Smart Sensor As840 Ultrasonic Thickness Gauge Installation Guide

AS840 Ultrasonic Thickness Gauge

Product Information

Ultrasonic Thickness Gauge

The Ultrasonic Thickness Gauge is available in three models:
AS840, AS850, and AS860. It is designed to measure the thickness of
various materials, with a measuring range of 1.2mm to 225mm
(Steel). The gauge operates at a frequency of 5MHz and has an
accuracy resolution of 1000~9999m/s. It features sound velocity
measuring and storage capabilities, with the ability to store up to
12 groups of data. The gauge also includes a backlight display,
auto zero calibration, auto linear compensation, coupling
indicator, and battery indication. It can be powered by a 9V
battery and has a net weight of 200g.

Differential Pressure Meter Film / Coating Thickness Gauge

The Differential Pressure Meter Film / Coating Thickness Gauge
is available in two models: AS510 and AS930. It is designed to
measure differential pressure and film/coating thickness. The AS510
model has a measuring range of hPa, mbar, mmH2O, mmHg, inH2O, inHG,
m/s, fpm, while the AS930 model has a measuring range of 0~1800m.
Both models operate on 3*1.5V AAA batteries and feature a backlight
display, alarm buzzer, zero/two-point/basic calibration,
single/continuous/standard deviation measurement, data storage and
recall, data analysis, and metric/imperial switchable units.

Film / Coating Thickness Gauge

The Film / Coating Thickness Gauge is available in two models:
AS931 and AS931. Both models have a measuring range of 0~1800m and
operate on a 9V battery. They feature a measuring principle of
magnetic induction, with an accuracy resolution of 0.1m/1m. The
gauges have a minimum curvature radius of Convex=1.5mm and
Concave=9mm, a base sample diameter of 7mm, and a base substrate
thickness of 0.5mm. They also include a backlight display, alarm
buzzer, zero/two-point/basic calibration,
single/continuous/standard deviation measurement, data storage and
recall, data analysis, max & min measuring, AVG & DFR
measuring, and metric/imperial switchable units.

Product Usage Instructions

Ultrasonic Thickness Gauge

  1. Ensure the gauge is powered by inserting a 9V battery.
  2. Select the desired model: AS840, AS850, or AS860.
  3. Place the transducer on the material surface to be
    measured.
  4. Read the thickness measurement displayed on the gauge.
  5. If necessary, store the measurement data by pressing the
    appropriate storage button.
  6. Perform sound velocity measurements and storage as needed.
  7. Use the backlight display for better visibility in low light
    conditions.
  8. Perform auto zero calibration and auto linear compensation when
    required.
  9. Monitor the coupling indicator to ensure proper contact between
    the transducer and material surface.
  10. Check the battery indication to ensure sufficient power for
    accurate measurements.
  11. Choose between auto or manual power off options for
    convenience.
  12. If needed, set up max/min thickness alarms for specific
    measurement requirements.
  13. Refer to the user manual for specific instructions on using the
    gauge with different materials and switching between metric and
    imperial units.

Differential Pressure Meter Film / Coating Thickness Gauge

  1. Insert 3*1.5V AAA batteries to power the gauge.
  2. Select the desired model: AS510 or AS930.
  3. Place the gauge in the desired measurement location.
  4. Read the differential pressure or film/coating thickness
    measurement displayed on the gauge.
  5. Use the backlight display for better visibility in low light
    conditions.
  6. Be aware of alarm buzzers indicating specific conditions or
    thresholds.
  7. Perform zero/two-point/basic calibration as required for
    accurate measurements.
  8. Select the appropriate measurement mode: single, continuous, or
    standard deviation.
  9. Store and recall measurement data as needed, and perform data
    analysis if required.
  10. Refer to the user manual for specific instructions on using the
    gauge with different units and power management settings.

Film / Coating Thickness Gauge

  1. Insert a 9V battery to power the gauge.
  2. Select the desired model: AS931 or AS931.
  3. Place the gauge in the desired measurement location.
  4. Read the film/coating thickness measurement displayed on the
    gauge.
  5. Use the backlight display for better visibility in low light
    conditions.
  6. Be aware of alarm buzzers indicating specific conditions or
    thresholds.
  7. Perform zero/two-point/basic calibration as required for
    accurate measurements.
  8. Select the appropriate measurement mode: single, continuous, or
    standard deviation.
  9. Store and recall measurement data as needed, and perform data
    analysis if required.
  10. Switch between metric and imperial units based on the
    measurement requirements.
  11. Monitor the battery indication to ensure sufficient power for
    accurate measurements.
  12. Enable auto power off for power-saving purposes.
  13. Refer to the user manual for specific instructions on using the
    gauge with different materials and measurement scenarios.

Ultrasonic Thickness Gauge

SPECIFICATIONS

AS840

AS850

Transducer Measuring Range

10mm 5MHz 1.2~225mm(Steel)

10mm 5MHz / 2.5MHz 1.2~225mm(Steel)

Accuracy Resolution Sound Velocity

±(1%H±0.1mm) 0.1mm
1000~9999m/s

±(1%H±0.1mm) 0.1mm
1000~9999m/s

Operating Frequency

5MHz

5MHz

Operation Condition Minimum Limit For Tube Measuring

0°C~40°C

0°C~40°C 20*3mm(Steel)

Thickness Data Storage

10 groups

10 groups

Sound Velocity Measuring & Storage
Backlight Display Auto Zero Calibration Auto linear compensation Coupling Indicator Battery Indication

12 groups

12 groups

Auto/Manual Power Off

Max / Min Thickness Alarm Setup

12 Sound Velocities For

Different Material

Metric / Imperial Switchable

GENERAL CHARACTERISTICS & PACKING INFORMATION

Power Product Net Weight Product Size Packing Standard Quantity / Carton
Standard Carton Size Standard Carton Gross Weight

9V battery 200g
150 x 80.5 x 34mm Gift box 24
47 x 38 x 55cm 19.5kg

9V battery 210g
150 x 80.5 x 34mm Gift box 10
39x 32 x 44cm 11.0kg

AS860
6mm 5MHz / 10mm 5MHz 1.2~225mm(Steel) ±(1%H±0.1mm) 0.1mm 1000~9999m/s 5MHz 0°C~40°C
12 groups 12 groups

9V battery 240g
150 x 80.5 x 34mm Gift box 10
39x 32 x 44cm 11.0kg

Differential Pressure Meter Film / Coating Thickness Gauge

SPECIFICATIONS

AS510

Measuring Range

0~100hPa 0~45.15 inH²O

Accuracy

±0.03 hPa(0~0.30hPa)
±0.05 hPa(0.31~1.0hPa) ±(1.5%+0.1hPa) remaining ±0.01 inH²O(0.00~0.12inH²O) ±0.02 inH²O(0.13~0.40inH²O) ±(1.5%+0.4inH²O) remaining

Resolution
Measuring speed

0.01hPa / 0.01inH²O 0.5 sec

Units

hPa, mbar, mmH2O, mmHg, inH2O, inHG, m/s, fpm

Operation Condition

0~50°C / 32~122°F

GENERAL CHARACTERISTICS & PACKING INFORMATION

Power Product Net Weight Product Size Packing Standard
Quantity / Carton
Standard Carton
Size

3*1.5V AAA batteries 71.5g
124.8 x 49.8 x 25.6mm Gift box 40
52.5 x 40 x 49cm

Standard Carton Gross Weight

19.01kg

SPECIFICATIONS AS930

AS931

Measuring Range Measuring Principle Accuracy Resolution Minimum Curvature Radius
Base Sample Diameter
Base Substrate Thickness
Backlight Display Alarm Buzzer Zero / Two Point / Basic Calibration Single / Continuous / Standard
Deviation Measurement Data Storage & Recall Data Analysis Max & Min Measuring AVG & DFR Measuring Data Storage Metric / Imperial Switchable
Battery Indication Auto Power Off Operation Condition

0~1800m

Magnetic Induction

±(3%H±1m)

0.1m / 1m

Convex=1.5mm Concave=9mm

7mm

0.5mm

15 groups

15 groups

0°C~40°C (without strong magnetic)

GENERAL CHARACTERISTICS & PACKING INFORMATION

Power Product Net Weight Product Size Packing Standard Quantity / Carton
Standard Carton Size Standard Carton Gross Weight

9V battery 147g
183 x 67 x 30mm Gift box 10
39 x32 x 44cm 9.35kg

9V battery 155g
159 x 66 x 31mm Gift box 10
39 x 32 x 44cm 9.8kg

www.neonics.co.th

Tel: 02-077-7602 061-8268939 E-mail: [email protected] [email protected]

Ultrasonic Thickness
Gauge AS850
1.2~225mm

Ultrasonic Thickness
Gauge AS860
1.2~225mm

Ultrasonic Thickness
Gauge AS840
1.2~225mm

Differential Pressure
Meter AS510
0~100hPa 0~40.15inH²O

Film / Coating Thickness Gauge
AS930
0~1800m

Film / Coating Thickness Gauge AS931
0~1800m
6

Ultrasonic Thickness Gauge

SPECIFICATIONS
Transducer Measuring Range Accuracy Resolution Sound Velocity Operating Frequency Operation Condition

AR850
10mm 5MHz 10mm 2.5MHz 1.2~225mm(Steel) ±(1%H±0.1mm) 0.1mm 1000~9999m/s 5MHz / 2.5MHz 0°C~40°C

Minimum Limit For Tube Measuring

20 x 3mm(Steel)

Data Storage

10 groups

Sound Velocity Measuring & Storage

12 groups

Backlight Display

Auto Zero Calibration

Auto linear compensation

Coupling Indicator

Battery Indication

Auto/Manual Power Off

Max / Min Thickness Alarm Setup

12 Sound Velocities For Diff. Material

GENERAL CHARACTERISTICS & PACKING INFORMATION

Power

3*1.5V AAA batteries

Product Net Weight

275g

Product Size

153 x 75 x 35mm

Packing

Gift box

Std Quantity / Carton

12

Std Carton Size

52 x 43 x 32.5cm

Std Carton G· Weight

16.3kg

AR860
6mm 5MHz 10mm 5MHz 1.00~300mm(Steel) ±(1%H±0.1mm) 0.1mm 1000~9999m/s 5MHz 0°C~40°C 15 x 2mm(Steel) (6)
20 x 3mm(Steel) (10) 12 groups 12 groups
3*1.5V AAA batteries 275g
153 x 75 x 35mm Gift box 12
52 x 43 x 32.5cm 16.3kg

Film / Coating Thickness Gauge

SPECIFICATIONS AR930

AR931

Measuring Range Measuring Principle

0~1800m Magnetic Induction

Accuracy

±(3%H±1m)

Resolution

0.1m / 1m

Minimum Curvature Radius

Convex=1.5mm Concave=9mm

Base Sample Diameter

7mm

Base Substrate Thickness

0.5mm

Auto-identify Substrate Material

Backlight Display

Alarm Buzzer

Zero / Two Point / Basic Calibration

Single / Continuous / Standard Deviation Measurement

Data Storage & Recall

Data Analysis

Max & Min Measuring

AVG & DFR Measuring

Data Storage

15 groups

15 groups

Metric / Imperial Switchable

Battery Indication

Auto Power Off

Operation Condition

0°C~40°C (without strong magnetic)

GENERAL CHARACTERISTICS & PACKING INFORMATION

Power

9V battery

9V battery

Product Net Weight

147g

245g

Product Size

183 x 67 x 30mm 153 x 75 x 35mm

Packing

Aluminum Box Aluminum Box

Std Quantity / Carton

12

12

Std Carton Size

52 x 43 x 32.5cm 52 x 43 x 32.5cm

Standard Carton Gross Weight

13.5kg

13.5kg

AR932
0~1500m Magnetic Induction & Eddy current
±(1.8%um±2um)(0-500um) ; ±(2.2%um±2um) (500-1500um)
0.1m / 1m Convex=5mm Concave=30mm
25x25mm Magnetic : 0.2mm ; Non-magnetic : 0.05mm

20 groups 0°C~50°C (without strong magnetic)
2*1.5V AAA batteries 75g
119 x 50 x 30mm Gift box 40
52.5 x 40 x 49cm 20kg

www.neonics.co.th

Tel: 02-077-7602 061-8268939 E-mail: [email protected] [email protected]

Ultrasonic Thickness
Gauge
AR850
1.2~225mm

Ultrasonic Thickness
Gauge
AR860
1.0~300mm

Film / Coating Thickness Gauge
AR930
0~1800m

Film / Coating Thickness Gauge
AR931
0~1800m

Film / Coating Thickness Gauge AR932
0~1500m

14

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals