Innovaspa X251161 Drain Valve User Guide

X251161 Drain Valve

Product Information

  • Product Name: Draining Valve Replacement Kit
  • Model Number: N/A
  • Manufacturer: N/A
  • Part Number: 300-0233
  • Glue Brand: PVC 747 Weld-ON Glue
  • Glue Sizes:
    • 118 ml (Part #112-W12725WEL)
    • 237 ml (Part #105-0508)
  • Cutter Type:
    • Utility Knife (Box Cutter) (Part #137-HD-PVC-CUTTER2CE)
    • Pipe Cutter (Part #137-HOSECUTTERSCEN)

Product Usage Instructions

  1. Empty the spa of its water.
  2. Locate the draining valve by following these steps:
    1. Open the panel under the keypad.
    2. Open the Thermofoil and find the drainage hose (identified with
      a green sticker).
    3. Pull out the drainage hose from the spa.
  3. Connect the adapter to the draining valve by applying glue to
    both surfaces. Please note:
    • The adapter has two different diameters. The larger one
      connects to the draining valve, and the smaller one connects to the
      drainage hose.
  4. Using the cutter, cut the drainage hose near the draining
    valve. Ensure that the drainage hose is free of water.
  5. Attach the drain assembly to the drainage hose using glue.
  6. Allow 24 hours for the glue to dry before filling the spa. The
    glue bonds at temperatures of 15 degrees Celsius and above.
  7. Close the Thermofoil tightly with adhesive tape.

If you have any questions, please contact our service department
by phone at 1-866-995-8646, extension 226 or 227.

SERVICE CALL
DRAINING VALVE REPLACEMENT
JUNE 2022
YOU WILL NEED:

1 drain assembly
(Part # 300-0233)

PVC 747 Weld-ON Glue
(118 ml #112-W12725WEL or 237 ml #105-0508)

1 utility knife (box cutter) or pipe cutter
(Part # 137-HD-PVC-CUTTER2CE or 137-HOSECUTTERSCEN)

FIRST STEP
1- Empty the spa of its water. 2- Find the draining valve.
a) Open the panel under the keypad

b) Open the Thermofoil and find the drainage hose (identified with a green sticker)

c) Pull out the drainage hose from the spa

Having any questions? You may contact or service department by phone
1 866 995-8646, ext. 226 or 227

SERVICE CALL
DRAINING VALVE REPLACEMENT
JUNE 2022
SECOND STEP (REPAIR)
1- Connect the adapter to the draining valve by applying glue to both surfaces.
a) NOTE: The adapter has two different diameters. The larger one connects to the draining valve and the smaller one to the drainage hose.

2- With the cutter, cut the drainage
hose near the draining valve.
a) Make sure the drainage hose is free of water

3- Attach the assembly to
the drainage hose with glue

4- Allow 24 hours to dry before filling the spa. The glue bonds at temperatures of 15 degrees and above. 5- Close the Thermofoil tightly with adhesive tape
Having any questions? You may contact or service department by phone
1 866 995-8646, ext. 226 or 227