4000W High Frequency Inverter
High Frequency Inverter
Instructions for Use
Please read this manual carefully before using the product.
Thank you for choosing the vehicle inverter provided by us. We hope
our products can bring you the most satisfied service.
1. Product Description
This high frequency inverter has adapted SPWM technology, making
it highly efficient and reliable. The product has passed
ISO9001:2000. However, improper operation or misuse may still cause
injury or loss. Therefore, instructions and information provided in
this manual must be followed at all times.
2. Technical Parameters
| Model | Input Output | Output Voltage | Loss When No Load | Output Wave | Surge Power | Output Frequency Efficiency |
|---|---|---|---|---|---|---|
| 1000W | DC12V/24V/48V/60V (not automatically) | – | 1A | Pure Sine Wave – Modified Wave | 2000W | 85% |
| 1500W | – | 1.2A | – | – | 3000W | – |
| 2000W-2500W | – | 1.8A | – | – | 4000W-5000W | – |
| 3000W | – | – | – | – | 6000W | – |
| 4000W | – | – | – | – | 8000W | – |
| 5000W-6000W | – | – | – | – | 10KW-12KW | – |
Note: Keep the power supply around the
ventilation dry, within 1 meter must not have flammable items,
strictly preventing the cause of fire.
3. Protective Functions
Overload protection: when overloading 125%, the inverter will
send an alarm, and stop working after 20 seconds.
4. Installation Precautions
The inverters are designed, manufactured and tested as per
safety standards. However, as an electrical and electric product,
it must be installed, operated and maintained strictly according to
the related safety instructions as follows:
5. Trouble Shooting
If you encounter any issues with the inverter, please refer to
the troubleshooting section of the manual for assistance.
6. Warranty
The company provides a free warranty period of one year. Please
note that the dealer is in contact with the warranty and repair
business. The failure range of this insurance clause does not
include damage caused by external factors: incorrect installation,
misuse or improper operation, unauthorized private maintenance,
damage during transportation, etc.
7. Random Accessories
Products are carefully tested and inspected prior to shipment,
but it is still possible to receive damage in transit, please
carefully check the equipment before installation. If there is any
damage, contact the distributor in time. The following accessories
are included:
- Portable Inverter power supply – 1
- Power Cable Pair – 2
- A copy of the product instruction manual – 1
- A copy of the car spare fuse – 1
- Desiccant Bag – 1
- External screen set (including cable) – 1
8. Panel Diagram
The panel diagram shows the various components and their
functions:
- Product Input Voltage
- Frequency
- Product Output Voltage
- Battery power
- Product power
- Product Waveform
- Mains connection (with charging function)
- Working status
- High voltage/low voltage protection
9. Instructions for External Wired Remote Control
Equipment
The inverter can be remotely controlled to turn on and off.
Digital display battery voltage value. The equipment adopts a wall
switch design scheme, which can be installed in RVs and homes
according to user needs. Comes with convenient stickers, which can
be pasted at will.
- Battery power
- Fault indicator
- Input voltage
- Work indicator
- Inverter switch key
10. Remote Control Connection Diagram
The connection diagram shows how to connect the remote control
to the inverter.
1
1. The load (appliances) power aka the output of the inverter shall not be greater than the rated power, which could lead the inverter out of work. 2. Please ensure the input voltage of the inverter of the battery shall comply with the rated voltage, the inverter would be damaged, if the input voltage would be greater than 1.6 times the rated voltage. 3. When connected with an inductive or capacitive load, please reverse the allowance 3-5 times of load power. (aka 4-6 x Appliance power) 4. Red to the positive pole, Black to the negative pole, please connect it properly. Reversely connection would melt the fuse, it could work normally after replacing the fuse and connecting properly. 5. Forbidden to plug the inverter in mains power.
2
High frequency inverter
Instructions for use
Please read this manual carefully before using products. Thank you for choosing the vehicle inverter provided by us. We hope our products can bring you the most satisfied service.
1 Product Description
This high frequency inverter has adapted SPWM technology, and it’s highly efficient and reliable. Product has passed lS09001:2000. However, improper operation or misuse may still cause injury or loss, instruction and information provided in this manual must be followed all the time.
2 Technical Parameters
Model
1000W
1500W
2000W-2500 W
3000W
4000W
5000W-6000 W
Input output
DC12V/24V/48V/60V(not automatically)
Output voltage
Loss when no load
AC220V±10% -120V±10%not automatically
1A
1.2A
1.8A
Output wave
Pure sine wave – Modified wave
Surge Power
Output frequency Efficiency
2000 W
3000 W
4000W-500 0W
6000 W
8000 W
50Hz±0.5Hz or 60Hz±0.5Hz
85%
10KW-12K W
Over voltage
16V – 30V – 60V – 75V
Low voltage shutting
9.5V – 20V – 40V – 50V
Over temperature
shutting
80
Ambient temperature
-10 – +45
Note: Keep the power supply around the ventilation dry, within 1 meter must not
have flammable items, strictly preventing the cause of fire.
3Protective Functions
Overload protection: when overloading 125%, the inverter will send an alarm, and stop working after 20 seconds.
3
1. Loads are reduced to the accepted level, the inverter will resume working. 2. Short circuit protection: inverter is with short circuit protection. 3. Over-temperature protection: when the inside temperature of the inverter reaches 80, the RED indication light will be on. The inverter will stop working, once the temperature drops to accepted level, the inverter will automatically resume working. 4. Low voltage protection: when the battery voltage is below the setting level, the inverter will send an alarm by beeping. When the battery voltage keeps dropping to its shutting level, the inverter will beep, and the RED LED will light, the inverter will stop working, when the battery voltage is increased to its restart level, the inverter will automatically resume working. 5. Over voltage protection: when the input voltage is higher than the setting level, the inverter will stop working, when the input voltage is normal, it will automatically resume working. 6. Reverse connection protection: once there is a reverse connection, the inverter fuse will be burnt. ln this case, please switch off the inverter, disconnect the power source, and change the fuse. REVERSE CONNECT IS STRICTLY PROHIBITED. 7. LCD display: Inverter display as LCD LCD screen, display a variety of states, the following drawings detailed introduction.
4 Installation
1. The function of inverter is to convert the DC 12v/24v/48v/60v voltage into AC 110v/220V, before connection, please make sure the inverter is switched off. 2. When connecting the inverter to the battery, make sure that the battery voltage is consistent with the inverter reference voltage! ! ! 3. Connect the Red cable of the inverter to the Positive pole of battery, Connect the Black cable of the inverter to the Negative pole of battery. Do not connect the cable reversely, otherwise, the inverter fuse will be burnt. 4. Turn on the inverter power switch, at which point the green (blue) indicator light is on, indicating that the inverter is working properly. 5. Please connect the loads to the AC output of the inverter, please do not overload. in the case of overloading, the inverter will send an alarm and stop working. To restart the inverter, please firstly switch off the inverter for 5 seconds, reduce the load, and switch it on again.
5) Precautions
The inverters are designed, manufactured and tested as per safety standards. However, as an electrical and electric product, it must be installed, operated and maintained strictly according to the related safety instructions as follows:
4
1. Reverse connection between the inverter and battery is strictly prohibited, it will burn the fuse of the inverter. 2. Please double check if the voltage of the battery matches the inverter input DC voltage, a mismatch connection between the inverter and battery can cause serious damage. 3. Double check if the connections are correct, make sure the connections are tight and firm. 4. Do not extend the inverter power cable. 5. When the inverter is not in use, please switch it off and disconnect inverter from the system. 6. Avoid contacting of any foreign objects or fluid. Do not touch the inverter with a wet hand. Keep the product away from children. Avoid using it in damp, dusty, high-temperature area. Do not use this product in1lammable and combustible areas. 7. Install the product in a well-ventilated place, avoid using this product on or nearby hot objects such as electrical heaters, etc. Do not cover the inverter, avoid direct sunshine, moisture, and water. 8. This inverter can not be parallel connected. 9. It’s strictly prohibited to connect this product to the city grid. 10. Do not try to repair the inverter, Once the inverter is opened, warranty is void.
6) Trouble Shooting
When there is no output, please check the follows: 1. Excessive use of electrical appliances, too heavy load. Solution: Reduce electrical appliances, the use of electrical total power should be less than the inverter rated power. 2. Overheat protection. WORKAROUND: Reduce load cooling and restart after 15 minutes. (Summer temperature is high or the heat dissipation conditions are poor, should be appropriately reduced the use of the total power of electrical appliances.) 3. It must replace the fuse with the same capacity after fusing 4. Loose connection of the cable: make sure the cable is firmly and tightly connected. 5. Low voltage of battery; please charge the battery. 6. Battery exhausted: Please change battery, battery can be exhausted over the years.
7) Warranty
1. The company provides a free warranty period of one year. Please note that the dealer is in contact with the warranty and repair business.
5
2. The failure range of this insurance clause does not include damage caused by external factors: incorrect installation, misuse or improper operation, unauthorized private maintenance, damage during transportation, etc.
8) Random Accessories
Products are carefully tested and inspected prior to shipment, but it is still possible to receive damage in transit, please carefully check the equipment before installation. If there is any damage, contact the distributor in time. 1. Portable Inverter power supply One 2. Power Cable Pair 3. A copy of the product instruction manual 4. A copy of the car spare fuse 5. Desiccant Bag 6. External screen set (including cable one)
9) Panel diagram
Product Input Voltage Frequency Product Output Voltage Battery power Product power Product Waveform Mains connection (with charging function) Working status High voltage/low voltage protection
6
10Instructions for external wired remote control equipment
Equipment introduction: The inverter can be remotely controlled to turn on and off. Digital display battery voltage value. The equipment adopts a wall switch design scheme, which can be installed in RVs and homes according to user needs. Comes with convenient stickers, which can be pasted at will.
Battery power Fault indicator Input voltage Work indicator Inverter switch key
Remote Control Connection Diagram
7
Backlight On/Of Lead-acid / Lithium Inverter switch key
Remote Control Connection Diagram
8
Packing list
Inverter
1
Input wiring
2
Remote control
1
Remote control cable
1
Fuse
1
Instructions
1
Inverter basic fault and troubleshooting method
fault
Fault embodiment
Exclusions
The battery is low
The battery voltage is high
Start by making an alarm sound (judge the alarm sound as one, BI-BI-BI… ),
the LED red light flashes, The voltage continues to decrease and
the machine shuts down.
Alarm sound first (judge alarm sound is two, BIBI – BIBI – BIBI…) THE LED
red light flashes, The voltage continues to rise and the
machine shuts down.
The battery is fully charged
The battery is fully charged or replaced in line with the nominal voltage of the inverter
Too much load
The temperature is too high
The output is shorted The battery is turned
back
First issue an alarm sound (judge the alarm sound as a continuous alarm, BIBIBIBIBIBI… ), the LED flashes red
and the machine shuts down.
Alarm sound first (judge alarm sound is three, BIBIBI – BIBIBI – BIBIBI… ), the LED flashes red, the temperature
continues to rise, and the machine shuts down.
Alarm sound without damaging the circuit (judge alarm sound as
continuous alarm, BIBIBIBIBI…)
The built-in fuse is blown and the machine is powered on and unresponsive.
Reduce the load
Subtract the load and wait for the inverter to
cool down
Just disconnect the short circuit
Replace the new fuse
9