EVERBILT HDEFR50W Effluent Pump User Guide - Ensure basin is clear of all debris and place pump on hard level

  1. Ensure basin is clear of all debris and place pump on hard level surface (not dirt or gravel). 30″ x 18″ minimum basin requirement.
    EVERBILT HDEFR50W Effluent Pump User Guide - Measure, cut and install discharge fittings
  2. Measure, cut and install discharge fittings, check valve, and piping. Drill a 1/8″ hole in the discharge pipe about 2″-3″ above the pump discharge connection.
    EVERBILT HDEFR50W Effluent Pump User Guide - Plug Pump in to GFCI outlet on dedicated circuit
  3. Plug Pump in to GFCI outlet on dedicated circuit with 15 amp breaker
    EVERBILT HDEFR50W Effluent Pump User Guide - Test operation by filling the basin above the Float Switch Operation
  4. Test operation by filling the basin above the Float Switch Operation ON Height to make the pump start pumping out. When the water reaches below the Float Switch Operation OFF Height, ensure it stops pumping.
    EVERBILT HDEFR50W Effluent Pump User Guide - Install optional basin cover
  5. Install optional basin cover.