Hybrid Inverter with Controller
Product Information
- Product Name: Inverter Charger System Hybrid Inverter with
Controller - Catalog: Available
Installation Notice
Refer to page 2 of the user manual for installation
instructions.
Product Key Features/Introduction to Working Principle
Refer to page 4 of the user manual for detailed information on
the product’s key features and working principle.
Introduction to Working Mode
Refer to page 5 of the user manual for detailed information on
the product’s working modes.
Outward Appearance
Refer to page 6 of the user manual for a visual representation
of the product’s outward appearance.
Inverter Charger Back Panel
Refer to page 6 of the user manual for a description and diagram
of the inverter charger back panel.
Hybrid Inverter with Solar Controller Back Panel
Refer to page 7 of the user manual for a description and diagram
of the hybrid inverter with solar controller back panel.
DC Wiring
Refer to page 8 of the user manual for detailed information on
DC wiring.
12V Connection Diagram
Refer to page 9 of the user manual for a connection diagram for
12V setup.
24V Connection Diagram
Refer to page 9 of the user manual for a connection diagram for
24V setup.
AC Wiring
Refer to page 10 of the user manual for detailed information on
AC wiring.
Automatic Transfer Relay
Refer to page 10 of the user manual for information on the
automatic transfer relay feature.
Dry Contacts for Auto Generator Start
Refer to page 10 of the user manual for information on the dry
contacts for auto generator start feature.
Auto Restart Temperature Fault
Refer to page 10 of the user manual for information on the auto
restart temperature fault feature.
FAN Operation
Refer to page 11 of the user manual for information on the
operation of the product’s fan.
Inverter Connection Diagram
Refer to page 12 of the user manual for a connection diagram for
inverter setup.
Hybrid Inverter with Solar Controller Connection Diagram
Refer to page 12 of the user manual for a connection diagram for
hybrid inverter with solar controller setup.
Solar Panel and Battery Connection Diagram
Refer to page 13 of the user manual for a connection diagram for
solar panel and battery setup.
LED Indicator and LCD Introduction
Refer to page 14 of the user manual for information on the LED
indicator and LCD display.
LCD Information
Refer to page 16 of the user manual for information on the LCD
display.
Parameter Setting
Refer to page 17 of the user manual for instructions on how to
set parameters for the product.
INVERTER CHARGER SYSTEM HYBRID INVERTER WIHTCONTROLLER
Catalog
Installation notice …………………………………………………………………………………………………………………………….2
Product Key Features/ Introduction to working principle……………………………………………………………………….. 4
Introduction to working mode ……………………………………………………………………………………………………………. 5
Outward appearance…………………………………………………………………………………………………………………………6
inverter charger back panel ……………………………………………………………………………………………………………….. 6
Hybrid inverter with solar controller back panel …………………………………………………………………………………… 7
DC wiring……………………………………………………………………………………………………………………………………………. 8
12V connection diagram ……………………………………………………………………………………………………………………. 9
24V connection diagram ……………………………………………………………………………………………………………………. 9 AC wiring………………………………………………………………………………………………………………………………………….. 10
Automatic Transfer Relay ……………………………………………………………………………………………………………….. 10
Dry Contacts for Auto Generator Start ………………………………………………………………………………………………. 10
Auto Restart Temperature Fault ………………………………………………………………………………………………………. 10
FAN Operation…………………………………………………………………………………………………………………………………… 11
Inverter connection diagram…………………………………………………………………………………………………………………. 12 Hybrid inverter with solar controller connection diagram…………………………………………………………………………. 12 Solar panel and battery connection diagram……………………………………………………………………………………………. 13
LED indicator and LCD introduction…………………………………………………………………………………………………….. 14
LCD information ………………………………………………………………………………………………………………………………. 16
parameter setting ………………………………………………………………………………………………………………………………… 17
Fault code and repair …………………………………………………………………………………………………………………………… 22
buzzer alert ……………………………………………………………………………………………………………………………………. 23 Specifications …………………………………………………………………………………………………………………………………….. 24
1
Installation notice
Important Safety Instructions
Please save these instructions.
This manual contains important safety, installation, and operating instructions for the inverter ,please ad the product manual carefully before using this product.
Check the package is complete before opening. After opening packing please check the accessories, The accessories includes 1PCS user manual and check the inverter is still protected well after transportation
If you find damage or missing parts, please do not turn on the machine and contact your dealer.
Please keep the packing box and materials for can be for next delivery if need. This series of products is very heavy, please handle it carefully .
The inverter installation must be more than 30cm away from the wall, well ventilated, free of water, flammable gases and corrosives. As shown in the figure:
Not good placed in a corner, side, or upside down, away from heat sources. To avoid direct sunlight, ensure that the front panel, rear panel, and fan inlets have good ventilation.
The environment temperature should be between 0 °C and 40 °C. If the machine is disassembled and used in a low temperature environment, may happen
water condense ,only can work till through dry of machine inside and outside ,otherwise will be shock risk Please install the inverter near the mains input socket or switch. It is easy to unplug the mains input or cut off the power supply when meet emergency situation.. The external battery should not be exposed. It should be installed in the battery cabinet.. The DC input between inverter should be short as possible Do not stack goods on the inverter. When the load is connected to the inverter, the load must be turned off before wiring, and The inverter is connected to a socket with over current protection, and the machine is safely grounded. The power outlet should be safely grounded. If need to make the inverter no output, must turn off all switches first, then turn off the mains
2
power supply .Whether the inverter has input or not ,MUST turning off the inverter does not ensure that the internal parts are not have power. Need to touch inductive load: when inductive load such as motor, display, laser printer. The inverter capacity is three times of the load equipment starting power . Need often to keep charging to extend battery life. When the inverter is connected to the normal mains, whether inverter is on or off, it still keep charging the battery, and provides overcharge protection. Normally , the battery life is three to five years. If there is a problem with the battery, it must be replaced early. When replacing the battery, it must be operated by professionals. It is not recommended to replace the battery individually. When replacing, should follow the battery supplier’s operating instructions. note: Before replacing the battery, you must cut off all power connected to the machine: mains switch, battery switch, etc. Take off metal objects such as rings and watches. Use tool as handles and screwdrivers. Do not put tools or other metal objects on the battery. It is normal for a small spark when connecting the battery cable, but will not harm human safety and inverter. Note: Do not short the battery positive and negative, can’t connection reverse battery.
Inverter Safety
The inverters are suitable for Battery Banks ONLY. Always make sure inverter is in OFF position and disconnect all AC and DC connecting when working on any circuit associated with the inverter.NEVER connect the AC output of the unit directly to an Electrical Breaker Panel/ Load Centre which is also fed from the utility power / generator .When connecting battery terminals, ensure the polarity of the battery connections is correct. Incorrect polarity may cause permanent damage to the unit .Be careful when touching bare terminals of capacitors as they may retain high lethal voltages even after power is removed.
Battery Safety
Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Use sealed Lead-Acid, Flooded, Gel, AGM, Lithium batteries which must be deep cycle. Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases. Be careful when working with large lead acid batteries. Wear eye protection and have fresh water available in case there is contact with the battery acid. Over-charging and excessive gas precipitation may damage the battery plates and activate material shedding on them. Too high of an equalizing charge or too long of one may cause damage. Please carefully review the specific requirements of the battery used in the system. Installation Safety The unit should be installed in a well-ventilated, cool, and dry environment. Make sure the fans of the unit and the ventilation holes are not blocked. Do not expose the unit to rain, moisture, snow, or liquids of any type.
3
Product Key Features
Suitable for mains power unstable or often off, and important equipment that requires backup power.
This product adopts high-precision DSP control chip, precise detection circuitadvanced control technology .
Intelligent temperature-regulating fan, efficient heat dissipation, extending system life.
Pure sine wave output ,Multiple working mode options
Multiple electronic protections short circuit protection, overvoltage and under voltage protection, overload protectionOverheat / short circuit automatic restart(automatic restart three times)
wide frequency and wide voltage input, can be used for diesel / gasoline generator input.
3-Stage battery charger with configurable charging current
8 Pre-Set battery voltages including Lithium; User-defined option
Introduction to working mode
Work mode 01 Mains priority
02 Energy saving mode
03 Battery priority mode
Description
When the mains power is available, the mains power supply power to the load, and when the mains power is off, the battery will supply power to the load and charging to battery.
When the inverter is in battery priority mode and the output load is less than 1%-10% of the power( set by the P7 ,10% default), the AC output will be turn off, The inverter restarts every 1 minute, and checks whether the load is greater than the set power. When the connected load is greater than the minimum setting, the inverter restarts output. This function is to reduce the battery loss and extend the battery backup time. The battery supply power to the load. When the battery voltage is lower than the set battery voltage(voltage set by PA item), use mains power supply power to the load. When the battery voltage is restored , the battery will supply power to the load again (When battery power is low or PV power is off inverter use mains power charging for battery or not set by PC.
4
04 Mains priority unattended mode
05 Battery priority unattended mode
Inverter automatically turn on when connected to mains power or battery voltage is normal (not include inverter first time use) . But when the battery discharge voltage lower than battery voltage by set F4 (F4: set the battery low voltage power is turn off), the power will be turned off. Inverter on only mains power is coming or turn on by hand.( mains is charging is or not set by PC ) When the battery voltage is normal ,the inverter automatically turn on and battery supply power to the load. When the battery is low voltage ,mains power supply power to the load. When the battery discharge to battery low voltage shutdown (PL setting), the inverter enters standby and waits for the mains power or solar charging to battery .When the battery voltage is restored (PN setting),the inverter automatically turn on .But when the battery discharge voltage is lower than battery voltageset by F4), power will be turn off .Inverter on only mains power is coming or turn on by hand
Outward appearance
Front panel
UP ON/OFF LCD LINE ON INT/CHARGE FAULT
DOWN SET
5
inverter charger back panel
1-3KW
4-6KW
6
Hybrid inverter with solar controller back panel
1-3KW
4-6KW
7
DC wiring
WARNING DC wiring not following the minimum DC requirement will cause irreversible damage to the unit.
CAUTION Be careful of the positive and negative poles. Reversing the poles might cause permanent damage to the inverter. It will surely blow the internal fuse.
NOTE Damage to the inverters due to reverse polarity is NOT covered by warranty.
NOTE The input terminals of the inverters have large capacitors connected to them. Once a positive and negative wire are connected to the terminals, it will complete the circuit, and commence drawing a heavy current momentarily. As a result, there may be a sparking occurring even if the inverter is in the off position. To minimize sparking, it is recommended that the user have the appropriate size wire feeding into the inverters and/or install an external fuse leading into the inverter.
WARNING Ensure all sources of DC power (i.e., batteries, solar, etc.) and AC power (utility power or AC generator) are de-energized (i.e., breakers opened, fuses removed) before proceeding–to prevent accidental shock.
1. Unscrew the screw terminals along the edge of the side plate 2. Gently remove DC Side plate to expose DC Terminals 3. Connect the positive and negative DC Cables to their respective terminals and run them
through the side panel
WARNING
The Terminals must clean to reduce the resistance in the cable connection. A buildup of dirt or oxidation may eventually lead to the cable terminal overheating during periods of high current draw When installing DC cables, the following are recommendations: 1.Battery positive and negative cables should be as close to the battery as possible to minimize voltage loss and other possible effects. 2.Tie, tape, or twist cables together to reduce self-inductance. 3.Install all overcurrent devices on the positive cable.
8
12V connection diagram 24V connection diagram 48V connection diagram
9
AC wiring
CAUTION Avoid switching on the inverter with the load (electronic devices) already switched on. This may trigger an overload since some electronic devices have an initial high power surge to start.
CAUTION When switching off the inverter, turn off the electronic devices first. Although the inverter is off, the capacitors will still have a charge, so the DC and AC terminals must be disconnected if altering the circuitry.
CAUTION Ensure all sources of DC power (i.e., batteries, solar, etc) andAC power (utility power or AC generator) are de-energized (i.e., breakers opened, fuses removed) before proceeding–to prevent accidental shock.
Steps
1. Remove the AC Terminal block 2.Make note of the AC Input terminals from left to right (Neutral, Live, Ground). and the AC output terminals from left to right (Neutral, Live, Ground).
* If you want to connect the inverter to diesel generator or gasoline generator, please follow
these steps:
NL GNL G
AC INPUT
AC OUTPUT
1. Turn on the generator, after it works stably, connect generator output to the inverter input(Confirm the inverter is no-load), then turn on the inverter as normal. After the inverter starts working, connect the load.
2. Recommended generator capacity is 2-3 times larger than the inverter.
WARNING The AC input must NEVER be connected to the AC output as irreversible overload or damage may result AC Output should NEVER be connected to public power or a generator
WARNING This cannot be disabled.
10
Automatic Transfer Relay The inverter chargers are equipped with a 30A transfer relay switch that switches between Inverter and Standby mode depending on availability of AC input power. If AC is present, the transfer relay bypasses up to 30A of the incoming AC power through the inverter to power the AC loads on the inverter’s output. In the event AC power gets disconnected, the inverter will power the loads through the battery bank.
WARNING The inverter’s internal AC transfer relay contacts are rated for 30 amps (each leg), the pass-through current for relay contact must be no greater than 30 amps or damage to this relay may occur.
Dry Contacts for Auto Generator Start
To use this to function, an auto start controller must be installed on the generator. there are three contacts; left to right: Normally Closed (NC) Common (COM), Normally Open(NO).
When mains power is off ,inverter use battery power supply the load ,dry contact auto start Do not store units with auto gen start feature enabled. Generators exhaust dangerous fumes
when running.
Auto Restart Temperature Fault
The operating temperature range for the inverter series is 0C°-40C° / 32F° – 104F°. If internal power components begin to exceed their safe operating temperature level, the inverter shuts down to protect itself from damage. need to manually restart when the inverter cools down .
FAN Operation
By default, when first powering the unit the fans and alarm will run for approximately 1 minute as part of the start-up routine. Other fan ON/OFF operation parameters are listed below:
Condition Inverter Charger Uptime Inverter Mode Load Percentage DC Input Current Inverter Heat Sink Temperature
Turn on Condition Uptime 1 minute Load 35% Current 10A Temperature 50
Turn off Condition Uptime > 1 minute Load < 35% Current < 6A Temperature < 45
11
Inverter connection diagram
Hybrid inverter with solar controller connection diagram
Solar panel and battery connection diagram
Solar panels in series
Solar panel voltage = 1 + 2 + 3 + … n, the voltages of each solar panel are added together.
12
Batteries in series
Battery voltage = 1 + 2 + 3 + … n, the voltages of each battery are added together.
Solar panel in parallel
Solar panel voltage = 1 = 2 = 3 = … n, the voltage of 1PCS solar panel (the voltage of each panel must be the same to be connected in parallel).
Battery in parallel
Battery voltage = 1 = 2 = 3 = … n, the voltage of 1PCS battery (the voltage of each battery must be the same to be connected in parallel).
13
LED indicator and LCD introduction
LED indicator
Green Light Yellow Light
Red Light
In the mains working mode, the LED light is on when the mains is working, the green light off when the inverter is inverting.
1. Solid Battery is fully charged or inverter mode In the 03 battery priority mode, the PC menu determines the light is on or off during charging.
2. Flashing Battery is charging mains charging indicator. (It will off when charging is completed.
1. Flashing when the overload is more than 105%, lighting when the overload is more than 110%, lights flashing when the battery is low
2. Solid when the inverter fails.
Hold 3-5 seconds to turn on the inverter and buzzer will sound. Hold 3 seconds to turn off the inverter
Press UP or DOWN to check LCD display parameters
1.Press3-5 seconds to enter the inverter setting page parameter 2.Press to confirm setting in parameter setting
14
LCD inf
0%-25%
26%-50%
51%-75%
76%-100%
LCD information
Battery Information Battery voltage 14.00V 13.30V 13.00V 12.60V 12.40V 12.20V 12.00V 11.80V 11.60V 11.40V 11.20V 10.00V
Battery capacity percentage 100% 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%
15
No Inverter mode :No mains input, only connect to battery 03: Battery priority mode, mains status (mains icon will flash) LOAD***%: Load % display
Overload display (Over Load icon will flashes)
BATT **V: Battery voltage display
Hybrid solar input information
Solar input with mains
PV ***V Solar input voltage display
16
Mains
mode
(battery capacity
icon flashing when
AC charging
50Hz/60Hz Frequency display(Automatic)
LOAD ***W: Load power display
BATT***%: Battery % display
INV0.0KW: Inverter total output power display
Solar input without mains
PV ***A Solar input current display
parameter setting
Turn on inverter in the normal working
press the SET button for 5S ,P0 will flashing
Press UP or Dowm button to choose P1-F9 menu
press the SET button for 3S. Parameter will flashing
Turn Off inverter to save setting
press the SET button 3S to exit setting
Press UP or Down button to choose Parameter
1. When the inverter in the normal working 2. press the SET button for 5S to enter the setting menu. Enter the setting menu, LCD shows
the working mode icon is flashing. 3. Press the UP button or the DOWN button to operate the menu options. The working mode
icon will change depending on the operation. 4. When choose the right menu option, press the setting button SET 3S to enter the setting
parameters,(At this time, the working mode icon is not flashing, in the left parameter item is flashing.) 5. Press the up or down button to select the setting parameter, press the STE button 3S to exit the setting.(At this time, the working mode icon flashes, and the parameter icon does not flash.) 6. To exit the mode (ESC), press the SET button 3S to enter the set parameters and then press the SET button 3S to exit the setting menu and save the settings, 7. Need to press the ON/OFF button to save parameters Setting.
17
Parameter setting
Menu options
P0:Set work mode menu: Press the SET button 3S to enter the setting menu, the menu selection icon is flashing. If need save and exit, press the SET button 3S to save and exit
P1: work mode setting: 01: Mains priority mode 02: Energy saving mode 03: Battery priority mode 04: Mains priority Unattended mode 05: Battery priority Unattended mode
P2: Battery type and charging voltage setting: SLD: lead-acid battery (default), GEL: gel battery, LI: lithium battery, USE: user mode. Select USE user mode to adjust battery voltage in P3 and P4 menus. If you do not select the USE user mode, the P3 and P4 menus will not appear.
P3: Battery voltage uniform charge setting: 12.5V 15.5V (single) can be set
P4: Battery voltage floating charge setting: 12.5 13.9 (single) can be set
18
P5: Maximum mains charging current setting: (Default 300W:10A 500W-1500W:15A 2000W20A3000W-12000W:50A) 5A, 10A, 20A, 30A, 40A, 50A,
P6: Buzzer sound setting: ON: Turn on the buzzer, OFF: Turn off the buzzer (overvoltage, under voltage, overload, over temperature, except faults)
P7: Energy saving mode AC output setting: (10% default), in (USE) user mode can be adjusted up and down 1.0-10% / 1%
P8: Inverter output voltage setting: 220V default, (208V, 210V, 220V, 230V, 240V)
P9: AC Output frequency setting: 50Hz default, (50Hz, 60Hz)
PA: battery priority mode battery under voltage to mains voltage setting: 10.5V default, (single section: 10.5V, 10.6V, 10.7V, 10.8V, 10.9V, 11.0V, 11.1V, 11.2V, 11.3V, 11.5V)
19
PB: battery priority mode, when battery voltage is restored inverter from city power conversion inverter voltage: 13.2V default, (single battery: 13.2V, 13.3V, 13.4V, 13.5V, 13.7V, 13.9V, 14.1V, 14.4V)
PC: battery priority mode, mains is charged or not: AUOT default, ON (battery priority with AC charging), OFF (battery priority without AC charging), Automatic detection solar priority or city power priority, select solar charging, the mains will charge when the solar charging current is small) The specific charging method is as follows:
The relationship between solar charging and mains charging:
Mains charging current (* maximum set charging Solar charging current
current)
40A
0%
30A
20%
20A
40%
10A
60%
5A
80%
0
100%
Pd: AC input lowest voltage setting: Default 160VAC, (140V, 150V, 160V, 170V, 180V)
PE: AC input highest voltage setting: Default 135VAC(110VAC) 275VVAC(220VVAC) Rang: 110VC :130VAC-145VAC
220VAC: 260V-,290VVAC)
20
PF: AC input minimum frequency setting: Default 45Hz, (40Hz, 41Hz, 42Hz, 43Hz, 44Hz, 45Hz
PH: AC input maximum frequency setting: Default 63Hz, (63Hz, 64Hz, 65Hz)
PL: Battery low voltage shutdown setting: (must : Pn>PL>F4) 10.2V default,9.5V 12.0V (single) can be set
Pn: unattended mode, battery under voltage restores the startup voltage setting:(must : Pn>PL>F4) 12.4V default,11.0V 13.0V (single) can be set
F3: Generator mode setting: Default OFF (ON OFF)
F4: Unattended mode battery voltage low power off power point setting: (must : Pn>PL>F4) Default single section 10.0V (9.0V-12.0V can be set)
21
F5: Fan failure detection settings: Default single block OFF (ON, OFF)
F9: Negative temperature detection setting: The default OFF, (ON, OFF ) When the temperature is below -15 use the machine, please turn on this setting (ON)
Fault code and repair
This icon
will flash when there is a fault.
it will flash when there is a fault.
Fault code display
Cause E01 E02 E03 E04 E05 E06 E07
Buzzer or indicator
1 long 2 short B-BB shout, red light is off Buzzer urgent shouting, the red light lighting Intermittent ringing, red light is off Keep shouting, red light keep lighting Keep shouting, red light keep lighting Keep shouting, red light keep lighting
Fault cause Battery low voltage
Battery overvoltage
Battery low voltage
Transformer secondary line reverse connection Inverter startup failure
Output for short circuit Output voltage is too low or overloaded
Solution Check the battery is broken or not Check the battery is broken or not Check the battery is broken or not Restart or contact the supplier
Check output have short circuitoverload or not Check output have short circuitoverload or no Check output voltage and load
E08 Keep shouting, red light keep Temperature is too high Check the fan is working lighting
E09 Output Low voltage
22
E10
E11 Keep shouting, red light keep Low temperature or Check the temperature control
lighting
temperature control lines are not open circuit ,
failure
dropped
E12
E13
E14 Keep shouting, red light off Fan open circuit
Check the fan are not open
circuit , dropped
E15
Input relay short circuit Tap the input relay to check it
broken or not
ES0 Displayed when press the Controller work well Controller work well
controller display page
ES3 Displayed when press the Controller over current Internal fault
controller display page
ES4 Displayed when press the Controller temperature Internal fault
controller display page
high
ES5 Displayed when press the Solar input overvoltage Check Solar input voltage and
controller display page
correct number of solar panels
ES6 Displayed when press the Solar input low voltage Check Solar input voltage and
controller display page
solar panels not have damaged
buzzer alert
Buzzer sound: 1) Inverter: A beep sounds every 10 seconds. 10S — 10S –2) When the battery voltage is low, one sound per second. –1S–1S-3) When the battery is high voltage: three sound every four seconds, one long and two short. 4S
4) Overload: > 110% long sound. —> 105% sound every two seconds. 2S — 2S –5) Temperature control failure: 2 sound every 4 seconds 4S– –4S–6) The temperature is too high: sound every two seconds. 2 — 2 –7) Fan abnormality: long sound —
23
110VAC 120VAC Inverter With Charger Technical Specifications
Model
Inverter Specifications
1000W
1500W
2000W
3000W
4000W
5000W
6000W
Surge Power (1 second)
3000W
4500W
6000W
9000W
12000W
15000W
18000W
Surge Power (10 seconds)
1300W
1950W
2600W
3900W
5200W
6500W
7800W
Surge Power (60seconds)
1100W
1650W
2200W
3300W
4400W
5500W
6600W
Commercial Power Range
110VAC:83V-137VAC 120VAC:90V-150V
AC Frequency Range AVR Voltage RangeVAC
45-65HZ 110VAC/120VAC±10% Auto-sensing
110VAC:83V-137VAC 120VAC:90V-150V
Output Frequency Range(AC mode)
Tracking automatically /shared frequency with the commercial inversion state:60/50±0.5 Hz
DC Voltage Input Input Wave Form
12 VDC /24VDC
24VDC /48VDC Sine Wave ( Utility or Generator )
48VDC
Output Wave Form
Pure Sine Wave
Output Overload
Thermal Method Communication port
temperature Humidity
105% < Load < 110% ± 10% : Fault ( Turn off output after 60 seconds) 110% < Load < 130% ± 10% : Fault ( Turn off output after10 seconds)
150% < Load ± 10% : Fault ( Turn off output after 1 seconds) Cooling fan in intelligent control42 fan rotates slowly to 45 fan rotates fast
RS232/WIFI/SNMP(Optional) -15+50 10%90%
Short Circuit Protection
Software Protection
Line Mode Efficiency
>
Optimal Efficiency
95% >85%
Battery Type Input Voltage Range Floating Charge Set Low Voltage Restored Low Voltage Shutdown set Over Voltage Protection Over Voltage Alarm
AC Charging Transfer Time
Waveform
DC Battery Specifications
GEL, AGM, SLA, FLD, LI, USER 12VDC:10.5-15VDC 24VDC:21-30VDC 48VDC:42-60VDC
12.9 13.6 V(1PCS battery) can be set
12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC
12VDC:10-10.9V
24VDC:20-21.8V 48VDC:40-43.6V
12VDC:16.7VDC 24VDC:33.4V 48VDC:66.8V
12VDC:15VDC 24VDC:30V 48VDC:60V
5A-35A(40A, 50A, 60A,70A Optional Typical5-8ms(Including detection time)
Pure sine wave
1
Model External Size(mm)
L*W*H Gross Size(mm)
L*W*H Net Weight(kg)
Gross Weight(kg)
General Specifications
1000W
1500W
2000W
3000W
510*325*215mm
560*380*280mm
14
15
18
20
16
17
20
23
4000W
5000W
6000W
645*325*215mm
730*400*290mm
30
32
35
33
35
38
110VAC 120VAC Hybrid Inverter With Controller Technical
Model
Inverter Specifications
1000W
1500W
2000W
3000W
4000W
5000W
6000W
Surge Power (1 second)
3000W
4500W
6000W
9000W
12000W
15000W
18000W
Surge Power (10 seconds)
1300W
1950W
2600W
3900W
5200W
6500W
7800W
Surge Power (60seconds)
1100W
1650W
2200W
3300W
4400W
5500W
6600W
Commercial Power Range
110VAC:83V-137VAC 120VAC:90V-150V
AC Frequency Range AVR Voltage RangeVAC Output Frequency Range(AC mode)
45-65HZ 110VAC/120VAC±10% Auto-sensing
110VAC:83V-137VAC 120VAC:90V-150V
Tracking automatically /shared frequency with the commercial inversion state:60/50±0.5 Hz
DC Voltage Input Input Wave Form
12 VDC /24VDC
24VDC/48VDC Sine Wave ( Utility or Generator )
48VDC
Output Wave Form
Pure Sine Wave
Output Overload
Thermal Method Communication port
temperature Humidity
105% < Load < 110% ± 10% : Fault ( Turn off output after 60 seconds) 110% < Load < 130% ± 10% : Fault ( Turn off output after10 seconds)
150% < Load ± 10% : Fault ( Turn off output after 1 seconds) Cooling fan in intelligent control42 fan rotates slowly to 45 fan rotates fast
RS232/WIFI/SNMP(Optional) -15+50 10%90%
Short Circuit Protection
Software Protection
Line Mode Efficiency
>
Optimal Efficiency
95% >85%
2
Model MAX Solar Charger Current
Battery DC Voltage PV Voltage Input Range MAX PV Power Input
MPPT solar charge controller
1000W
1500W
2000W
3000W
4000W
50A /60A
80A
12VDC/24VDC
24VDC/48VDC
5000W
6000W
80A/100A/120A
48VDC
14VDC-130VDC
26VDC-130VDC /50VDC-160VDC
50VDC-160VDC
600W/720W
1920W/3840W
3840W/4800W/5760W
Battery Type Input Voltage Range Floating Charge Set Low Voltage Restored Low Voltage Shutdown set Over Voltage Protection Over Voltage Alarm
AC Charging Transfer Time
Waveform
DC Battery Specifications
GEL, AGM, SLA, FLD, LI, USER 12VDC:10.5-15VDC 24VDC:21-30VDC 48VDC:42-60VDC
12.9 13.6 V(1PCS battery) can be set
12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC
12VDC:10-10.9V
24VDC:20-21.8V 48VDC:40-43.6V
12VDC:16.7VDC 24VDC:33.4V 48VDC:66.8V
12VDC:15VDC 24VDC:30V 48VDC:60V
5A-35A(40A, 50A, 60A,70A Optional
Typical5-8ms(Including detection time)
Pure sine wave
Model External Size(mm)
L*W*H Gross Size(mm)
L*W*H Net Weight(kg)
Gross Weight(kg)
General Specifications
1000W
1500W
2000W
3000W
510*325*215mm
560*380*280mm
16
17
20
22
18
19
22
25
4000W
5000W
6000W
645*325*215mm
730*400*290mm
32/40 35/43
34/44 37/47
37/45 40
1
220VAC 230VAC Inverter With Charger Technical Specifications
Model
Inverter Specifications
1000W 1500W 2000W 3000W 4000W 5000W
6000W
8000W
10000W 12000W
Surge Power (1 second) 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 18000W 18000W
Surge Power (10 seconds) Surge Power (60seconds) Commercial Power
Range
1300W 1950W 2600W 3900W 5200W 6500W 7800W 10400W 13000W 15600W
1100W 1650W 2200W 3300W 4400W 5500W 6600W 8800W 11000W 13200W
220VAC:165V-275VAC 230VAC:173V-287VAC
220VAC:176V-264VAC 230VAC:184V-276VAC
AC Frequency Range
45-65HZ
AVR Voltage Range VAC
Output Frequency Range(AC mode)
DC Voltage Input Input Wave Form
220VAC/230VAC±10% Auto-sensing
220VAC:176V-264VAC 230VAC:184V-276VAC
Tracking automatically /shared frequency with the commercial inversion state:60/50±0.5 Hz
12VDC /24VDC
24VDC /48VDC Sine Wave ( Utility or Generator )
48VDC
Output Wave Form
Pure Sine Wave
Output Overload
Thermal Method Communication port
temperature Humidity
Short Circuit Protection
Line Mode Efficiency > Optimal Efficiency
105% < Load < 110% ± 10% : Fault ( Turn off output after 60 seconds) 110% < Load < 130% ± 10% : Fault ( Turn off output after10 seconds)
150% < Load ± 10% : Fault ( Turn off output after 1 seconds) Cooling fan in intelligent control42 fan rotates slowly to 45 fan rotates fast
RS232/WIFI/SNMP(Optional) -15+50 10%90%
Software Protection
95% >85%
Battery Type Input Voltage Range Floating Charge Set Low Voltage Restored Low Voltage Shutdown set Over Voltage Protection Over Voltage Alarm
AC Charging Transfer Time
Waveform
DC Battery Specifications
GEL, AGM, SLA, FLD, LI, USER 12VDC:10.5-15VDC 24VDC:21-30VDC 48VDC:42-60VDC
12.9 13.6 V(1PCS battery) can be set
12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC
12VDC:10-10.9V
24VDC:20-21.8V 48VDC:40-43.6V
12VDC:16.7VDC 24VDC:33.4V 48VDC:66.8V
12VDC:15VDC 24VDC:30V 48VDC:60V 5A-35A(40A, 50A, 60A,70A Optional
Typical5-8ms(Including detection time) Pure sine wave
2
Model External Size(mm)
L*W*H Gross Size(mm)
L*W*H
Net Weight(kg)
1000W 14
General Specifications
1500W 2000W 3000W 4000W 5000W 6000W
510*325*215mm
645*325*215mm
8000W 10000W 12000W 765*320*250
560*380*280mm
15
18
730*400*290mm
20 30
32
35
52
840*420*320
54
57
Gross Weight(kg)
16
17
20
23
33
35
38
55
57
60
220VAC 230VAC Hybrid Inverter With Controller Technical Specifications
Model
Inverter Specifications
1000W 1500W 2000W 3000W 4000W 5000W
6000W
8000W
10000W 12000W
Surge Power (1 second) 3000W 4500W 6000W 9000W 12000W 15000W 18000W 24000W 18000W 18000W
Surge Power (10 seconds) Surge Power (60seconds) Commercial Power
Range
1300W 1950W 2600W 3900W 5200W 6500W 7800W 10400W 13000W 15600W
1100W 1650W 2200W 3300W 4400W 5500W 6600W 8800W 11000W 13200W
220VAC:165V-275VAC 230VAC:173V-287VAC
220VAC:176V-264VAC 230VAC:184V-276VAC
AC Frequency Range
45-65HZ
AVR Voltage Range VAC
Output Frequency Range(AC mode)
DC Voltage Input Input Wave Form
220VAC/23 0VAC±10% Auto-sensing
220VAC:176V-264VAC 230VAC:184V-276VAC
Tracking automatically /shared frequency with the commercial inversion state:60/50±0.5 Hz
12VDC /24VDC
24VDC /48VDC Sine Wave ( Utility or Generator )
48VDC
Output Wave Form
Pure Sine Wave
Output Overload
Thermal Method Communication port
temperature Humidity
Short Circuit Protection
Line Mode Efficiency > Optimal Efficiency
105% < Load < 110% ± 10% : Fault ( Turn off output after 60 seconds) 110% < Load < 130% ± 10% : Fault ( Turn off output after10 seconds)
150% < Load ± 10% : Fault ( Turn off output after 1 seconds) Cooling fan in intelligent control42 fan rotates slowly to 45 fan rotates fast
RS232/WIFI/SNMP(Optional) -15+50 10%90%
Software Protection
95% >85%
3
“
Model MAX Solar Charger Current
Battery DC Voltage PV Voltage Input Range
MAX PV Power Input
MPPT solar charge controller
1000W 1500W 2000W 3000W 4000W 5000W 6000W 8000W 10000W 12000W
50A /60A
60A/80A
60A/80A
100A/120A
12VDC
24VDC/48VDC
48VDC/96VDC
14VDC-130VDC
24V:26VDC-130VDC/ 48V:50VDC-160VDC
48V:50VDC-160VDC 96V:98VDC-280VDC
600W/720W
1920W/3840W
2880W/3840W /4800W/5760W
4800W/5760W 9600W/11520W
Battery Type Input Voltage Range Floating Charge Set Low Voltage Restored Low Voltage Shutdown set Over Voltage Protection Over Voltage Alarm
AC Charging Transfer Time
Waveform
DC Battery Specifications
GEL, AGM, SLA, FLD, LI, USER 12VDC:10.5-15VDC 24VDC:21-30VDC 48VDC:42-60VDC
12.9 13.6 V(1PCS battery) can be set
12VDC:12.6-14.4VDC 24VDC:25.2-28.8VDC 48VDC:50.4-57.6VDC
12VDC:10-10.9V
24VDC:20-21.8V 48VDC:40-43.6V
12VDC:16.7VDC 24VDC:33.4V 48VDC:66.8V
12VDC:15VDC 24VDC:30V 48VDC:60V 5A-35A(40A, 50A, 60A,70A Optional
Typical5-8ms(Including detection time)
Pure sine wave
Model External Size(mm)
L*W*H Gross Size(mm)
L*W*H
Net Weight(kg)
1000W 16
General Specifications
1500W 2000W 3000W 4000W 5000W 6000W
510*325*215mm
645*325*215mm
560*380*280mm
17
20
730*400*290mm
22
32/40
34/44 37/45
8000W
10000W 12000W 765*320*250
840*420*320
60
62
65
Gross Weight(kg)
18
19
22
25
35/43
37/47 40/48
63
65
68