48V LifePo4 Battery Pack
Product Information
Layout of Front Panel
| NO. | Name |
|---|---|
| 1 | Positive Terminal |
| 2 | SOC |
| 3 | ALM |
| 4 | RUN |
| 5 | ADD |
| 6 | Negative Terminal |
| 7 | Power Switch |
| 8 | Reset |
| 9 | RS485*2/CAN*2 |
| 10 | LCD Screen |
Battery Specifications
| Nominal Parameters | LFP48100P | LFP48150P |
|---|---|---|
| Model No | LFP48100P | LFP48150P |
| Voltage | 51.2 V | 51.2 V |
| Capacity | 100Ah | 150Ah |
| Energy | 5KWh | 7KWh |
| Dimensions (L * W * H mm) | 480*440*160 | 480*440*200 |
| Weight (KG) | Approx 48 | Approx 60 |
| Built-in BMS | 16S 100A | 16S 200A |
| Electrical Parameters | ||
| Operation Voltage | 51.2 VDC | 51.2 VDC |
| Max. Charging Voltage | 58.4 VDC | 58.4 VDC |
| Cut-off Discharge Voltage | 43.2 VDC | 43.2 VDC |
| Max. Continous Charging and Discharging Current | 100A | 150A |
| Peak Discharge Current | 150A (5s) | 250A (5s) |
| Basic Parameters | ||
| Cycles | 6000 times | |
| Communication Method | RS485/CAN | |
| Display Method and Language | LCD, English | |
| Operating Temperature Range | -20~70 | |
| Operating Humidity Range | 10%~85% | |
| Additional Model | LFP48200P | |
| Voltage | 51.2 V | |
| Capacity | 200Ah | |
| Energy | 10KWh | |
| Dimensions (L * W * H mm) | 480*440*255 | |
| Weight (KG) | Approx 85 | |
| Built-in BMS | 16S 200A | |
| Electrical Parameters | ||
| Operation Voltage | 51.2 VDC | |
| Max. Charging Voltage | 58.4 VDC | |
| Cut-off Discharge Voltage | 43.2 VDC | |
| Max. Continous Charging and Discharging Current | 200A | |
| Peak Discharge Current | 250A (5s) |
Working Mode
3.1. Basic Mode
LED Indicator Description
Four green capacity indicators, one red alarm indicator, one
green operation indicator
SOC Capacity Indicator
| Status | L1 | L2 | L3 | L4 |
|---|---|---|---|---|
| 0-25% | OFF | OFF | OFF | Flash 2 |
| 25-50% | OFF | OFF | ON | Flash 2 |
| 50-75% | OFF | ON | ON | Flash 2 |
| 75-100% | ON | ON | ON | Flash 2 |
Status Indicator
| Status | RUN | ALM |
|---|---|---|
| Standby | OFF | OFF |
| Charge | ON | OFF |
| Discharge | OFF | ON |
| Warning/Normal | ON | OFF |
Flash Instruction of LED Indicators
| Flash 1 | Flash 2 | Flash 3 |
|---|---|---|
| ON 0.25 S | ON 0.5 S | ON 0.5 S |
| OFF 3.75 S | OFF 0.5 S | OFF 1.5 S |
Communication
With RS485 and CAN interface, which supports communicating with
multiple machines in parallel and with the upper computer. RS485
baud rate is 19200, CAN baud rate is 500K.
RS485 INTERFACE
8P8C RJ45 Pins Assignment (RS485)
| Pins | Definition |
|---|
V20220512
48V LiFePO4 BATTERY PACK
USER MANUAL
CONTENT
V20220512
1. Layout of Front Panel ——————————————————————— 1 2. Battery Specifications ——————————————————————— 2 3. Working Mode ————————————————————————— 3
3.1. Basic Mode ————————————————————————-3 3.2. Description of Buzzer —————————————————————-3 3.3. Description of Reset Button ———————————————————- 3 3.4. Dormancy and Activation ———————————————————— 3 4. LED Indicator Description ——————————————————————4 4.1. LED Indicator Description ———————————————————— 4 4.2. SOC Capacity Indicator ————————————————————– 4 4.3. Status Indicator ———————————————————————4 4.4. Flash Instruction of LED Indicators —————————————————- 4 5. Communication ————————————————————————– 5 6. Assignment of ID Addresses ————————————————————— 6 7. LCD Display Introduction —————————————————————— 7 7.1. Power-on screen ——————————————————————–7 7.2. Press “MENU” to enter the main menu ———————————————— 8 7.3. Dormancy and Activation Function ————————————————– 12 8. Upper Computer Software Introduction —————————————————- 13 9. List of Accessories ———————————————————————– 17
1. Layout of Front Panel
V20220512
NO.
Name
1
Positive Terminal
2
SOC
3
ALM
4
RUN
5
ADD
6
Negative Terminal
7
Power Switch
8
Reset
9
RS485*2/CAN*2
10
LCD Screen
Function Charge & Discharge Indicators For Capacity Indicator For Alarms Indicator For Running Status Dial Code Of Communication Charge & Discharge ON/OFF Switch Activate/Hibernate BMS Communication Interface Display Battery Information
1
V20220512
2. Battery Specifications
Nominal Parameters
Model No
LFP48100P
LFP48150P
Voltage
51.2 V
51.2 V
Capacity
100Ah
150Ah
Energy
5KWh
7KWh
Dimensions (L * W * H mm)
480*440*160
480*440*200
Weight (KG)
Approx 48
Approx 60
Built-in BMS
16S 100A
16S 200A
Electrical Parameters
Operation Voltage
51.2 VDC
51.2 VDC
Max. Charging Voltage
58.4 VDC
58.4 VDC
Cut-off Discharge Voltage
43.2 VDC
43.2 VDC
Max. Continous Charging and Discharging Current 100A
150A
Peak Discharge Current
150A (5s)
250A (5s)
Basic Parameters
Life Time(25°C)
10 years
Communication Method
RS485/CAN
Display Method and Language
LCD, English
Life Cycles (70% DOD, 25°C)
6000 times Cycles
Operating Temperature Range
-20~70
Operating Humidity Range
10%~85%
LFP48200P 51.2 V 200Ah 10KWh 480*440*255 Approx 85 16S 200A
51.2 VDC 58.4 VDC 43.2 VDC 200A 250A (5s)
2
V20220512
3. Working Mode
3.1. Basic Mode
3.1.1. Charging Mode The BMS turns on the charging MOSFET for charging when it detects an external charging voltage of 48V, and the cell voltage and temperature are within the chargeable range. When the charging current reaches the effective charging current, it enters the charging mode. Both charging and discharging MOSFETs are on in charge mode. 3.1.2. Discharging Mode The BMS enters the discharge mode when it detects that the load is connected and the cell voltage and temperature are within the dischargeable range and the discharge current reaches the effective discharge current. 3.1.3. Standby Mode When neither of the above two modes is met, it enters standby mode. 3.1.4. Hibernation Mode The BMS will enter sleep (shutdown) mode after a specific time of standby, or when the battery triggers undervoltage protection, or when the key is executed to shutdown or when the upper computer executes the shutdown command mode. The wake-up conditions of hibernation mode: 1. Make charging to activation; 2. Press the button to power on. 3.2. Description of Buzzer Buzzer function can be enabled or disabled via the upper computer, factory default is disabled. 3.3. Description of Reset Button When the BMS is dormant, press the button for 1S and then release it, the protection board will be activated and the LED will light up from “L4” for 0.5 seconds. When the BMS is active, press the button for 3S and then release it, the board will be dormant and the LED will light up from “RUN” for 0.5 seconds. 3.4. Dormancy and Activation
3.4.1. Dormancy The system will enter low-power mode when any of the following conditions are met. 1. Single cell undervoltage protection or overall undervoltage protection is not released within 30 minutes. 2. Press the button for 3 seconds and then release the button. 3. The minimum individual voltage is lower than the sleep setting voltage (default value 3150mV) and the duration reaches the sleep delay time (default value 1440 minutes), and there is no communication and no charging/discharging in meanwhile. 4. Forced shutdown via the upper computer software. Note: Before entering hibernation, make sure that no external voltage is connected to the P-terminus, otherwise it will not be able to enter the low-power mode. 3.4.2. Activation When the system is in low-power mode and any of the following conditions are met, the system will exit low-power mode and enter normal operation mode. 1. Connect to the charger, the charger output voltage should be greater than or equal to 48V. 2. Press the button for 1S, after releasing the button.
3
V20220512
4. LED Indicator Description
4.1. LED Indicator Description
Four green capacity indicators, one red alarm indicator, one green operation indicator
SOC
ALM
RUN
4.2. SOC Capacity Indicator
Status Capacity Indicator
025% 2550% 5075% 75100% Running Indicator
L1 OFF OFF OFF Flash 2
Charge
L2
L3
OFF
OFF
OFF
Flash 2
Flash 2
ON
ON
ON
ON
L4 Flash 2
ON ON ON
L1 OFF OFF OFF ON
Discharge
L2
L3
OFF
OFF
OFF
ON
ON
ON
ON
ON
Flash 3
L4 ON ON ON ON
4.3. Status Indicator
Status OFF Standby
Charge
Discharge
Warning/Normal
Normal Warning Normal Over Voltage Warning Over Current, Over Voltage and Temperature Warning Over Voltage Protection Over Current Protection Normal Warning Low Voltage Protection Protection of Overcurrent, Short Circuit, Temperature, Reverse Polarity etc
RUN ALM
OFF
OFF
Flash 1 OFF
Flash 1 Flash 2
ON
OFF
ON
OFF
SOC LED
ALL OFF
Mark
ON
Flash 1 ON
Flash 3 Flash 3 Flash 1
Flash 2
OFF OFF OFF Flash 2 Flash 2
ON as battery capacity indicates
OFF
ON
ALL OFF
4.4. Flash Instruction of LED Indicators
Flash 1 Flash 2 Flash 3
ON 0.25 S 0.5 S 0.5 S
OFF 3.75 S 0.5 S 1.5 S
4
V20220512
5. Communication
With RS485 and CAN interface, which supports communicating with multiple machines in parallel and with the upper computer. RS485 baud rate is 19200, CAN baud rate is 500K.
RS485 INTERFACE
8P8C RJ45 Pins Assignment (RS485)
Pins 13
7 26
4 5 8
Definition RS485_B RS485_A
GND CANH CANL
NC
The multi-unit parallel bus connections are shown in the following figure.
Instructions For Compatibility With Inverters
1. Compatible inverter brands list
Victron, Pylontech, Goodwe, Growatt, Voltronic, Deye, LXP, Sofar, GinLong, SMA, ,
Salocor If you can provide the communication protocol (a kind of code) of your inverter, we can customize the BMS to be compatible with your inverter, minimum order quantity for customzed is 50 pcs.
2. If your inverter not on our list above
Without communication protocol, inverter cannot communicate with our battery. You need to make some setting on your inverter, for example, select the user-defined mode and set the corresponding voltage level(according to the inverter user manual), so that they can work together without communication.
More questions about inverter communication, pls contact our customer service.
5
V20220512
6. Assignment of ID Addresses
When performing parallel communication operation of multiple machines, you need to configure the dialing address of each PACK first. When the BMS is configured for stand-alone operation, and the dialing address can be any address; when the BMS is configured for cascade operation mode, the slave dialing address is selected from 1 to 31, and the host dialing address is selected from 32 or 48 according to the inverter brand.
You can enter the address code of the master or slave battery in the system parameters of the upper computer to detect and communicate.
1
2
Code
3
4
5
6
ADD
PACK NO.
Remarks
ON
OFF
OFF
OFF
OFF
OFF
1
PACK 1
OFF
ON
OFF
OFF
OFF
OFF
2
PACK 2
ON
ON
OFF
OFF
OFF
OFF
3
PACK 3
OFF
OFF
ON
OFF
OFF
OFF
4
PACK 4
ON
OFF
ON
OFF
OFF
OFF
5
PACK 5
OFF
ON
ON
OFF
OFF
OFF
6
PACK 6
ON
ON
ON
OFF
OFF
OFF
7
PACK 7
OFF
OFF
OFF
ON
OFF
OFF
8
PACK 8
ON
OFF
OFF
ON
OFF
OFF
9
PACK 9
OFF
ON
OFF
ON
OFF
OFF
10
PACK 10
ON
ON
OFF
ON
OFF
OFF
11
PACK 11
OFF
OFF
ON
ON
OFF
OFF
12
PACK 12
ON
OFF
ON
ON
OFF
OFF
13
PACK 13
OFF
ON
ON
ON
OFF
OFF
14
PACK 14
ON
ON
ON
ON
OFF
OFF
15
PACK 15
OFF
OFF
OFF
OFF
ON
OFF
16
PACK 16
Slave Pack
ON
OFF
OFF
OFF
ON
OFF
17
PACK 17
OFF
ON
OFF
OFF
ON
OFF
18
PACK 18
ON
ON
OFF
OFF
ON
OFF
19
PACK 19
OFF
OFF
ON
OFF
ON
OFF
20
PACK 20
ON
OFF
ON
OFF
ON
OFF
21
PACK 21
OFF
ON
ON
OFF
ON
OFF
22
PACK 22
ON
ON
ON
OFF
ON
OFF
23
PACK 23
OFF
OFF
OFF
ON
ON
OFF
24
PACK 24
ON
OFF
OFF
ON
ON
OFF
25
PACK 25
OFF
ON
OFF
ON
ON
OFF
26
PACK 26
ON
ON
OFF
ON
ON
OFF
27
PACK 27
OFF
OFF
ON
ON
ON
OFF
28
PACK 28
ON
OFF
ON
ON
ON
OFF
29
PACK 29
OFF
ON
ON
ON
ON
OFF
30
PACK 30
ON
ON
ON
ON
ON
OFF
31
PACK 31
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
Master Pack: if your inverter is from other brands except 32
Victron, SMA and Growatt, the ADD of master pack is 32 PACK 32
Master Pack: if your inverter is from Victron, SMA or 48
Growatt, the ADD of master pack is 48
6
V20220512
7. LCD Display Introduction
7.1. Power-on screen
Button description:
MMMMMENU
ENTER ESC
MENUEnter the management system. ENTEREnter to the sub-menu. Move the cursor down or to next page. ESCReturn to the previous menu.
System Date Charging/Discharging Current Total Voltage Remaining Capacity Max. Voltage of Single Unit
SOH Environmental Temperature Max. Temperature of Battery Cell SOC Min. Voltage of Single Unit
Battery protection status Over Voltage: OV Low Voltage: LV Over Temp: OT Low Temp: LT Over Current: OC Short Circuit: SC
Note: When there is protection situation of the battery, there will show the corresponding protection status, otherwise, the protection status will not be showed.
7
7.2. Press “MENU” to enter the main menu (Note: “” means there is a sub-menu, press “ENTER” to enter the sub-menu)
BMS Parameter Battery Status GYRO Status Version Number
V20220512
7.2.1. Move the cursor to “BMS Parameter” and press “Enter” to enter. Voltage Current Cell Temp Cell Volt
0.00V 0.0A
Move the cursor to “Cell Temp” and press “Enter” to check the battery temperature information, then press ” ” to turn the page.
Temp 01
xx
Temp 02
xx
Temp 03
xx
Temp 04
xx
MOS Temp
xx
Env Temp
xx
8
V20220512
Move the cursor to “Cell Volt” and press “Enter” to check the battery voltage information, then press “” to turn the page.
Cell 01
xxxxmV
Cell 02
xxxxmV
Cell 03
xxxxmV
Cell 04
xxxxmV
Cell 05
xxxxmV
Cell 06
xxxxmV
Cell 07
xxxxmV
Cell 08
xxxxmV
Cell 09
xxxxmV
Cell 10
xxxxmV
Cell 11
xxxxmV
Cell 12
xxxxmV
Cell 13
xxxxmV
Cell 14
xxxxmV
Cell 15
xxxxmV
Cell 16
xxxxmV
SOC
xx%
Nominal Capacity
0.0AH
Remain Capacity
0.0AH
BMS Cycles
0
9
V20220512
7.2.2. Move the cursor to “Battery Status” and press “Enter” to check the battery status information, then press “” to turn the page.
Status
IDLE/DISCHG/CHARGE/FULL
Alarm Status
Protect Status
Failure Alarm
Move the cursor to “Alarm Status” and press “Enter” to check the battery alarm information, then press “” to turn the page.
Over Volt
YES/NO
Low Volt
YES/NO
Over Temp
YES/NO
Low Temp
YES/NO
Low SOC
YES/NO
Diff Volt
YES/NO
Over Curr
YES/NO
Reverse
YES/NO
Move the cursor to “Protect Status” and press “Enter” to check the battery protection information, then press “” to turn the page.
Over Volt
YES/NO
Low Volt
YES/NO
Over Temp
YES/NO
Low Temp
YES/NO
Over Curr
YES/NO
Short Curr
YES/NO
10
V20220512
Move the cursor to “Failure Alarm” and press “Enter” to check the battery fault information, then press “” to turn the page.
Sample Line
N/Y
Charge MOS
N/Y
Dis CHG MOS
N/Y
Sample Chip
N/Y
SC Times
0
Over Temp CNT
0
Over Cur CNT
0
OVER Chg CNT
0
Over Dchg CNT
0
7.2.3. Move the cursor to “GYRO Status” and press Enter to check the gyroscope information, then press “” to turn the page. (Note: This gyroscope is optional)
Set X axis:
Place Option:
7.2.4. Move the cursor to “Version number” and press Enter to check the version information, then press “” to turn the page.
BMS Version
LCD Version
11
Move the cursor to “BMS Version” and press “Enter” to check the BMS version information. BMS SW Version
V20220512
BMS HW Version
Move the cursor to “LCD Version” and press “Enter” to check the LCD version information. LCD SW Version
LCD HW Version
7.3. Dormancy and Activation Function
After 1 minute of no button operation in normal running, the display screen will be off (only the backlight is off). Pressing any button while the screen is off will allow the screen light and operate normally.
12
8. Upper Computer Software Introduction
V20220512
Enable the monitoring software, select the communication interface of the corresponding device, select the corresponding baud rate, and finally click “Open Serial Interface” to communicate with BMS and get the basic parameters.
You can switch the version in Chinese or English in help center
After the BMS communicates with the upper computer, you can monitor the basic parameters and status of the battery in real time. These information include battery voltage, current, SOC, SOH, cycle count, battery temperature, alarm status, protection status, etc.
13
V20220512
You can view the real-time data storage of the BMS and export as excel tables.
When monitoring multiple packs, you need to set the start and end address of packs manually, you can check and comparethe data of each pack. And you can also export as excel table.
Basic parameters 1. Click “Read All” when enter for the first time. This section includes reading basic parameter information, restoring default parameters, writing individual parameters, writing all parameters, importing parameters and exporting parameters (it is not recommended to manually modified default parameters).
14
V20220512
Basic parameters 2. Click “Read All” when enter for the first time. This section includes heating settings, other BMS parameter information, etc. (it is not recommended to manually modified default parameters).
System parameter setting. Click “Read All” when enter for the first time. You can monitor the BMS parameters configuration, sleep settings and BMS information in real-time(it is not recommended to manually modified default parameters).
Data calibration: Here is calibration content of BMS data (all has calibrated by factory, not recommended for private calibration).
Plug-in modules: Here will contains information about some additional functional modules.
15
V20220512
Normal remote control: Here includes the control of charging and discharging MOS, heating and other states (please consult the manufacturer for operation). Online upgrade: software online upgrade function of BMS (please consult the manufacturer for operation). System Parameters 1. Here includes some basic parameter information and dormancy settings.
Click “Read Data” to get real-time history data and export data, and view basic data information of battery packs.
16
9. List of Accessories
NO.
ITEM
PICTURE
QTY
V20220512
Remarks
1
Battery Pack
1
2 Parallel Power Cable
Parallel 3 Communication Cable
For 48V 100AH: 6 gauge cable 0.3M + SC25-8 connector 2 For 48V 150AH/200AH: 4 gauge cable 0.4M + SC35-8 connector
1 RJ45 cable 0.5M
4
Upper computer Connecting Cable
1 RJ45 to USB cable 2M
5
Screws
4 M8
17