AS840 Ultrasonic Thickness Gauge
Product Information
Ultrasonic Thickness Gauge
The Ultrasonic Thickness Gauge is available in three models:
AS840, AS850, and AS860. It is designed to measure the thickness of
various materials, with a measuring range of 1.2mm to 225mm
(Steel). The gauge operates at a frequency of 5MHz and has an
accuracy resolution of 1000~9999m/s. It features sound velocity
measuring and storage capabilities, with the ability to store up to
12 groups of data. The gauge also includes a backlight display,
auto zero calibration, auto linear compensation, coupling
indicator, and battery indication. It can be powered by a 9V
battery and has a net weight of 200g.
Differential Pressure Meter Film / Coating Thickness Gauge
The Differential Pressure Meter Film / Coating Thickness Gauge
is available in two models: AS510 and AS930. It is designed to
measure differential pressure and film/coating thickness. The AS510
model has a measuring range of hPa, mbar, mmH2O, mmHg, inH2O, inHG,
m/s, fpm, while the AS930 model has a measuring range of 0~1800m.
Both models operate on 3*1.5V AAA batteries and feature a backlight
display, alarm buzzer, zero/two-point/basic calibration,
single/continuous/standard deviation measurement, data storage and
recall, data analysis, and metric/imperial switchable units.
Film / Coating Thickness Gauge
The Film / Coating Thickness Gauge is available in two models:
AS931 and AS931. Both models have a measuring range of 0~1800m and
operate on a 9V battery. They feature a measuring principle of
magnetic induction, with an accuracy resolution of 0.1m/1m. The
gauges have a minimum curvature radius of Convex=1.5mm and
Concave=9mm, a base sample diameter of 7mm, and a base substrate
thickness of 0.5mm. They also include a backlight display, alarm
buzzer, zero/two-point/basic calibration,
single/continuous/standard deviation measurement, data storage and
recall, data analysis, max & min measuring, AVG & DFR
measuring, and metric/imperial switchable units.
Product Usage Instructions
Ultrasonic Thickness Gauge
- Ensure the gauge is powered by inserting a 9V battery.
- Select the desired model: AS840, AS850, or AS860.
- Place the transducer on the material surface to be
measured. - Read the thickness measurement displayed on the gauge.
- If necessary, store the measurement data by pressing the
appropriate storage button. - Perform sound velocity measurements and storage as needed.
- Use the backlight display for better visibility in low light
conditions. - Perform auto zero calibration and auto linear compensation when
required. - Monitor the coupling indicator to ensure proper contact between
the transducer and material surface. - Check the battery indication to ensure sufficient power for
accurate measurements. - Choose between auto or manual power off options for
convenience. - If needed, set up max/min thickness alarms for specific
measurement requirements. - Refer to the user manual for specific instructions on using the
gauge with different materials and switching between metric and
imperial units.
Differential Pressure Meter Film / Coating Thickness Gauge
- Insert 3*1.5V AAA batteries to power the gauge.
- Select the desired model: AS510 or AS930.
- Place the gauge in the desired measurement location.
- Read the differential pressure or film/coating thickness
measurement displayed on the gauge. - Use the backlight display for better visibility in low light
conditions. - Be aware of alarm buzzers indicating specific conditions or
thresholds. - Perform zero/two-point/basic calibration as required for
accurate measurements. - Select the appropriate measurement mode: single, continuous, or
standard deviation. - Store and recall measurement data as needed, and perform data
analysis if required. - Refer to the user manual for specific instructions on using the
gauge with different units and power management settings.
Film / Coating Thickness Gauge
- Insert a 9V battery to power the gauge.
- Select the desired model: AS931 or AS931.
- Place the gauge in the desired measurement location.
- Read the film/coating thickness measurement displayed on the
gauge. - Use the backlight display for better visibility in low light
conditions. - Be aware of alarm buzzers indicating specific conditions or
thresholds. - Perform zero/two-point/basic calibration as required for
accurate measurements. - Select the appropriate measurement mode: single, continuous, or
standard deviation. - Store and recall measurement data as needed, and perform data
analysis if required. - Switch between metric and imperial units based on the
measurement requirements. - Monitor the battery indication to ensure sufficient power for
accurate measurements. - Enable auto power off for power-saving purposes.
- Refer to the user manual for specific instructions on using the
gauge with different materials and measurement scenarios.
Ultrasonic Thickness Gauge
SPECIFICATIONS
AS840
AS850
Transducer Measuring Range
10mm 5MHz 1.2~225mm(Steel)
10mm 5MHz / 2.5MHz 1.2~225mm(Steel)
Accuracy Resolution Sound Velocity
±(1%H±0.1mm) 0.1mm
1000~9999m/s
±(1%H±0.1mm) 0.1mm
1000~9999m/s
Operating Frequency
5MHz
5MHz
Operation Condition Minimum Limit For Tube Measuring
0°C~40°C
0°C~40°C 20*3mm(Steel)
Thickness Data Storage
10 groups
10 groups
Sound Velocity Measuring & Storage
Backlight Display Auto Zero Calibration Auto linear compensation Coupling Indicator Battery Indication
12 groups
12 groups
Auto/Manual Power Off
Max / Min Thickness Alarm Setup
—
—
12 Sound Velocities For
—
—
Different Material
Metric / Imperial Switchable
—
—
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power Product Net Weight Product Size Packing Standard Quantity / Carton
Standard Carton Size Standard Carton Gross Weight
9V battery 200g
150 x 80.5 x 34mm Gift box 24
47 x 38 x 55cm 19.5kg
9V battery 210g
150 x 80.5 x 34mm Gift box 10
39x 32 x 44cm 11.0kg
AS860
6mm 5MHz / 10mm 5MHz 1.2~225mm(Steel) ±(1%H±0.1mm) 0.1mm 1000~9999m/s 5MHz 0°C~40°C
12 groups 12 groups
—
9V battery 240g
150 x 80.5 x 34mm Gift box 10
39x 32 x 44cm 11.0kg
Differential Pressure Meter Film / Coating Thickness Gauge
SPECIFICATIONS
AS510
Measuring Range
0~100hPa 0~45.15 inH²O
Accuracy
±0.03 hPa(0~0.30hPa)
±0.05 hPa(0.31~1.0hPa) ±(1.5%+0.1hPa) remaining ±0.01 inH²O(0.00~0.12inH²O) ±0.02 inH²O(0.13~0.40inH²O) ±(1.5%+0.4inH²O) remaining
Resolution
Measuring speed
0.01hPa / 0.01inH²O 0.5 sec
Units
hPa, mbar, mmH2O, mmHg, inH2O, inHG, m/s, fpm
Operation Condition
0~50°C / 32~122°F
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power Product Net Weight Product Size Packing Standard
Quantity / Carton
Standard Carton
Size
3*1.5V AAA batteries 71.5g
124.8 x 49.8 x 25.6mm Gift box 40
52.5 x 40 x 49cm
Standard Carton Gross Weight
19.01kg
SPECIFICATIONS AS930
AS931
Measuring Range Measuring Principle Accuracy Resolution Minimum Curvature Radius
Base Sample Diameter
Base Substrate Thickness
Backlight Display Alarm Buzzer Zero / Two Point / Basic Calibration Single / Continuous / Standard
Deviation Measurement Data Storage & Recall Data Analysis Max & Min Measuring AVG & DFR Measuring Data Storage Metric / Imperial Switchable
Battery Indication Auto Power Off Operation Condition
0~1800m
Magnetic Induction
±(3%H±1m)
0.1m / 1m
Convex=1.5mm Concave=9mm
7mm
0.5mm
15 groups
15 groups
0°C~40°C (without strong magnetic)
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power Product Net Weight Product Size Packing Standard Quantity / Carton
Standard Carton Size Standard Carton Gross Weight
9V battery 147g
183 x 67 x 30mm Gift box 10
39 x32 x 44cm 9.35kg
9V battery 155g
159 x 66 x 31mm Gift box 10
39 x 32 x 44cm 9.8kg
www.neonics.co.th
Tel: 02-077-7602 061-8268939 E-mail: [email protected] [email protected]
Ultrasonic Thickness
Gauge AS850
1.2~225mm
Ultrasonic Thickness
Gauge AS860
1.2~225mm
Ultrasonic Thickness
Gauge AS840
1.2~225mm
Differential Pressure
Meter AS510
0~100hPa 0~40.15inH²O
Film / Coating Thickness Gauge
AS930
0~1800m
Film / Coating Thickness Gauge AS931
0~1800m
6
Ultrasonic Thickness Gauge
SPECIFICATIONS
Transducer Measuring Range Accuracy Resolution Sound Velocity Operating Frequency Operation Condition
AR850
10mm 5MHz 10mm 2.5MHz 1.2~225mm(Steel) ±(1%H±0.1mm) 0.1mm 1000~9999m/s 5MHz / 2.5MHz 0°C~40°C
Minimum Limit For Tube Measuring
20 x 3mm(Steel)
Data Storage
10 groups
Sound Velocity Measuring & Storage
12 groups
Backlight Display
Auto Zero Calibration
Auto linear compensation
Coupling Indicator
Battery Indication
Auto/Manual Power Off
Max / Min Thickness Alarm Setup
—
12 Sound Velocities For Diff. Material
—
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power
3*1.5V AAA batteries
Product Net Weight
275g
Product Size
153 x 75 x 35mm
Packing
Gift box
Std Quantity / Carton
12
Std Carton Size
52 x 43 x 32.5cm
Std Carton G· Weight
16.3kg
AR860
6mm 5MHz 10mm 5MHz 1.00~300mm(Steel) ±(1%H±0.1mm) 0.1mm 1000~9999m/s 5MHz 0°C~40°C 15 x 2mm(Steel) (6)
20 x 3mm(Steel) (10) 12 groups 12 groups
3*1.5V AAA batteries 275g
153 x 75 x 35mm Gift box 12
52 x 43 x 32.5cm 16.3kg
Film / Coating Thickness Gauge
SPECIFICATIONS AR930
AR931
Measuring Range Measuring Principle
0~1800m Magnetic Induction
Accuracy
±(3%H±1m)
Resolution
0.1m / 1m
Minimum Curvature Radius
Convex=1.5mm Concave=9mm
Base Sample Diameter
7mm
Base Substrate Thickness
0.5mm
Auto-identify Substrate Material
—
—
Backlight Display
Alarm Buzzer
Zero / Two Point / Basic Calibration
Single / Continuous / Standard Deviation Measurement
Data Storage & Recall
Data Analysis
Max & Min Measuring
AVG & DFR Measuring
Data Storage
15 groups
15 groups
Metric / Imperial Switchable
Battery Indication
Auto Power Off
Operation Condition
0°C~40°C (without strong magnetic)
GENERAL CHARACTERISTICS & PACKING INFORMATION
Power
9V battery
9V battery
Product Net Weight
147g
245g
Product Size
183 x 67 x 30mm 153 x 75 x 35mm
Packing
Aluminum Box Aluminum Box
Std Quantity / Carton
12
12
Std Carton Size
52 x 43 x 32.5cm 52 x 43 x 32.5cm
Standard Carton Gross Weight
13.5kg
13.5kg
AR932
0~1500m Magnetic Induction & Eddy current
±(1.8%um±2um)(0-500um) ; ±(2.2%um±2um) (500-1500um)
0.1m / 1m Convex=5mm Concave=30mm
25x25mm Magnetic : 0.2mm ; Non-magnetic : 0.05mm
20 groups 0°C~50°C (without strong magnetic)
2*1.5V AAA batteries 75g
119 x 50 x 30mm Gift box 40
52.5 x 40 x 49cm 20kg
www.neonics.co.th
Tel: 02-077-7602 061-8268939 E-mail: [email protected] [email protected]
Ultrasonic Thickness
Gauge
AR850
1.2~225mm
Ultrasonic Thickness
Gauge
AR860
1.0~300mm
Film / Coating Thickness Gauge
AR930
0~1800m
Film / Coating Thickness Gauge
AR931
0~1800m
Film / Coating Thickness Gauge AR932
0~1500m
14