Maretron Pts-0-1.5psi-01 Submersible Pressure Transducers Instruction Manual

PTS-0-1.5PSI-01 Submersible Pressure Transducers

Product Information

The PTS-0-1.5PSI-01, PTS-0-3PSI-01, and PTS-0-5PSI-01 are
submersible pressure transducers designed for tanks with a 5-Hole
SAE J1810 fitting at the top. The transducers can be mounted inside
a restraining tube or focus tube (sold separately, Maretron part
number TFT-5H) and are compatible with Maretron DSM Series Display
(firmware 1.4.7 or higher) or a PC running Maretron’s N2KAnalyzer
software (version 1.4.19 or higher). The transducers have a cable
length of 16.4 ft (5 m) for PTS-0-1.5PSI-01 and PTS-0-3PSI-01 while
PTS-0-5PSI-01 has a cable length of 23.0 ft (7 m).

Product Usage Instructions

  1. Install the mounting plate with cord grip onto the transducer
    cable, with the rounded hex section of the cord grip facing away
    from the transducer.
  2. Lower the pressure transducer into the tank such that the
    transducer lies at the lowest point of the tank, and tighten the
    cord grip to secure the cable. On a tank with a flat bottom, the
    transducer may slide from side to side with the motion of the
    vessel, but will not rotate due to the stiffness of the cable.
  3. If necessary, mount the pressure transducer inside a
    restraining tube or focus tube (sold separately, Maretron part
    number TFT-5H). Refer to Figure 1 for examples.
  4. Use a Maretron DSM Series Display (firmware 1.4.7 or higher) or
    a PC running Maretron’s N2KAnalyzer software (version 1.4.19 or
    higher), to configure the connected channel(s) on the FPM100.
  5. Supply power to the NMEA 2000 network and verify that the
    pressure channel indicates a valid pressure reading.

Installation Instructions
PTS-0-1.5PSI-01, PTS-0-3PSI-01, PTS-0-5PSI-01 Submersible Pressure Transducers
WARNING ­ Maretron submersible pressure transducers are not approved for use with gasoline. If you wish to use the FPM100 to monitor pressures or levels of gasoline, you must obtain a pressure transducer that is approved for use with gasoline.
Maretron’s submersible pressure transducers are used for indicating tank levels and can be installed directly in the tank. Please follow these instructions to mount and connect a submersible pressure transducer to an NMEA 2000® network via a Maretron FPM100 Fluid Pressure Monitor. Maretron recommends one of two methods for mounting a submersible pressure transducer in a tank; 1) without a restraining tube (shown on left side of Figure 1) and, 2) with a restraining tube (shown on right side of figure 1).
1. The submersible pressure transducers are designed for a tank with a 5-Hole SAE J1810 fitting at the top. Install the mounting plate with cord grip onto the transducer cable, with the rounded hex section of the cord grip facing away from the transducer.
2. Lower the pressure transducer into the tank such that the transducer lies at the lowest point of the tank, and tighten the cord grip to secure the cable. On a tank with a flat bottom, the transducer may slide from side to side with the motion of the vessel, but will not rotate due to the stiffness of the cable. It is also possible to mount the pressure transducer inside a restraining tube or focus tube (sold separately, Maretron part number TFT-5H). Please refer to Figure 1 for examples.
Mounting Screws (x5)
Mounting Plate w/Cord Grip
Mounting Plate Gasket Focus Tube
Focus Tube Gasket
SAE 5-Bolt Tank Fitting

3. Connect the two wires of the pressure transducer to a free pressure monitoring channel as shown in Figure 2 below. The diagram shows a connection to FPM100 channel #0, but connections to other channels are similar. Connect the white wire from the pressure transducer to the positive (+) terminal of the channel and connect the brown wire from the pressure transducer to the negative (-) terminal of the channel. The example in Figure 1 shows the pressure transducer connected to switch channel 0 with the white wire connected to “P0+”, and the brown wire connected to “P0-“. Submersible pressure transducers have a small plastic vent tube in the connecting cable. Care must be taken not to kink or block this tube or pressure readings will be inaccurate.

Brown

White

FPM100
1 2 3 4 5 6 7 8 9 10 11 12

FPM100 Screw Terminals
Submersible Pressure Transducer

P5­

P5+

P4­

P4+

P3­

P3+

P2­

P2+

P1­

P1+

P0­

P0+

Figure 2 ­ Submersible Pressure Transducer Connection Diagram

4. Use a Maretron DSM Series Display (firmware 1.4.7 or higher) or a PC running Maretron’s N2KAnalyzer software (version

1.4.19 or higher), to configure the connected channel(s) on the FPM100.

PTS-0-1.5PSI-01

PST-0-3PSI-01

PST-0-5PSI-01

Value at 4mA: 0 PSI (0 bar)

0 PSI (0 bar)

0 PSI (0 bar)

Value at 20mA: 1.5 PSI (0.103 bar) 3.0 PSI (0.207 bar) 5.0 PSI (0.345 bar)

5. Supply power to the NMEA 2000 network and verify that the pressure channel indicates a valid pressure reading.
Copyright© 2022 Carling Technologies Inc., now part of Littelfuse – All rights reserved P/N: M003088 Rev. 2.3 11/22

Mechanical Drawing

M22x1.5 Ø 25 mm (0.98 “)

95.5 mm (3.76″)

Pressure Transducer Specifications

Part Number

Operating Range

PTS-0-1.5PSI-01 PTS-0-3PSI-01 PTS-0-5PSI-01

0 to 1.5 PSI (0.103 bar) 0 to 3 PSI (0.207 bar) 0 to 5 PSI (0.345 bar)

Depth Range

Water (1,000 kg/m3) Diesel (820 kg/m3)

41.5″ (1.05 m)

50.7″ (1.29 m)

83.1″ (2.11 m)

101.3″ (2.57 m)

138.4″ (3.51 m)

168.9″ (4.29 m)

Cable Length
16.4 ft (5 m) 16.4 ft (5 m) 23.0 ft (7 m)

Specification Sensor Type Output Excitation Voltage Compatible Fluids / Gases
Operating Temperature Ambient Temperature Accuracy Total Error Band (TEB) Non-Linearity, Hysteresis (NLH) Temperature Compensation Zero Point and Span Long Term Stability Rise Time Switch-On Delay Over Pressure Burst Pressure Vibration Shock Construction
Minimum Cable Bend Radius EMC Compatibility Weight

Value Gauge (Vent Tube) 4 ­ 20 mA current loop, loop powered 9 VDC to 32 VDC Diesel, Diesel Exhaust Fluid (DEF), Hydraulic Fluid, Kerosene, Motor Oil, Fresh Water, Sea Water, Waste Water 14°F to 158°F (-10°C to 70°C) 14°F to 158°F (-10°C to 70°C) ±0.3% Full Scale typ. at 25°C ±1.0% Full Scale typ. (-10°C to 70°C) ±0.2% Full Scale typ. Best Straight Line (BSL) at 25°C 0.04% Full Scale/°F (0.02% Full Scale/°C)
0.2% Full Scale typ. 1 year at 25°C 1 ms typ. (10%-90% nominal pressure) 100 ms 15 PSI (1.03 bar) 30 PSI (2.07 bar) 6 g (25 to 2000 Hz) 50 g / 8 ms AISI316L stainless steel housing, pressure connection; Ceramic, Al2O3 (96%) Sensor; FKM (FPM, Viton), EPDM (TPE) seals; PUR cable 1.57” (40 mm) EN/IEC 61000-6-3 / GL 2012, IV, Part 7 (Emission and Immunity) 12.6 oz (357 g)

For installation support, please contact:

Maretron

120 Intracoastal Pointe Dr.

Jupiter, FL 33477

Toll Free: +1 (866) 550-9100

Phone: +1 (602) 861-1707

E-mail: [email protected]

Web: http://www.maretron.com

Copyright© 2022 Carling Technologies Inc., now part of Littelfuse – All rights reserved

P/N: M003088 Rev. 2.3 11/22

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals