BA304G-SS Loop-Powered Digital Indicators
Description: The product is a field and panel mounting
intrinsically safe digital indicator. It operates on a 4/20mA
loop-powered system and displays the input current in engineering
units. The product is available in different models and sizes.
Model Mounting: – BA304G: Field mounting – BA304G-SS: Field
mounting with 316 SS panel – BA324G: Field mounting – BA324G-SS:
Field mounting with 316 SS panel – BA307E: Panel mounting, 96 x
48mm – BA327E: Panel mounting, 96 x 48mm – BA308E: Panel mounting,
144 x 72mm – BA328E: Panel mounting, 144 x 72mm – BA307E-SS: Panel
mounting, 105 x 60mm with 316 SS panel – BA327E-SS: Panel mounting,
105 x 60mm with 316 SS panel Digits: – 4 x 34mm high – 5 x
29mm high + bargraph – 4 x 15mm high – 5 x 12.7mm high + bargraph
Enclosure Panel Material Cut-out (mm): – GRP: 90.0 +0.5/-0 x
43.5 +0.5/-0 – 316 SS: N/A (Not Applicable) – Noryl: 136 +0.5/-0 x
66.2 +0.5/-0 Certifications: The product has Intrinsic
IECEx, ATEX, and UKCA gas and dust safety certifications.
Additional approvals such as cFM and cETL are available. Please
refer to the full instruction manuals for more details.
Parameters: – Circuit: 4/20mA input with or without
loop-powered backlight – Optional alarms – Optional backlight
separately powered – Input parameters: Ui (30V), Ii (200mA), Pi
(0.84W) – Output parameters: Comply with Simple Apparatus
requirements Special Conditions for Safe Use: When installed
in Zone 0, the installation should prevent impact between the
aluminum label and iron/steel. In Group IIIC conductive dust
environments, the instrument terminals should have at least IP6X
protection. To avoid an electrostatic charge, the instrument
enclosure should only be cleaned with a damp cloth. When installed
in an Ex ta, tb px, py, pz, or e enclosure, the indicator will not
invalidate the enclosure certification, but it must be powered by a
suitably rated Zener barrier or galvanic isolator. Repair:
Faulty indicators should not be repaired by users. They should be
returned to BEKA associates or your local agent. Disposal:
Indicators should be correctly disposed of and not thrown in
household rubbish. Installation & Connections: For field
mounting models (BA304G, BA304G-SS, BA324G, BA324G-SS), there are
terminals for optional alarms and backlight. Terminals 2 and 4 are
internally linked for joining return 4/20mA wire. For panel
mounting models (BA307E, BA327E, BA308E, BA328E), there is a panel
clamp and a scale card tab for installation. Health & Safety
Requirements: The product complies with essential health and
safety requirements for loop-powered 4/20mA indicators.
Description
Field and panel mounting intrinsically safe, 4/20mA loop-powered digital indicators which display the input current in engineering units.
Model Mounting
BA304G
BA304G-SS Field BA324G mounting
BA324G-SS
BA307E BA327E
Panel mounting
96 x 48mm
BA308E BA328E
Panel mounting
144 x 72mm
BA307E-SS BA327E-SS
Panel mounting
105 x 60mm
Digits
4 x 34mm high
5 x 29mm high
+ bargraph
4 x 15mm high
5 x 12.7mm high
+ bargraph 4 x 34mm
high 5 x 29mm
high + bargraph 4 x 15mm
high 5 x 12.7mm
high + bargraph
Enclosure Panel material cut-out
mm
GRP
316 SS
GRP
N/A
316 SS
90.0 +0.5/-0 x 43.5 +0.5/-0
Noryl
136 +0.5/-0 x 66.2 +0.5/-0
316 SS
90.0 +0.5/-0 x 43.5 +0.5/-0
Intrinsic IECEx, ATEX and UKCA gas and dust safety certification. Other approvals, such as
cFM and cETL are available, please refer
to full instruction manuals for details.
Code: II 1 G
II 2 D
Ex ia IIC T5 Ga Ex ia IIIC T80°C Db IP66 field mounting Ex ia IIIC T80°C Db IP20 panel mounting -40°C Ta +70°C
Parameters:
Circuit
4/20mA input with or without loop powered backlight Optional alarms Optional backlight separately powered
Input parameters
Ui
Ii
Pi
Output parameters
Comply with
30V
200mA
0.84W
requirements for Simple
Apparatus
Special conditions for safe use – see certificates
BA304G BA324G
BA307E BA308E BA327E BA328E
BA307E-SS BA327E-SS
When installed in Zone 0, installation shall be such that an ignition due to impact between aluminium label and iron/steel is excluded.
When used in a Group IIIC conductive dust environments instrument terminals shall have at least IP6X protection. To avoid an electrostatic charge instrument enclosure should only be cleaned with a damp cloth.
When used in a Group IIIC conductive dust environments instrument terminals shall have at least IP6X protection. When installed in an Ex ta, tb px, py, pz or e enclosure, the indicator will not invalidate the enclosure certification, but the indicator must be powered by a suitably rated Zener barrier or galvanic isolator.
Repair
No attempt should be made to repair a faulty indicator, it should be returned to BEKA associates or to your local agent.
Disposal Indicators should be correctly disposed of, not in household rubbish.
Installation & connections: Field mounting models BA304G, BA304G-SS, BA324G, BA324G-SS
Terminals
11
for optional + 10
alarms
9 +8
Terminals – 14
for optional
– 13 + 12
backlight
Terminals 2 & 4 internally linked 1
2
for joining return 3 4 4/20mA wire.
Separately powered Loop powered Common
+ 4/20mA – input
Scale card tab
Back-box has four M6 clearance holes for surface mounting and two threaded M20 x 1.5 holes for cable entries.
Installation: Panel mounting models BA307E, BA327E, BA308E & BA328E
Align foot and body by turning screw anticlockwise
1
Gasket
22cNm (1.95lbf in) max. Finger tight plus one half turn DO NOT OVERTIGHTEN
2 Insert
3
Essential Health & Safety Requirements for loop powered 4/20mA indicators BA304G, BA304G-SS, BA324G,
BA324G-SS, BA307E, BA307E-SS, BA327E, BA327E-SS, BA308E & BA328E
UK
Installation: Panel mounting models
BA307E-SS & BA327E-SS
SCALE
9.304 TAG NUMBER
PE
Ex ia IIC T5 Ga
BA307E-SS
9.304 TAG NUMBER
SCALE
PE
1 Insert
Panel clamp
2 Scale card tab
Issue 1 28th February 2023
BEKA associates Ltd. Old Charlton Rd, Hitchin, Hertfordshire, SG5 2DA, UK Tel: +44(0)1462 438301 e-mail: [email protected]
web: www.beka.co.uk
3 22cNm (1.95lbf in) max. Finger tight plus one half turn DO NOT OVERTIGHTEN
Connections: Panel mounting models BA307E, BA327E, BA308E, BA328E, BA307E-SS and BA327E-SS
1 2 3 4 8 9 10 11 12 13 14
+
+-
+- + – –
Alarm 1
Alarm 2
Separately
powered
Terminals 2 & 4 are internally linked for
Terminals for optional alarms
Loop powered Common
joining return
Terminals for
4/20mA wire
optional backlight
Combined EU Declaration of Conformity
Description of Electrical Apparatus BA304G, BA304G-SS 4 digit; BA324G, BA324G-SS 5 digit field mounting (Intrinsically safe 4/20mA loop powered indicators)
BA307E, BA307E-SS, BA308E 4 digit; BA327E, BA327E-SS, BA328E 5 digit panel mounting (-SS models have a stainless steel enclosure)
Manufactured by BEKA associates Ltd, Old Charlton Road, Hitchin, Herts. UK. SG5 2DA
Council Directives this equipment complies with: 2014/34/EU (ATEX Directive) Relating to equipment and protective systems intended for use in potentially explosive atmospheres.
Provisions of the Directive fulfilled by the equipment: Group II Category 1G Ex ia IIC T5 Ga Ta -40°C to +70°C Group II Category 2D Ex ia IIIC T80°C Db (IP66 field IP20 panel) Ta -40°C to +70°C
Notified Body for EU-Type Examination and production INTERTEK ITALIA SPA 2575 Via Guido Miglioli, 2/A 20063 Cernusco sul Naviglio (MI) Italy.
EU-Type Examination Certificates ITS11ATEX27253X Issue 2 12th August 2015. ITS11ATEX27254X Issue 4 16th October 2017. ITS14ATEX28077X issue 1 19th August 2014.
Standards used: Compliant with EN IEC 60079-0:2018; EN 60079-11:2012 except in respect of those requirements referred to at item 16 of the Schedule.
2014/30/EU (EMC Directive)
Standards used: EN 61326-1:2013
2011/65/EU (RoHS Directive) relating to hazardous substances in electronic and electrical equipment.
2015/863/EU additional substances added by amending Annex II to Directive 2011/65/EU as regards the list of restricted substances.
mark first affixed in 2011
Authorised Signatory:
Issue 1 19th October 2022
Olivier Lebreton CEng MIET Managing Director
Display mode
P E
E
P
EE
Security Code
Enter code by pressing and P
to move to next digit. Code 0000
allows direct access to the menu
E
E
CONFIGURATION
Access to the configuration menu is obtained by pressing the ( and ) buttons simultaneously. If the indicator security code is set to the default 0000 the first parameter FunC will be displayed. If the indicator is protected by a security code, CodE will be displayed and the code must be entered to obtain access to the menu.
Please refer to the full instruction manual for detailed configuration information and for a description of the lineariser and the optional dual alarms.
E
E
When fitted alarm functions appear here
E
Only for 5 digit models
E
E
E
E
PE
PE
PE
PE
E
PE
E
PE
E
E
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
PE
Function
or to select
5td for standard function.
root for root extractor.
lin for lineariser
Resolution
or to select resolution of least significant
digit
Decimal point
or to select position of dummy decimal
point
Calibration using external current source
(Preferred method)
With accurate 4mA input current
set required zero display by
pressing
or and P
to move to the next digit
Similarly, using accurate 20mA input current set required full scale display
Any current between 4 and 20mA may be used providing
difference is > 4mA
Calibration using internal references (Input current may be any value)
Using 2Ero function set required
display at 4mA by pressing
or
and P
to move to the next digit
Similarly, using 5PAn function set required display at 20mA
Select type of bargraph display and define start and finish relative to digital display
Using the tYPE function select required bargraph justification by pressing or
Using the bArLo function set the digital display
at which the bargraph is required to start by
pressing or
and P to move to the
next digit. Similarly using the bArHi function set
digital display at which the bargraph is required
to finish
Function of ( Tare Function button in
display mode
Define Security Code
Reset indicator configuration
Press or
to toggle between 4-20mA and % of span
Press or
to turn tArE on or oFF
Enter by pressing
or and P to move to next digit
Press or
to select ConF to reset
indicator or LtAb to
reset lineariser to default
configuration.
Confirm selection by entering 5urE
by pressing or
and P to move to next digit
Manuals, certificates and datasheets can be downloaded from https://www.beka.co.uk/lpi01
Configuration menu
Old Charlton Rd, Hitchin, Hertfordshire, SG5 2DA, UK Tel: +44(0)1462 438301 e-mail: [email protected]
web: www.beka.co.uk