National Instruments Pxi-1408 Ni Imaq Video Frame Grabber Card Instruction Manual

PXI-1408 NI IMAQ Video Frame Grabber Card

Product Information

Product NamePXI-1408
ManufacturerNational Instruments
Board Assembly Part Number(s)184460E-01
Volatile Memory
TypeRAM
Size256 x 8
User AccessibleYes
System AccessibleNo
Battery Backup?No
Non-Volatile Memory
TypeEEPROM
Size64 K
User AccessibleNo
System AccessibleYes
Battery Backup?No
Media Storage
TypeNONE
Size
User Accessible
System Accessible
Battery Backup?

Product Usage Instructions

To use the PXI-1408 product, please follow these
instructions:

  1. Ensure that the product is properly installed in the PC or
    chassis.
  2. Connect any necessary cables or accessories to the
    product.
  3. Power on the PC or chassis.
  4. Follow the specific instructions provided by the software or
    application you are using in conjunction with the PXI-1408.
  5. If you need to clear the volatile memory (RAM), cycle power to
    the device by completely removing power from the PC or chassis.
    This includes shutting down the PC and/or chassis. A simple reboot
    is not sufficient.
  6. The non-volatile memory (EEPROM) does not require user access
    or clearing under normal operation.
  7. If you have any questions or need further assistance, please
    contact National Instruments support at 866-275-6964 or via email
    at [email protected].

PXI-1408

Letter of Volatility Under Normal Use Conditions NI PXI-1408

Board Assembly Part Number(s)

Part Number

Description

184460E-01

IMAQ PXI-1408

Manufacturer: National Instruments

Volatile Memory

Type1

Size

User Accessible/ System Accessible2

RAM RAM

256 x 8 1K x 9

Yes/Yes No/Yes

Battery Backup?
No No

Purpose
Lookup Table Video Data Buffer

Method of Clearing3
Power Down Power Down

Non-Volatile Memory

Type

Size

EEPROM

64 K

User Accessible/ System Accessible
No/Yes

Battery Backup?
No

Media Storage

Type

Size

NONE

User Accessible/ System Accessible

Battery Backup?

Purpose
Serial No., Calibration Configuration Data

Method of Clearing None available to user

Purpose

Method of Clearing

1 Calibration constants that are stored in device EEPROMs include information for the device’s full operating range. Calibration constants do not maintain any unique data for specific configurations at which the device is used unless otherwise specified.
2 Items are designated No for the following reason(s): a) Hardware changes or a unique software tool from National Instruments are required to modify contents of the memory listed. b) Hardware-modifying software tools are not distributed to customers for any personal access or customization, also known as non-normal use.
3 The designation None Available to User indicates that the ability to clear this memory is not available to the user under normal operation. The utilities required to clear the memory are not distributed by National Instruments to customers for normal use.

EDITION DATE August 2015 NI PART NUMBER 375574A-01

Contact: 866-275-6964 [email protected]

Letter of Volatility Under Normal Use Conditions NI PXI-1408
Terms and Definitions
User Accessible Allows the user to directly write or modify the contents of the memory during normal instrument operation.
System Accessible Does not allow the user to access or modify the memory during normal instrument operation. However, system accessible memory may be accessed or modified by background processes. This can be something that is not deliberate by the user and can be a background driver implementation, such as storing application information in RAM to increase speed of use.
Cycle Power The process of completely removing power from the device and its components. This process includes a complete shutdown of the PC and/or chassis containing the device; a reboot is not sufficient for the completion of this process.
Volatile Memory Requires power to maintain the stored information. When power is removed from this memory, its contents are lost.
Non-Volatile Retains its contents when power is removed. This type of memory typically contains calibration or chip configuration information, such as power up states.

EDITION DATE August 2015 NI PART NUMBER 375574A-01

Contact: 866-275-6964 [email protected]

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals