Develco Products F0067z0400 Intelligent Smoke Alarm Instruction Manual

F0067Z0400 Intelligent Smoke Alarm

Product Information

Product ReferenceF0067Z0400
Product DescriptionThe Intelligent Smoke Alarm is designed to warn occupants about
smoke using a loud siren. It can instantly notify users of
potential fires through an internet-connected gateway when they are
away. The smoke alarm reports its status and temperature every two
minutes via the IoT system. It is suitable for use in private
homes, camping trailers, mobile homes, and caravans, but not
recommended for boats or places where damp, gases, and smoke
naturally occur.

Product Usage Instructions

  1. Pull out the battery isolation strip to activate the
    Intelligent Smoke Alarm.
  2. The Intelligent Smoke Alarm will start searching for a Zigbee
    network to join. This process may take up to 15 minutes.
  3. Ensure that the Zigbee network is open for joining devices and
    will accept the Intelligent Smoke Alarm.
  4. While searching for a Zigbee network, the LED button will flash
    red.
  5. Once the LED button stops flashing, it indicates that the
    Intelligent Smoke Alarm has successfully joined the Zigbee
    network.
  6. Select the recommended location for placement based on the
    provided examples:
Recommended LocationPlacement Examples
Living RoomBedroom
GarageHallway
BathroomKitchen
BedroomHall
Living RoomBasement
BedroomBathroom
Kitchen
  1. For ceiling placement, ensure that the smoke alarm is at least
    50 cm away from the wall.
  2. For wall placement, the smoke alarm should be between 30 and 50
    cm from the ceiling.
  3. There should be at least one smoke alarm per floor, and the
    maximum distance between smoke alarms should be 10 meters.
  4. To mount the smoke alarm:
  1. Detach the alarm from the mounting base by twisting
    counterclockwise.
  2. Use the mounting base ring to mark the screw holes on the
    ceiling or wall.
  3. Install the mounting base in the marked position using the
    enclosed screws and plugs.
  4. Ensure that the battery is properly inserted before attaching
    the alarm to the mounting base.
  5. Attach the alarm by twisting clockwise until it clicks.

To reset the smoke alarm:

  1. Detach the alarm from the mounting base by twisting it
    counterclockwise.
  2. Press and hold the LED button.
  3. While holding the button, the LED will flash once, then twice
    in a row, and finally numerous times in a row.
  4. Release the button while the LED is flashing numerous times in
    a row.
  5. After releasing the button, the LED will show one long flash to
    indicate that the reset is completed.

The Intelligent Smoke Alarm has the following modes:

ModeDescription
Searching Gateway ModeThe red LED light in the back of the device will flash every
second for up to 15 minutes while searching for a gateway.
Normal ModeThe front LED will flash every 45 seconds to indicate normal
operation.
Alarm ModeWhen smoke is detected, the LED will flash rapidly, and the
device will emit a loud alarm sound. Press the button on top of the
alarm to acknowledge and stop the siren. The alarm will be blocked
for the following 10 minutes to allow time for smoke
ventilation.

eng Intelligent Smoke Alarm
Product reference F0067Z0400
INSTALLATION MANUAL
Version 3.0
Product description The Intelligent Smoke Alarm will warn occupants about smoke, using a loud siren. While away, they will be instantly notified of a potential fire through an internet-connected gateway. The Intelligent Smoke Alarm will report the status and temperature every two minutes via your IoT system. The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans. It is not recommended for boats.
Precautions · Do not remove the product label as it
contains important information. · Do not paint the alarm. · Avoid placing the Intelligent Smoke Alarm
in dusty rooms. · Do not place the alarm in a kitchen, garage,
or in other places where damp, gases and smoke naturally occur.

Getting started 1. Pull out the battery isolation strip as shown. a.
LAPBREOLDUCT
CR123
2. The Intelligent Smoke Alarm will now start searching (up to 15 minutes) for a Zigbee network to join.
3. Make sure that the Zigbee network is open for joining devices and will accept the Intelligent Smoke Alarm.
4. While the Intelligent Smoke Alarm is searching for a Zigbee network to join, the LED button flashes red.
b.

· Rooms larger than 80 m2 require several smoke alarms in order to sustain full fire safety.
· The alarm should be placed within reach for battery testing and maintenance.
· The alarm should not be placed at the top of high pointed ceilings or in ceiling corners or within 50 cm of a wall.
d. PLACEMENT EXAMPLES

Living Room

Bedroom

Garage

Hallway Bathroom Kitchen

RECOMMENDED LOCATION

Bedroom Hall Living Room Basement

Bedroom Bathroom Kitchen

5. When the LED button stops flashing, the Intelligent Smoke Alarm has successfully joined the Zigbee network.
c.

RECOMMENDED LOCATION

CEILING PLACEMENT
The smoke alarm should be a minimum of 50 cm from the wall.
e. ceiling

min 50 cm

wall

Placement
· Place the Intelligent Smoke Alarm indoors at a temperature between 0-50*C.
· It is important to place smoke alarms in bedrooms and on exit routes.
· The distance between the smoke alarm and walls, ventilation or other obstacles, should be at least 50 cm.
· The distance between the alarm and a fireplace or stove should be at least 4 meters.

WALL PLACEMENT The smoke alarm should be between 30 and 50 cm from the ceiling.

f.

ceiling

wall

min 30 cm max 50 cm

There should be at least one smoke alarm per floor and a maximum distance between smoke alarms of 10 meters.
g.

max 10 m

Living Room

Bedroom

Garage
Mounting

Bathroom Kitchen

1. Detach the alarm from the mounting base by twisting counterclockwise.

2. Use the mounting base ring to mark the screw holes on the ceiling or on the wall.

h.

3. Use enclosed screws and plugs to install the mounting base in the marked position.
i.

4. If the battery is missing or inserted incorrectly, it will be impossible to attach the alarm in the mounting base.
5. Attach the alarm by twisting clockwise until it clicks.
j.
Testing · Always test the working order of the
smoke alarm after installation or battery change. · When pressing the alarm button, the alarm sound should be heard.

· A network alarm test can be performed

by holding down the alarm button for at least 6.5 seconds (count 2 sets of 3 sound

sweeps).

k.

· A test message will be sent over the Zigbee network.

· Test all of your alarms once a week to ensure they are functioning correctly.

Resetting
Resetting is needed it you want to connect your smoke alarm to another gateway or if you need to perform a factory reset to eliminate abnormal behavior.
STEPS FOR RESETTING
1. Detach the alarm from the mounting base by twisting it counterclockwise.
2. Press and hold the LED button.
3. While you are holding the button down, the LED first flashes once, then two times in a row, and finally numerous times in a row.
4. Release the button while the LED is flashing numerous times in a row.
5. After you release the button, the LED shows one long flash, and the reset is completed.

l.

Modes
SEARCHING GATEWAY MODE Red LED light in the back of the device is flashing every second (up to 15 minutes)
NORMAL MODE Front LED is flashing every 45 seconds.
ALARM MODE When smoke is detected, the LED will speed up flashes, and simultaneously, the device will emit a loud alarm sound. Press the “button/ top” of the alarm to acknowledge and stop the siren. The following 10 minutes, it will block alarms, allowing time to ventilate the smoke.

LOW BATTERY MODE Simultaneous audible signals and front LED flashes every 45 seconds means that the battery should be replaced.
REPLACE DEVICE MODE When audible signals and front LED flashes are not simultaneous, the device should be replaced. The life expectancy of smoke alarms is generally 10 years, after which their sensors begin to lose sensitivity.
Fault finding & cleaning · Dust particles in the smoke chamber can
be removed by vacuuming the mesh. · High humidity condensing can be resolved
by drying the smoke alarm. · If the smoke alarm does not work when the
test button is pushed, the probable cause is a faulty battery. Replace the battery if it is worn out. · In case of a bad or weak signal, change the location of the smoke alarm. Otherwise you can relocate your gateway or strengthen the signal with a smart plug. · If the search for a gateway has timed out, a short press on the LED button will restart it.
Battery replacement
CAUTION: RISK OF EXPLOSION IF BATTERIES ARE REPLACED BY AN INCORRECT TYPE. DISPOSE OF THE BATTERIES IN ACCORDANCE WITH INSTRUCTIONS.
CAUTION: When removing cover for battery change – Electrostatic Discharge (ESD) can harm electronic components inside. 1. To replace the battery, detach the smoke
alarm from the mounting base by twisting counter-clockwise. 2. Replace the battery respecting the polarities. The Intelligent Smoke Alarm uses 1xCR123 battery.

m.
3. Attach the alarm in the mounting base by twisting clockwise until it clicks, and test the alarm.
n.
Disposal Dispose the product and battery properly at the end of life. This is electronic waste which should be recycled.
Other information · Note local country regulations regarding
installation of mains powered alarms in new buildings. · Note local regulations about information to your insurance company regarding installed smoke alarms.
CE certification The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product and, in particular, its compliance with the harmonized specifications of standard EN14604:2005/AC:2008 relating to Construction Products Regulation 305/2011.
IN ACCORDANCE WITH THE DIRECTIVES · Radio Equipment Directive (RED)
2014/53/EU · RoHS Directive 2015/863/EU amending
2011/65/EU
2 1
1116
EN14604 : 2005 + AC:2008 DoP no.: F0067Z0400
The paper version of the DoP is available free of charge on request Declared performances 4.14-4.19+5.2-5.24: Passed Dowload DoP document: www.develcoproducts.com

Other certifications · Zigbee 3.0 certified
All rights reserved. Develco Products assumes no responsibility for any errors, which may appear in this manual. Furthermore, Develco Products reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and Develco Products does not make any commitment to update the information contained herein. All the trademarks listed herein are owned by their respective owners.
Copyright © Develco Products A/S
Distributed by Develco Products A/S Tangen 6 8200 Aarhus N Denmark www.develcoproducts.com
Smoke alarm manufactured by CAVIUS Aps Julsøvej 16 8660 Silkeborg Denmark. Manufactured in P.R.C.
By

F0067Z0400 (T00000046) v2.8

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals