Neutrik Nl2fxx-w Loudspeaker Cable Connector Instruction Manual

NL2FXX-W Loudspeaker Cable Connector

Product Information

The product is a speakON Cable Connector with model numbers
NL2FXX-W-* and NL4FXX-W-*. It is designed for factory assembly only
and has approval ratings based on EN/IEC and UL/CSA standards. The
product is rated at 250V AC and 30A. It supports wire sizes ranging
from 1.0mm2 to 4.0mm2 for NL2FXX-W-* model and 16-11 AWG for
NL4FXX-W-* model. The cable outer diameter supported is 6.0 – 12.0
mm (0.24 – 0.47 inches) for NL2FXX-W-* and 10.0 – 16.0 mm (0.39 –
0.63 inches) for NL4FXX-W-*.

Assembly Instructions

To assemble the speakON Cable Connector, follow the steps
below:

  1. Place the bushing (1) and chuck (2) over the cable.
  2. Prepare the cable as shown in the manual.
  3. Slide the cable into the contacts and clamp it.
  4. Position the chuck (1) on the insert (2).
  5. Slide the insert (2) with chuck (1) together into the housing
    (3).
  6. Slide the bushing (4) over the chuck (1).
  7. Use a torque wrench with a 27 mm (1 1/8 inch) hex bit and
    tighten it with 2.5 Nm (22 inch pound / 1.8 lb-ft).

Disassembly Instructions

To disassemble the speakON Cable Connector, use the Neutrik tool
HTLACB. Position the tool on the surfaces and open the clamping
sleeve.

Safety Information

Ensure that the connection is not exposed to bending forces and
do not attach loads to the cable or have free-dangling cable
windings. The connector must be replaced in case of any broken
parts or excessive wear and tear.

More Information

For more information, visit the Neutrik
website
.

R
ASSEMBLY INSTRUCTION
speakON® | Loudspeaker Cable Connector
NL2FXX-W-* & NL4FXX-W-*

A IMPORTANT SAFETY INFORMATION

ATTENTION: speakON® IS NOT TO BE USED AS AN AC MAINS OR POWER SUPPLY CONNECTOR! CAUTION: CONNECTOR NOT TO BE ENGAGED AND DISENGAGED IN NORMAL USED WHEN LIVE
OR UNDER LOAD. ATTENTION: NE PAS UTILISER POUR COUPER LE COURANT PRODUCT IS INTENDED FOR FACTORY ASSEMBLY ONLY

Approval based:
Rating: Wire size: Cable O.D.:

EN / IEC EN 61984 IEC 61984

250 V ac / 30 A

1.0 – 4.0 mm2

*-S:

6.0 – 12.0 mm (0.24 – 0.47″)

*-L: 10.0 – 16.0 mm (0.39 – 0.63″)

UL / CSA UL 1977 CAN/CSA C22.2 No.182.3
250 V ac / 30 A 16 – 11 AWG
6.0 – 12.0 mm (0.24 – 0.47″) 10.0 – 16.0 mm (0.39 – 0.63″)

B ASSEMBLY INFORMATION

A

2.

1.

A Place the bushing (1) and chuck (2) over the cable.
Important: Chuck and Bushing cannot be placed over the cable after the assembly or the insert.

B

CABLE PREPARATION: 2 POLE

B
Prepare the cable as shown. CABLE PREPARATION: 4 POLE

27 mm [1.06″]

9 mm
[0.35″]

27 mm [1.06″]

9 mm
[0.35″]

C

Torx size Torque Value 0.7 Nm

T8

(6.2 inch pound)

BDA 638

C Slide the cable into the contacts and clamp

WIRING: 2 POLE 1+

WIRING: 4 POLE

1+

2-

1-

1-

2+

ð
Page 1

ASSEMBLY INSTRUCTION – speakON Cable Connector I NL2FXX-W-* & NL4FXX-W-*
D
3

2.

Important: Push and turn simultaneously.
4
E
8

1.

D Position chuck (1) on insert (2).
E Slide insert (2) with chuck (1) together into housing (3) . Important: Align the chuck by positioning the nose into keyway.
Slide bushing (4) over chuck (1).

27 mm 1 1/8 inch Hex bit
Neutrik HTLACA 5

7
Torque Value 2.5 Nm (22 inch pound / 1.8 lb-ft)

4 6

BDA 638

Neutrik HTLACB

Hold the connector with the NEUTRIK tool (5) and tighten bushing with the NEUTRIK tool (6) as shown.
For an exact mounting position use a torque wrench with 27 mm (1 1/8 inch) hex bit (7) and tighten it with 2.5 Nm (22 inch pound / 1.8 lb-ft).

NEUTRIK tool Information: (5) HTLACA (6) HTLACB

ð
Page 2

ASSEMBLY INSTRUCTION – speakON Cable Connector I NL2FXX-W-* & NL4FXX-W-*
C FINISHED CONNECTOR

NL2FXX-W-*
D DISASSEMBLY INFORMATION FOR DISASSEMBLY!
1. Use the Neutrik tool HTLACB. 2. Position the tool on the surfaces and open the
clamping sleeve.
HTLACB
E SAFETY INFORMATION CAUTION To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no freedangling cable windings etc.).
SAFETY WARNING For safety and certification reasons the connector must be replaced in case of any broken parts or excessive wear and tear.
F More Information on the www.neutrik.com
https://www.neutrik.com/products/audio/speakon

NL4FXX-W-*
LIECHTENSTEIN
FORCE

Neutrik AG Neutrik USA Inc. Neutrik (UK) Ltd. Neutrik Vertriebs GmbH

LI USA UK DE / NL / AT/DK

T: +423 / 237 24 24 T: +1 704 / 972 3050 T: +44 1983 / 811 441 T: +49 8131 / 280 890

F: +423/232 53 93 F: +1 704/438 9202 F: +44 1983 / 811 439 F: +49 8131/280 830

Neutrik France

FR

Neutrik Tokyo Ltd.

JP

Neutrik Hong Kong Ltd. HK

T: +33 1 /4131 6750 T: +81 3 /3663 4733 T: +852 /2687 6055

F: +33 1/ 4131 0511 F: +81 3/3663 4796 F: +852/2687 6052

I I Draft. Nr.: BDA 638 V2 Update: 2022-08-11 Data subject to change without prior notice. © 2022 NEUTRIK®. NEUTRIK® are registered trademark of Neutrik AG. ALL RIGHTS RESERVED.

R

www.neutrik.com

Page 3

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals