Samsung 7170-0977 Series Outdoor Flat Tilt Wall Mount Installation Guide

7170-0977 Series Outdoor Flat Tilt Wall Mount

Product Information:

Product Name: Outdoor Flat/Tilt Wall Mount For Samsung OH55

Model Number: 7170-0977 Series

Installation Guide: INST-1095 v1.0 Publ. May 2022

Wall Mount Model: 7170-0977-00 (flat), 7170-0977-01 (tilt)

Display Model: Samsung OH55

Installation Configuration: Landscape, Portrait

Tilt Feature: Fixed at flat, 5 deg, 10 deg, 15 deg

Environment Temperature: -30 Celsius to 50 Celsius, 24/7
operation

Wall Application: Solid concrete, Hollow Brick, or 3/4
plywood-backed wall

Product Weight: 31.5 lbs [14.4 kg] for flat model, 45.5 lbs
[20.6 kg] for tilt model

OA Weight (Mount & Flat-Panel): 147.5 lbs [66.9 kg] (flat),
161.5 lbs [73.26 kg] (tilt)

OA Width x Depth x Height (Portrait): 28.8 x (5.55 flat to 17.33
tilt) x 50.87

OA Width x Depth x Height (Landscape): 49.63 x (5.55 flat to
14.62 tilt) x 30.38

Product Usage Instructions:

Installation Environment:

  • Must not be placed in areas where seawater is accessible
    (Beach)
  • Must not be placed in areas with strong winds caused by storms
    or other natural phenomena (Wind)
  • Awning or cover is needed to avoid snow piling directly onto
    inlet (Snow)
  • Suitable for enclosed areas like train or subway stations (Iron
    Dust)

Enclosed or Recess Area:

Prohibited in any enclosed area. Must have a minimum clearance
of 52mm (2.05) all around and no additional front glass
allowed.

Core Components:

  • Mounting Frame x2
  • Hooking Bracket x2
  • Wall Plate x1
  • Partition / Baffle x2

Tilt Adapter (Option):

  • Tilt Coupling Bracket x4
  • Tilt Adapter x2
  • Tilt Brace x2

Hardware:

  • 1/4-20 x 2-1/2 Button Head x12
  • 1/4 Flat Washer x12
  • 1/4-20 x 5 Pan Head x4
  • 1/4-20 x 3/4 Button Head x8
  • 1/4 Flat Washer x8
  • 5/16 x 3 Hex Lag x6
  • 5/16 Split Lock Washer x6
  • 5/16 Flat Washer x10
  • Shell Expansion Anchor x6
  • M8 x 16mm Hex Bolt x4
  • Lock-it Security Barrel x1

Installation Steps:

  1. Mount the two mounting frames using the provided hardware.
    Torque the screws to 12 to 15 kgf/cm or 67 to 84 lbf/in.
  2. Attach the baffles/partitions using the provided screws and
    washers.
  3. Install the flat or tilt brackets based on your desired
    configuration (landscape or portrait) using the provided screws and
    washers. If applicable, mount the tilt coupling bracket in the
    designated hole.
  4. If mounting on solid concrete or brick, use the proper mounting
    guidelines per state code. If mounting on brick, ensure the proper
    hardware is used (not supplied). For wood applications, use a stud
    finder to locate wall studs and mark the wall. Drywood walls must
    be backed with at least 3/4 plywood to support the weight of the
    mount and flat-panel.
  5. For concrete/brick installations, use shell expansion anchors
    to secure the mount. Follow the recommended number and placement of
    mounting screws.

Note: The provided hardware and threaded rod are shown for
reference only and may not be supplied with the product.

7170-0977 Series
Installation Guide
Outdoor Flat/Tilt Wall Mount For Samsung OH55
INST-1095 v1.0 Publ. May 2022

7170-0977 Series
Installation Guide BASIC INFORMATION
Wall mount model Display Model Installation Configuration Tilt feature Environment Temperature Wall application Product Weight OA Weight (Mount & Flat-Panel) OA Width x Depth x Height (Portrait) OA Width x Depth x Height (Landscape)

7170-0977-00 (flat) 7170-0977-01 (Tilt)
OH55
Landscape Portrait
Available by model Fixed at flat, 5 deg, 10 deg , 15 deg
Negative 30 Celsius to 50 Celsius, 24/7 operation
Solid concrete, Hollow Brick, or 3/4″ plywood-backed wall
31.5 lbs [14.4 kg] for flat model 45.5 lbs [20.6 kg] for tilt model
147.5 lbs [66.9 kg] (flat) 161.5 lbs [73.26 kg] (Tilt)
28.8″ x (5.55″ flat to 17.33″ tilt) x 50.87″
49.63″ x (5.55″ flat to 14.62″ tilt) x 30.38″

INSTALLATION ENVIRONMENT

Beach Wind Snow Iron Dust

Must not be placed in areas where seawater is accessible Must not be placed in areas with strong winds caused by storms or other
natural phenomenon Awning or cover is needed to avoid snow piling directly onto inlet
Suitable, (e.g. train or subway station)

ENCLOSED OR RECESS AREA Clearance Additional front glass

52mm (2.05″) minimum all around Prohibited in any enclosed area

Page 2

CORE COMPONENTS:

Mounting Frame x2

Hooking Bracket x2

Wall Plate x1

7170-0977 Series
Installation Guide
Partition / Baffle x2

TILT ADAPTER (OPTION):

Tilt Coupling Bracket x4
Tilt Adapter x2

Tilt Brace x2

x12
1/4-20″ x 2-1/2″ Button Head

x12
1/4″ Flat Washer

HARDWARE:

x4
1/4-20 x 5″ Pan Head

x8
1/4-20″ x 3/4″ Button Head

x8
1/4″ Flat Washer

x6
5/16″ x 3″ Hex Lag

x6
5/16″ Split Lock Washer

x10
5/16″ Flat Washer

x6
Shell Expansion Anchor

x4
M8 x 16mm Hex Bolt

x1
Lock-it Security Barrel

Page 3

7170-0977 Series
Installation Guide
1

Mounting frame x2

Torque:
12 to 15 kgf/cm 67 to 84 lbf/in
4 Places

M8 x 16mm 5/16″ Split 5/16″ Flat Hex Bolt Lock Washer Washer

2
Baffle / partition

1/4-20″ x 3/4″ BH

1/4″ Flat Washer

x4

Page 4

Baffle / partition

Install flat or tilt brackets, landscape or portrait.

3

1/4-20″ x

1/4″ Flat

x4 3/4″ BH

x4 Washer

Flat – Figure A
Security Barrel

7170-0977 Series
Installation Guide
1/4-20 x 5″ Pan Head x4
If applicable, tilt coupling bracket mounting hole.

Mounts to brackets shown in figure c.

Tilt – Figure B
All hardware shown are 1/4-20″ x 3/4″ BH screw w/ washer.

5 Deg

10 Deg

15 Deg

Above

Figure C
UP This side down

Below

Mounts to brackets shown in figure c.

5 Deg

10 Deg

15 Deg

Page 5

7170-0977 Series
Installation Guide
Solid Concrete/Brick
Use proper mounting guideline per state code.

Brick (Alternative)
All hardware, threaded rod, epoxy, and other mounting hardware are not supplied. Shown for reference only.

Wood Application
Use a stud finder to determine the center of the wall studs in the vicinity of the mount and mark the wall. Drywood wall must be backed with at least 3/4″ plywall to support the weight of the mount and flat-panel.
Page 6

CONCRETE/BRICK
4
(OPEN)

7170-0977 Series
Installation Guide
3/4″ PLYWOOD-BACKED
(OPEN)

Requires a minimum of 4 mounting screws on upper slots and 2 on bottom slots. Shell expansion anchors are suitable for both concrete and brick.

Requires at least 4 mounting screws into wood stud and 4 mounting screws on the upper slots. Shell expansion anchors are not used for this application.

5
B

Depth varies by angle

MOUNTING DIMENSIONS

Viewing Height

3.91″ [99.3mm] (mounting slot)

A

E

D

C

Letter
A B C D E

Description
Net Height Tilt offset (Top) Tilt offset (Bottom) Bottom to mounting slot of the wall plate Mimimum clearance of recess area

1.97″ [50mm] mininum gap for ventilation

Portrait
50.87″ [1292.1mm] 2.50″ [63.5mm] 1.24″ [31.5mm] 22.30″ [22.3mm] 54.85″ [1393.2mm]

Landscape
30.38″ [771.7mm] 2.14″ [54.4mm] 1.59″ [40.4mm] 12.33″ [313.2mm] 34.36″ [872.8mm]

Page 7

7170-0977 Series
Installation Guide

6

Cover / Roof (Optional)

50mm mininum gap
for ventilation all around

UP arrow

Route cables through holes on the bracket.

(2) 1/4-20 x 5″ Pan Head

7

(Post-leveling Screws)

Shown: Portrait at 5 deg tilt

SECURITY FEATURE

8

Cable & lock

Padlock

Page 8

(2) 1/4-20 x 5″ Pan Head (Locking Screws)

Lock the security barrel to prevent the mount from being tampered or disengaged.

5.55″ [141mm)

8.61″ [218.7mm]

11.67″ [296.4mm]

7170-0977 Series
Installation Guide
14.62″ [371.4mm]

28.95″ [735.3mm] 28.64″ [727.5mm] 28.83″ [732.3mm] 28.80″ [731.5mm]

Flat

5 Deg

Portrait

5.55″ [141mm]

9.53″ [242.1mm]

10 Deg

Landscape

15 Deg

13.50″ [342.9mm]

17.33″ [440.2mm]

48.37″ [1254.0mm] 49.16″ [1248.7mm] 49.58″ [1259.4mm] 49.63″ [1260.6mm]

Flat

5 Deg

10 Deg

15 Deg Page 9

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals