings” to view or change setting functions in Users “Setttings” Page.
Usersj(See Figure 1 below)
a. Add / Delete / Edit user information. b. If there are many users, you can search User ID (Enter an User ID to search user).
(See Figure 2 below) c. ID (Up to 16 characters) d. Passcode (4~8 digits) e. Card / Fob numberjEnter or Edit 10 numbers from a card or key fob. f. Phone AccessjEnable / Disable phone access for a user. (See Figure 3 below) h. Keypad AccessjEnable / Disable keypad access for a user. (See Figure 3 below) g. Card / Fob AccessjEnable / Disable Card and Key Fob access for a user.
(See Figure 3 below)
b.
Figure 1
Figure 2
Figure 3
4
So[ware App Operaons
i. Access Typej(4 options) (See Figure 4 below) (A) PermanentjPermanent access is given by default. (B) TemporaryjSet specific access time period for guests and visitors. (C) Number of TimesjTo set number of access granted to user.
(Please enter a number between 0 to 255) (D) ScheduledjTo assign repeatedly access on specific days and hours for a certain period of
time. This setting is useful for house cleaners or constructors who need temporary access on regular basis. (See Figure 4 and 5)
Audit Trailj(See Figure 6 and 7 below)
a. Audit Trail is tracking last 1000 event logs including Tamper Alarm. b. Enter an user ID to search events for an user. c. Tap to export all events to excel file. d. Tap to refresh all events.
Backup Dataj(See Figure 8 below)
Backup Data is to backup Users, Admin Passcode, Admin Card/Fob, Door Sensor, Lock Action, Tamper Alarm and Door Re-lock Time to Administrator’s phone and can be restored except Device Name, Tamper Sensor Level, Auto Proximity Range, About Us and Audit Trail logs. Step 1jPress “Backup Data”, the App will showj Backup all data now? Step 2jPress Confirm, the App will showj Backup Status Backup Complete!
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Restore Backup (See Figure 8)
Restore the last backup data by Admin’s phone to a new Access Control Keypad / Reader. Step 1jPress “Restore Backup”, the App will showj Restore all data now? Step 2jPress Confirm, the App will showj Restore Status Restore Complete!
Administrator ” Sengs” Page Introducon Connuedj (See the Figure next page)
· Device NamejEdit Device Name (Up to 16 characters) · Admin PasscodejEdit Admin Passcode 4~8 digits) · Admin Card/FobjEdit Admin Card/Fob number (10 numbers on your card or key fob) · Door Sensor j
Enable Door Sensor when you connect to a closed-circuit magnetic sensor or a monitored door lock that has door sensor (or lock sensor) outputs to monitor the open or closed state of a door. · Lock Aconj 3 options) Choose Door Re-lock Time, Door Always Unlocked, and Door Always Locked.
5
So[ware App Operaons
· Tamper Alarmj If the device is vandalized, the tamper alarm will beep immediately and won’t go off until it’s switched off by Administrator.
· Tamper Sensor Levelj Level 1 (High Sensitivity) Level 2 (Mid Sensitivity) Level 3 (Low Sensitivity)
· Door Re-lock Timej 6 seconds by default. Edit the Door Re-lock Time interval between 1 to 1800 seconds.
· Auto Proximity Rangej Adjust Auto Proximity Range here. The range is between 0 to maximum 20 and it may have different results under different circumstances.
· Device Timej Make sure the Device Time is precisely synced with your current time zone to have correct and precise access data and information.
· About usjView Device Models, App version, Website and E-Mail information. · Firmware versionjSee Firmware version of your Bluetooth Access Control Keypads/Readers.
4. User’s ” Sengs” Page Introducon
Tap “Settings” to view or change setting functions in User’s “Settings” Page. (See Figure 9 below) · Device NamejUser can only view the Device Name. (See Figure 10 below) · Auto Proximity RangejUser can adjust Auto proximity range between 0 to maximum 20 to access.
May have different results under different circumstances. (See Figure 11 below) · About UsjView Device models, App version, Website information.
Figure 9
User’s Settings Page Figure 10
Figure 11
P-MU-Easiprox+_2022.10.21
6