Sloan 111 Ess Crown Flushometer User Guide

111 ESS Crown Flushometer

Product Information

The Crown II product is no longer available as a complete
assembly, but repair parts are still available for a limited time.
The product is a flushometer, specifically a Crown flushometer. It
comes with various parts and accessories for repair and
maintenance.

The product is available in different finishes, including CP
(Chrome Plate), PVDPB (Polished Brass), PVDBN (Brushed Nickel),
PVDSF (Satin Chrome), and PVDGP (Gold Plated).

The parts list includes items such as covers, handle and cover
trim ring kits, handle assemblies, handle repair kits, vacuum
breakers, spud coupling assemblies, stop couplings, adjustable
tailpieces, control stop repair kits, locking vandal resistant
control stop caps, relief valves, piston kits, and filter
o-rings.

Product Usage Instructions

  1. When repairing or maintaining the Crown flushometer, refer to
    the parts list to identify the specific part needed for
    replacement.
  2. If the Crown flushometer was made prior to 2004, refer to the
    Naval flushometer section on page 36 for additional
    information.
  3. For tailpieces, control stops, and flush connections, refer to
    the Showerheads, Parts and Accessories Tab for more
    information.
  4. Ensure that the flow from the valve does not exceed the flow
    capability of the fixture. Opening the control stop beyond the
    fixture’s capacity may cause valve failure.
  5. In case of a valve failure, make sure that the fixture can
    accommodate a continuous flow from the valve.

Note: The information provided in this document is subject to
change without notice. Please consult the user manual for the most
up-to-date instructions and guidelines.

Repair Parts and Maintenance Guide
Crown® Flushometer Crown® II (Obsolete)

NOTE: Crown II is No Longer Available As A Complete Assembly. Repair Parts Remain Available For A Limited Time.

CROWN® SHOWN

1 2 3A
4 7

5B

3B

10B

7

6B

8

5A 9B

6A 8 9A 10A
NOTE: For Crown flushometers made 13 prior to 2004, please refer to Naval flushometer section on page 36

21 22
20
19 CN76 16A
16B

23
17 18

15
14
TAILPIECES, CONTROL STOPS 12 AND FLUSH CONNECTIONS
For additional information on 11 tailpieces, control stops and flush connections see Showerheads, Parts and Accessories Tab.
FINISH LEGEND CP CHROME PLATE 13A PVDPB POLISHED BRASS PVDBN BRUSHED NICKEL PVDSF SATIN CHROME PVDGP GOLD PLATED

PARTS LIST
Item No. Code No. Part No. Description
1. 0332006 CR-116 CP Cover 2. 0332030 CR-133 Cover O-ring 3. 0332045 CR-132-A CP Handle and Cover Trim Ring Kit (Includes items
3A & 3B) (CROWN® II ONLY) 0332046 CR-132-A PVDPB Handle and Cover Trim Ring Kit (Includes
items 3A & 3B) (CROWN® II ONLY) 0332048 CR-132-A PVDBN Handle and Cover Trim Ring Kit (Includes
items 3A & 3B) (CROWN® II ONLY) 0332049 CR-132-A PVDSF Handle and Cover Trim Ring Kit (Includes
items 3A & 3B) (CROWN® II ONLY) 3A. 0332035 CR-134 Cover Trim Ring (CROWN® ONLY)
0332009 CR-120 PVDPB Cover Trim Ring (CROWN® II ONLY) 0332032 CR-120 PVDGP Cover Trim Ring (CROWN® II ONLY) 0332033 CR-120 PVDBN Cover Trim Ring (CROWN® II ONLY) 0332034 CR-120 PVDSF Cover Trim Ring (CROWN® II ONLY) 3B. 0332005 CR-113 PVDPB Handle Trim Ring (CROWN® II ONLY) 0332028 CR-113 PVDBN Handle Trim Ring (CROWN® II ONLY) 0332029 CR-113 PVDSF Handle Trim Ring (CROWN® II ONLY) 4. 3332003 CR-1004-A Piston Kit ­ 1.6 gpf (6.0 Lpf) Water Closet 3332013 CR-1011-A Piston Kit ­ 1.28 gpf (4.8 Lpf) Water Closet 3332004 CR-1005-A Piston Kit ­ 1.0 gpf (3.8 Lpf Urinal 3332005 CR-1006-A Piston Kit ­ 0.5 gpf (1.9 Lpf) Urinal 3332017 CR-1015-A Piston Kit ­ 0.25 gpf (1.0 Lpf) Urinal 3332016 CR-1014-A Piston Kit ­ 0.125 gpf (0.5 Lpf) Urinal ALL PISTON KITS INCLUDE MAIN SEAT (see item 4 table to right) AND CR-124-A INSIDE COVER ASSEMBLY AS SHOWN IN ITEM 4. PISTON KIT COMPONENTS TABLE TO THE RIGHT.

Item No. Code No. Part No. Description

5A. 0302353 B-30-A ADA-Compliant Handle Assembly CP

5B. 0302390 B-73-A ADA-Compliant Handle Assembly CP

6A. 3332006 CR-1007 Handle Repair Kit 6B. 3302306 B-51-A Handle Repair Kit

7. 5301139 A-31

Handle Gasket ­ 48/pkg

8. 0302389 B-74-A Handle Grip Sub-Assembly ADA

9A. 0302309 B-56

Sleeve

9B. 0302109 B-7-A CP Socket Assembly

10A. 0302354 B-53 10B. 0301082 A-6

Handle Socket CP Handle Coupling

11. 3393004 V-600-AA 3/4″ x 9″ (19 x 229 mm) Vacuum Breaker – 6/pkg

3393006 V-600-AA 1-1/4″ x 9″ (32 x 229 mm) Vacuum Breaker – 6/pkg 3393007 V-600-AA 1-1/2″ x 9″ (38 x 229 mm) Vacuum Breaker – 6/pkg

12. 3323182 V-651-A High Back Pressure Vacuum Breaker Repair Kit

13. 3332000 CR-1008-A 3/4″ (19 mm) Spud Coupling Assembly 3332001 CR-1009-A 1-1/4″ (32 mm) Spud Coupling Assembly

3332002 CR-1010-A 1-1/2″ (38 mm) Spud Coupling Assembly

13A. SEE SLIP JOINT GASKETS AND RINGS TABLE ON BOTTOM, PAGE 25 14. 0308676 H-550 Stop Coupling

15. 0308801 H-551-A Adjustable Tailpiece (2-1/16″ (52 mm) long)

16A. 5308696 H-553 16B. 5308381 H-552

O-ring ­ 24/pkg Locking Ring ­ 12/pkg

17. 0388000 H-700-A 1″ Screwdriver Bak-Chek® Stop CP

0388001 H-700-A 3/4″ Screwdriver Bak-Chek® Stop CP 18. 3308853 H-541-ASD Control Stop Repair Kit

3308856 H-543-ASD Control Stop Repair Kit for 3/4″ Stops H-600, H-640

19. 0308612 H-622 0308843 H-577

CP Bonnet CP Bonnet ­ OBSOLETE

20. 3308840 H-573-A Locking Vandal Resistant Control Stop Cap includes H-573 Stop Cap CP and H-648 Friction Ring

0308848 H-582 21. 3308651 H-651

Locking Vandal Resistant Control Stop Cap CP Vandal Resistant Control Stop Cap Assembly

22. 3308866 H-574 Control Stop Cap w/Bumper (-YO Variation)

23. 3308867 H-576 24 3388017 H-1017

Control Stop Cap w/Extended Bumper (-YG Variation)
Flow Control (HEU Only) (Not Shown)

— 0305190 EL-190-A Handle Adapter (manual only) for Optima® version

For use w/H-700-A 1” & 3/4″ and H-600-A 1” Screwdriver Bak-Chek® Control Stops. For use w/H-600-A 3/4″ Screwdriver Bak-Chek® Control Stops.

ITEM 4. PISTON KIT COMPONENTS

Item Code No. Part No. Description

A. ***

CR-124-A Inside Cover Sub-Assembly

B. ***

***

Piston Cover

A

C. 5332095 CR-68-A Molded Cup ­ 12/pkg

D. 5328019 SH-406 Spring ­ 12/pkg

CN76 B

E. ***

***

Relief Valve

C

F. 0307116 G-95

Relief Valve Seat

D

G. ***

***

Piston Body

H. ***

CR-125-A Main Seat ­ 6/pkg

E

(1.0 gpf)

F

***

CR-170-A Main Seat ­ 6/pkg

G

(0.125 gpf, 0.25 gpf and 0.5 gpf)

I. 0307210 G-85

Filter O-ring

I

J. 0332124 CR-169 O-ring (for use with

H

CR-125-A main seat ONLY)*

5308958 H-589 O-ring* 6/pkg

J

* Components are NOT interchangeable *** Indicates component is NOT available separately

The information contained in this document is subject to change without notice.

35

Repair Parts and Maintenance Guide

Crown® Flushometer Crown® II (Obsolete)

TROUBLESHOOTING GUIDE

IMPORTANT: The CROWN ® flushometer is engineered for quiet operation. Excessive water flow creates noise, while too little water flow may not satisfy the needs of the fixture. Proper adjustment is made when plumbing fixture is cleansed after each flush without splashing water out from the lip AND a quiet flushing cycle is achieved.
Never open control stop to where the flow from the valve exceeds the flow capability of the fixture. In the event of a valve failure, the fixture must be able to accommodate a continuous flow from the valve.
ATTENTION INSTALLERS: With the exception of the control stop inlet, DO NOT USE pipe sealant or plumbing grease on any valve component or coupling! To protect the chrome or special finish of Sloan flushometers, DO NOT USE toothed tools to install or service these valves. Use our A-50 Super Wrench or other smooth-jawed wrench to secure couplings. Regulations for low consumption fixtures (1.6 gpf/6.0 Lpf closets and 1.0 gpf/3.8 Lpf urinals) prohibit use of higher flush volumes.
1. Valve DOES NOT function.
A. Control stop or main valve is closed. Open control stop or main valve.
B. Handle assembly is worn. Install Sloan handle repair kit, or replace handle.
C. Relief valve is worn and sticking in UP position. Replace piston.
2. Insufficient volume of water to adequately siphon fixture.
A. Control stop not open enough. Adjust control stop for desired delivery of water.
B. Urinal piston parts inside a closet valve. Replace piston parts with proper closet piston.
C. Low consumption valve installed on a non-low consumption fixture. Replace with proper flushometer. Crown® flushometers are not available with flush volume higher than 1.6 gpf/6.0 Lpf.
D. Inadequate volume or pressure at supply. Increase water pressure or supply (flow) to valve. Consult factory for assistance.

3. Length of flush too short (short flushing) or valve closes off immediately.
A. Piston assembly is not hand-tight. Screw the assembly hand-tight.
B. Enlarged bypass orifice from corrosion or damage. Install NEW inside parts kit to correct problem and update flushometer.
C. Urinal piston in closet flushometer. Replace piston with proper closet piston.
D. Low consumption piston installed in non-low consumption fixture. Replace with proper flushometer. Crown® flushometers are not available with flush volume higher than 1.6 gpf (6.0 Lpf).
E. Handle assembly worn. Install Sloan handle repair kit.
4. Length of flush too long (long flushing) or fails to close off.
A. Piston is not seating properly or bypass orifice is clogged because of foreign material, or bypass orifice is clogged by an invisible gelatinous film from “over-treated” water. Disassemble the working parts and wash thoroughly. NOTE: Size of the orifice in the bypass is of utmost importance for the proper metering of water into the upper chamber of the valve. DO NOT enlarge or damage this orifice. Replace piston if cleaning does not correct problem.
B. Line pressure has dropped and is not sufficient to force relief valve to seat. Shut off all control stops until pressure has been restored, then open them again.
C. Main seat is fouled with debris or is worn. Clean or replace main seat.
5. Leaking at handle assembly.
A. The B-85 seal may have deteriorated. Install new B-85 seal. NOTE: The B-85 seal will easily slide onto the bushing if it is wet.
B. Handle gasket has been omitted. Install A-31 handle gasket or Sloan handle repair kit.
C. Valve handle bushing is worn. Install Sloan handle repair kit.

COVER
BODY HANDLE COUPLING

COVER TRIM RING

STOP COUPLING
CONTROL STOP

COVER
BODY HANDLE TRIM RING

COVER TRIM RING

STOP COUPLING
CONTROL STOP

CARE AND CLEANING
DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean flushometers that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean

HANDLE ASSEMBLY
FLUSH CONNECTION (VACUUM BREAKER)

SUPPLY TAILPIECE FLANGE
OUTLET COUPLING

HANDLE ASSEMBLY
FLUSH CONNECTION (VACUUM BREAKER)

TAILPIECE
OUTLET COUPLING

SUPPLY FLANGE

cloth or towel.
While cleaning the bathroom tile, the flushometer should be protected from any splattering of cleaner. Acids and cleaning fluids will discolor or remove

SPUD COUPLING
CROWN® SHOWN

SPUD FLANGE

SPUD COUPLING SPUD FLANGE
CROWN® II SHOWN
OBSOLETE

chrome plating.

When assistance is required,

Piston

Water Closet

Urinal

please contact Sloan Technical

Identification Chart
Piston Color Cap Color

CR-1004-A

CR-1011-A

CR-1005-A

3332003

3332013

3332004

1.6 gpf (6.0 Lpf) 1.28 gpf (4.8 Lpf) 1.0 gpf (3.8 Lpf)

CR-1006-A

CR-1015-A

3332004

3332017

0.5 gpf (1.9 Lpf) 0.25 gpf (1.0 Lpf)

CR-1014-A 3332016 0.125 gpf (0.5 Lpf)

Support at: 1-888-SLOAN-14 (1-888-756-2614).

Stem Grooves
Barrel (Large Ribs or Small Ribs)

Cap Color

Green

Deep Purple

Yellow

Piston Color

Green

Green

Clear

Barrel

Large Ribs

Large Ribs

Small Ribs

Seat Color

Green

Green

Black

Grooves

2

0

1

The information contained in this document is subject to change without notice.

Red

Burgundy

Burgundy

Burgundy

­

­

Burgundy

Burgundy

2

1

36

Pink Burgundy
­ Burgundy
3

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals