Pce-sc 10 Sound Level Meter Calibrator User Manual

PCE-SC 10 Sound Level Meter Calibrator

Product Information

The PCE-SC 10 is a class 1 acoustic calibrator used for the
calibration of microphones, sound pressure level (SPL) meters, and
other noise meters. It is suitable for use with type 1 or class I
noise measuring instruments. This portable decibel (db) meter
calibrator is easy to use in the field or in laboratories.

Features

  • Quick and direct calibration of sound level meters and other
    sound measuring systems
  • Fits 1/2 microphones and 1/4 microphones (with adaptors)
  • Calibration frequency of 1000 Hz, the reference frequency for
    standardized international weighting networks
  • Automatic switch-off when the calibrator is removed from the
    microphone cavity to extend battery life

Applications

  • Calibration of microphones, sound level meters, and other sound
    measurement equipment
  • Check the linearity of the equipment to be calibrated

Technical Specifications

  • Frequency: Not specified
  • Sound pressure levels: Not specified
  • Accuracy: Not specified
  • Sound distortion: Not specified
  • Stabilization time: Not specified
  • Microphone aperture: Not specified
  • Operating conditions: Not specified
  • Power supply: Not specified
  • Dimensions: Not specified
  • Weight: Not specified

Product Usage Instructions

  1. Pull down the battery compartment cover and insert the
    batteries, ensuring correct polarity.
  2. Switch on the calibrator and the device to be calibrated using
    the On/Off key.
  3. Set the desired sound pressure level (either 94 or 114 dB)
    using the change key.
  4. Place the aperture of the calibrator on the microphone, using
    an adaptor if necessary.
  5. A value will appear in the display of the sound level meter.
    Wait for this value to stabilize.
  6. Turn the calibration screw to adjust the value according to the
    desired calibration.

Englis h

User Manual
Sound Level Meter Calibrator PCE-SC 10
User manuals in various languages (français, italiano, español, português, nederlands, türk, polski,
, ) can be found by using our product search on: www.pce-instruments.com
Last change: 8 February 2018 v1.0
© PCE Instruments

Contents 1 Safety notes ………………………………………………………………………………. 1 2 Introduction ………………………………………………………………………………. 2 3 Applications………………………………………………………………………………. 2 4 Features ……………………………………………………………………………………. 2 5 Functional block diagram ………………………………………………………….. 2 6 Information on calibration principle……………………………………………. 3 7 Operation ………………………………………………………………………………….. 3 8 Technical specifications ……………………………………………………………. 3 9 Delivery contents ………………………………………………………………………. 3 10 Contact……………………………………………………………………………………. 4 11 Disposal ……………………………………………………………………………………. 4
© PCE Instruments

1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
· The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
· The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
· Do not expose the device to shocks or strong vibrations. · The case should only be opened by qualified PCE Instruments personnel. · Never use the instrument when your hands are wet. · You must not make any technical changes to the device. · The appliance should only be cleaned with a damp cloth. Use only pH-neutral
cleaner, no abrasives or solvents. · The device must only be used with accessories from PCE Instruments or equivalent. · Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device. · Do not use the instrument in explosive atmospheres. · The measurement range as stated in the specifications must not be exceeded under
any circumstances. · Non-observance of the safety notes can cause damage to the device and injuries to
the user. We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.
© PCE Instruments 1

2 Introduction
The PCE-SC 10 is a class 1 acoustic calibrator used for the calibration of microphones, sound pressure level (SPL) meters and other noise meters. The sound calibrator is suitable for use with type 1 or class I noise measuring instruments. This portable decibel (db) meter calibrator is easy to use in the field or in laboratories.
3 Applications
– Calibration of microphones, sound level meters and other sound measurement equipment – Check the linearity of the equipment to be calibrated
4 Features
– Complies with IEC60942:2003 Class 1, ANSI S1.40-1984 and GB/T 15173-1994 – 1 kHz calibration frequency for all weighting networks – Dual 94 & 114 dB sound pressure level outputs – Calibration accuracy ± 0.3 dB – Highly stable level and frequency – Easy 2-key operation – Fits 1/2″ microphones and 1/4″ microphones (with adaptor) – Powered by 2×AA batteries and automatic power off to conserve battery life
5 Functional block diagram
© PCE Instruments 2

6 Information on calibration principle
The PCE-SC 10 sound calibrator is a battery operated sound source for quick and direct calibration of sound level meters and other sound measuring systems. It fits 1/2″ microphones and 1/4″ microphones (with adaptors). The calibration frequency is 1000 Hz, which is the reference frequency for the standardized international weighting networks. That enables you to
use the calibrator for calibrating sound equipment with A, B, C, D weighting filters and linear. The calibration pressure is 94 ±0.3 dB (1 Pa) and 114 ±0.3 dB (10 Pa). The PCE-SC 10 is equipped with a feed-back arrangement to ensure a highly stable sound pressure level. The feed-back loop contains a reference microphone, a sound source and control circuit. The reference microphone has passed a long-term aging test and has proved to be extremely stable. The feed-back control circuit can adjust for changes in load volume, temperature, humidity and atmospheric pressure. The calibrator gives a continuous sound pressure level
when fitted onto a microphone and detects when the microphone is removed from the cavity and automatically switched off, thereby extending the battery life. When the ON/OFF light
flashes, this means that the battery voltage is low. If the device stops working continuously, the
batteries must be replaced.

7 Operation
– Pull down the battery compartment cover and insert the batteries. Make sure the polarity is correct.
– Switch on the calibrator as well as the device to be calibrated (On / off key). Set either 94 or 114 dB, using the change key.
– Place the aperture of the calibrator on the microphone (use the adaptor if applicable). – A value now appears in the display of the sound level meter. When this value has stabilised,
turn the calibration screw to adjust the value accordingly.

8 Technical specifications
Frequency Sound pressure levels Accuracy Sound distortion Stabilization time Microphone aperture Operating conditions
Power supply Dimensions Weight

1 kHz / ±0.5 % 94 dB and 114 dB ±0.3 dB <2 % <10 s 1/2″ and 1/4″ according to IEC 61094-4 -10 … +50 °C (+10 … +122 °F) 10 … 90 % RH 2 x 1.5 V AA batteries (LR6) 75 x 70 x 46 mm (2.96 x 2.76 x 1.82″) 316 g (0.7 lb)

9 Delivery contents
1 x sound calibrator PCE-SC 10 2 x 1.5 V AA battery (LR6) 1 x adaptor

© PCE Instruments 3

10 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
11 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.
© PCE Instruments 4

PCE Instruments contact information

Germany
PCE Deutschland GmbH Im Langel 4 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 [email protected] www.pce-instruments.com/deutsch

France
PCE Instruments France EURL 23, rue de Strasbourg 67250 SOULTZ-SOUS-FORETS France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 [email protected] www.pce-instruments.com/french

United States of America
PCE Americas Inc. 711 Commerce Way suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 [email protected] www.pce-instruments.com/us

United Kingdom
PCE Instruments UK Ltd Units 12/13 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 [email protected] www.pce-instruments.com/english

The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 Fax: +31 53 430 36 46 [email protected] www.pce-instruments.com/dutch

Chile
PCE Instruments Chile S.A. RUT: 76.154.057-2 Santos Dumont 738, local 4 Comuna de Recoleta, Santiago, Chile Tel. : +56 2 24053238 Fax: +56 2 2873 3777 [email protected] www.pce-instruments.com/chile

China
PCE (Beijing) Technology Co.,Ltd 1519 Room, 6 Building Men Tou Gou Xin Cheng, Men Tou Gou District 102300 Beijing China Tel: +86 (10) 8893 9660 [email protected] www.pce-instruments.cn

Turkey
PCE Teknik Cihazlari Ltd.ti. Halkali Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece – stanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 [email protected] www.pce-instruments.com/turkish

Spain
PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 [email protected] www.pce-instruments.com/espanol
Italy
PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 LOC. GRAGNANO CAPANNORI (LUCCA) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 [email protected] www.pce-instruments.com/italiano
Hong Kong
PCE Instruments HK Ltd. Unit J, 21/F., COS Centre 56 Tsun Yip Street Kwun Tong Kowloon, Hong Kong Tel: +852-301-84912 [email protected] www.pce-instruments.cn

© PCE Instruments 5

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals