Wejoin Cb01vf-i Dc Variable Frequency Barrier Gate User Manual

CB01VF-I DC Variable Frequency Barrier Gate

Product Information

The product is version 1.0.2 which includes the addition of
RS485 Communication Protocol. The mechanism installation direction
has also been changed in 2022.08.

RS485 Communication Protocol

The product uses RS485 Communication Protocol for communication.
With the auto-reversing on obstacle function, the boom will
automatically reverse when it encounters an obstacle during the
closing process. A non-concrete ground requires a cast-in-place
foundation.

Technical Data

The communication interface is located at position 15 and 10.
The boom opens to the up limit position and closes to the down
limit position. The angle is 0 degrees when the boom opens to the
up limit position and 90 degrees when it closes to the down limit
position.

Product Usage Instructions

  1. Ensure that the product is installed on a non-concrete ground
    with a cast-in-place foundation.
  2. Connect the communication interface located at position 15 and
    10 using RS485 Communication Protocol.
  3. Activate the auto-reversing on obstacle function to ensure that
    the boom automatically reverses when it encounters an obstacle
    during the closing process.
  4. When opening the boom, ensure that it opens to the up limit
    position which is at 0 degrees angle.
  5. When closing the boom, ensure that it closes to the down limit
    position which is at 90 degrees angle.

V1.0.2

Explanation

V1.0.2

Adding “RS485 Communication Protocol”

2022.08

3.4. Mechanism Installation Direction Change

Appendix

I. RS485 Communication Protocol

18

1.1.2. With auto-reversing on obstacle function, the boom will auto reverse when it meets obstacle during the closing process.

1.2. Technical Data
1.2.1. Working temperature (motor): -30~ + 70 1.2.2. Power supply input voltage: AC110±10%, or AC220V±10% 1.2.3. Controller input voltage: DC24V±10%, 10A 1.2.4. Motor power: 240W MAX 1.2.5. Relative Humidity: 30%~80%, No condensation 1.2.6. Distance of remote control: L30M 1.2.7. Running Speed: 2~6 seconds adjustable 1.2.8. MTBF: 6,000,000 times

non-concrete ground, cast-in-place foundation is needed.

and for

3

Communication Interface

15 10

opens to up limit position opens to up limit position opens to up limit position opens to up limit position opens to up limit position
angle is 0 degree when the boom opens to up limit position and 90 degrees when the boom closes to down limit position.