ECT600GS Gas Cooktop
Product Information
The product is a cooking appliance with the following product
codes:
- ECT600GS
- ECT60WCX
- ECT60GX
- ECT900GX
This manual provides instructions on the proper installation and
use of the appliance. It is important to read and understand the
manual, even if you are already familiar with the product. Please
keep the manual in a safe place for future reference. Note that any
repairs to the appliance should only be done by authorized service
persons or engineers to maintain the guarantee.
Warning – General Safety
- The appliance should only be installed and connected by
licensed gasfitters or authorized persons. - Built-in appliances should only be used after they have been
installed in suitable built-in units and work surfaces that meet
local authority standards. - Repairs to the appliance should only be carried out by trained
registered authorized service persons or engineers. - The technical and identification data for the hob can be found
on the reference data plate fixed to the underside of the
appliance. Consult this plate before making any electrical
connections. - The electrical connections must be made by specialist
installers who comply with legal and regulatory requirements in
each country. If the cable is damaged, it must be replaced by the
manufacturer, after-sale service, or authorized technical staff to
avoid hazards. - Do not use or store flammable materials near the appliance. Do
not spray aerosols in the vicinity of the appliance while it is in
operation. Do not modify the appliance. Do not use the appliance as
a space heater. Do not put combustible material in the immediate
surrounds of the appliance.
Correct Use
- People who are unable to use the device safely due to physical,
sensory, or mental capabilities, inexperience, or ignorance should
not use the device without supervision or instruction from a
responsible person. - The appliance should be used only for normal domestic cooking
and frying of food. It must not be used as a work surface or
storage surface. Additions or modifications to the appliance are
not permitted. - Do not place or store flammable liquids, highly inflammable
materials, or fusible objects (e.g. plastic film, plastic,
aluminum) on or near the appliance. Do not heat an empty pan on the
appliance.
Children’s Safety
- Keep small children away from the appliance as the cooking
zones will become hot during use. - The appliance is not intended for use by young children or
infirm persons without supervision. - Ensure that young children are supervised to prevent them from
playing with the appliance.
Safety During Use
- There is a risk of burns from the appliance if used carelessly.
Cables from electrical appliances must not touch the hot surface of
the appliance or hot cookware. - Overheated fats and oils can ignite quickly. Switch off the
cooking zones after each use to reduce fire hazards. - Users with implanted pacemakers should keep their upper body at
least 30 cm away from cooking zones that are switched on to avoid
any risks associated with electromagnetic fields. - Avoid placing objects made of metal, such as knives, forks,
spoons, and saucepan lids, on the cooking surface as they can get
hot.
cooking
USAGE AND CARE GUIDE
PRODUCT CODE:
PRODUCT CODE:
ECT600GS ECT60WCX
ECT60GX ECT900GX
This manual explains the proper installation and use of your appliance, please read it carefully before using even if you are familiar with the product. The manual should be kept in a safe place for future reference. In case of failure, only the Authorized Technical Service may repair this hob. Otherwise the guarantee will be null and void.
Warning
General Safety
The appliance may only be installed and connected by licensed gasfitters / authorized persons.
Built-in appliances may only be used after they have built in to suitable built-in units and work surfaces that meet local authority standards.
Repairs to the appliance must only be carried out by trained registered authorized service persons / engineers.
The technical and identification data for the hob is located on the reference data plate fixed to the underside of the appliance.
This reference data plate must be consulted before making the electrical connections. The electrical connections must be made by specialist installers to the legal and
regulatory, requirements in each country. If the cable is damaged in any way it must be replaced by the manufacturer or after sale
service or by authorized technical staff, to avoid hazard. DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN
OPERATION. DO NOT MODIFY THIS APPLIANCE. DO NOT USE THIS APPLIANCE AS A SPACE HEATER. DO NOT PUT COMBUSTIBLE MATERIAL IMMEDIATE SURROUNDS OF THE APPLIANCE.
Correct Use
People (including children) who, because of their physical, sensory or mental capabilities or their inexperience or ignorance are not able to use the device safely, should not use this device without supervision or instruction by a responsible person.
This appliance should be used only for normal domestic cooking and frying of food. The appliance must not be used as a work surface or as a storage surface. Additions or modifications to the appliance are not permitted. Do not place or store flammable liquids, highly inflammable materials or fusible objects
(e.g. plastic film, plastic, aluminum) on or near the appliance. Do not heat an empty pan on the appliance.
Children’s Safety
The cooking zones will become hot when you cook. Therefore, always keep small children away from the appliance.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Safety During Use
There is the risk of burns from the appliance if used carelessly. Cables from electrical appliances must not touch the hot surface of the appliance or hot
cookware. Overheated fats and oils can ignite very quickly. Warning! Fire hazard! Switch the cooking zones off after each use. Users with implanted pacemakers should keep their upper body at least 30 cm from
cooking zones that are switched on. Risk of burns! Do not place objects made of metal, such as knives, forks, spoons and
saucepan lids on the cooking surface, as they can get hot.
Special conditions, which shall be avoided, e.g. marine environment, and any conditions necessary to ensure optimum performance.
The appliances can be used in freezing conditions.
Safety When Installation
DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN
OPERATION. WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR CARAVANS, IT
SHALL NOT BE USED AS A SPACE HEATER. This hotplate must be installed in accordance with:
AS/NZS5601 – Gas Installations (for Australia) current edition NZS 5261 Code of Practice for the Installation of Gas Burning Appliances and Equipment (for New Zealand) This standard may not be now current!! Local gas fitting regulations
2
AS/NZS 3000 Electrical Installations (Wiring Rules) Building codes Any other relevant statutory regulations. Check the gas type label on the underside of the hotplate, adjacent to the gas connection to ensure it corresponds to the installation gas supply. If in doubt contact the supply authority. The power supply cord (supplied) must not touch against any hot surfaces and must be placed so that its temperature does not exceed 75 degrees at any point along its length. After connecting to gas, check for leaks using soapy solution, never a naked flame. Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B 10mm diameter and no more than 1.0metre in length. Any hose assembly used must be restrained from accidental contact with the flue outlet of an under bench oven.
How To Avoid Damage To The Appliance
Do not use the cooking zones with empty cookware or without cookware. The ventilation gap of 5mm between the worktop and front of the unit underneath it must
not be covered. DO NOT MODIFY THIS APPLIANCE.
Safety When Cleaning For cleaning, the appliance must be switched off and cooled down. For safety reasons, the cleaning of the appliance with steam jet or high pressure cleaning
equipment is not permitted.
Disposing Of The Device When disposing of the device, do not bring it to regular municipal waste containers. Instead, bring it to electrical and electronic waste recycling and reuse center. A relevant label has been put on the device, its instructions manual, or the package. The device has been manufactured of recyclable material. By bringing the old device to recycling collection center, you show that you care about nature. Ask your local environmental care authority for information on location of such facilities.
3
Product Description
Burner
ECT600GS Pan support
Panel knobs
No Model . 1 ECT600GS
2 ECT60WCX
3 ECT60GS
4 ECT900GX
Burner* 1W+ 2SR+ 1A
FSD Wit h
Pan su p p or t s Enamel
1W+ 2SR+ 1A
Wit h Cast iron
1R+ 2SR+ 1A
Wit h Cast iron
1W+1R +2SR+1A With
Cast iron
Knob p osit ion Fr o n t
Fr o n t
Ri g h t
Front
Tot al gas con su p t ion LPG: 27.5MJ/ h NG: 26.0MJ/ h LPG: 30.5MJ/ h NG: 29.5MJ/ h LPG: 30.5MJ/ h NG: 29.5MJ/ h LPG: 39.6MJ/ h NG: 39.0MJ/ h
Over view
* Note: For burner: W= Triple Ring Wok burner, R= Rapid burner , SR= Sem i- Rapid burner, A= Auxiliary burner
4
Accessory Name
User Manual Sealing tape
Additional labels
Picture ( for reference only, physical unit maybe different)
You have additional rating label in accessory bag, suggest attach it onto a surface where it can be read e.g. inside surface of adjacent cupboard
Installation clip
Screws ST4.2×24
LPG Injectors
Elbow &Washers
Quantity 1
1 roll 1 set
4 sets
4 pcs
4 pcs
1 Elbow, 3 washers
Natural gas 1
regulator
Technical Specifications
Model
Product Dimensions (h x w x d) mm
ECT60WCX
85x580x500
Cut-out Size
( w x d)mm
552 x 470
ECT600GS
85x580x500
552 x 470
ECT60GX ECT9 0 0 GX
85x580x500 85x860x500
552 x 470 827 x 470
Electrical Connection
220-240V/50Hz 220-240V/50Hz 220-240V/50Hz 220-240V/50Hz
Rated Input Power 0.5W 0.5W 0.5W 0.5W
5
Installation
Before Installation:
Before cutting into any bench tops, ensure the minimum clearances to walls, adjacent surfaces and overhead surfaces required by the relevant gas appliance installation code (see above) will comply. Dimensions are specified in millimeters (mm) Overhead cupboards and range hood = 650 mm. Side and rear clearance = 200 mm to any burner edge. Overhead exhaust/ceiling fan = 750 mm Horizontal surfaces adjacent the hob = less than or equal to the hob height. Ensure there is sufficient clearance to fit the regulator and/or flexible hose connection with the hotplate in the installed position. Before the appliance is installed into the cabinet, please make sure any transit protection is removed.
When you have installed the hob, make sure that
The GPO (general purpose outlet) must always be in an accessible position. The supply connection point, test point and natural gas regulator adjustment screw (for Natural gas
installation) are accessible for testing and/or adjustment with the hotplate in the installed position.
TO BE INSTALLED ONLY BY AN AUTHORIZED PERSON.
1. Cupboard Cutting Bench top thickness, 30 40 mm (3 4 cm).
Model: ECT60WCX,ECT600GS, ECT60GX
Model: ECT900GX
6
2. Place Burner Box Apply the adhesive sealing tape to the underside lip of the burner box. Shown at G opposite. Place burner box into cutout hole and fit clamping brackets to clamp the hotplate to the bench.
3. Fit Burners And Trivet.
Replace burners and ensure they are correctly repositioned over the ignitor (S) and thermocouple (T). The ignitor (S) must be clean for trouble free sparking. Test burner ignition and burner flame for correct operation, If burner is placed correctly it will not rotate on its supports. The Triple Ring (Wok) burner (diagrams below) does not fit over the igniter or thermocouple but must be placed on its supports. Make sure trivet is fitted onto its locator on burners and can’t rotate after assembled.
3. Electrical Connection Install a 10 amp general purpose outlet (GPO) in accordance with relevant electrical standards and/or codes of practice applicable. The power supply cord (supplied) must not touch against any hot surfaces and must be placed so that its temperature does not exceed 75 at any point along its length.
7
After having installed the hotplate, the GPO must always be in an accessible position.
ECT60WCX , ECT600GS, ECT60GX
ECT900GX
Wiring diagram
4. Gas Connection
Install in accordance with relevant gas standards and/or codes of practice applicable. Connect the elbow fitting to the appliance gas manifold connection, and check that seals between the elbow and manifold connection are in place and in good condition.
For Natural gas: connect the natural gas appliance regulator (pictured opposite) with integral test point using approved gas thread tape or compound to the elbow fitting.
For Universal LPG: see page 9
Ensure the supply connection point, test point and natural gas regulator adjustment screw (for Natural gas installation) are accessible for testing and/or adjustment with the hotplate in the installed position. Where a flexible hose assembly is used, ensure it is approved to AS/NZS 1869, Class B. Any hose assembly used must be restrained from accidental contact with the flue outlet of an under bench oven. This hose assembly shall be suitable for connection to a fixed consumer piping outlet located as follows: Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the width of the appliance to a distance of 250 mm.
After connecting to gas, check for leaks using soapy solution, never a naked flam e.
Inlet connection region for flexible hose
Fit the duplicate data plate (supplied in separate bag) on a surface adjacent to the hotplate, for example, the inside of the cupboard door so it is clearly visible for any service technician.
SETTING THE GAS PRESSURE: Fit a manometer with a 6 mm rubber hose to the test point on the regulator (for natural gas). Light Triple Ring and Auxiliary burner on and adjust test point pressure to 1.00 kPa. Turn the two burners off and on again and recheck the pressure is same as set previously or adjust as required. TEST FOR CORRECT OPERATION: After installation and adjusting burner pressure using test point, each burner ignition and operation must be tested individually and with all burners operating. This testing must be done by the installer before leaving.
8
9
ADJUSTING THE BURNER MINIMUM FLAME HEIGHT:
NOTE: This adjustment can only be performed by the installer or an authorised service personnel. The minimum burner flame is factory adjusted for the gas type stated on the gas type label adjacent to the gas connection and should not require adjustment. Adjustment may be required if the hotplate has been converted from Natural gas to Universal LPG or vice versa. GAS CONVERSION INSTRUCTIONS: The manufacturers servicing instructions detail how authorised personnel may convert the hotplate from Natural gas to Universal LPG or from Universal LPG to Natural gas. Contact the manufacturer or agent as required.
For model ECT60WCXECT600GSECT60GX
ADJUSTED FOR NATURAL GAS 1.0kPa
NOZZLES
Gas consumption,
mm
DIAMETER
MJ/h
WOK
1.70
13.0
Rapid
1.40
9.5
SEMI RAPID
1.10
6.0
AUXILIARY
0.90
4.5
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been replaced
this label must to be affixed to the name plate of the
appliances.
Natural Gas regulator is to be fitted and adjusted
ADJUSTED FOR ULPG 2.75KPa
NOZZLES mm
DIAMETER
Gas consumption, MJ/h
WOK
0.98
13.0
Rapid
0.90
10.0
SEMI RAPID
0.7
6.75
AUXILIARY 0.55
4.0
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been
replaced this label must to be affixed to the name
plate of the appliances.
Change the NG regulator to LPG by a qualified
person.
For model ECT900GX
ADJUSTED FOR NATURAL GAS 1.0kPa
NOZZLES
Gas consumption,
mm
DIAMETER
MJ/h
WOK
1.70
13.0
Rapid
1.40
10.0
SEMI RAPID
1.10
6.0
AUXILIARY
0.90
4.0
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been replaced
this label must to be affixed to the name plate of the
appliances.
Natural Gas regulator is to be fitted and adjusted
ADJUSTED FOR ULPG 2.75KPa
NOZZLES mm
DIAMETER
Gas consumption, MJ/h
WOK
0.98
13.0
Rapid
0.90
10.0
SEMI RAPID
0.7
6.3
AUXILIARY 0.55
4.0
Replacement of the nozzles must be performed by a
qualified person. Once the nozzles have been
replaced this label must to be affixed to the name
plate of the appliances.
Change the NG regulator to LPG by a qualified
person.
10
Start Using Your Appliance ECT60WCXECT600GS
ECT60GX
ECT900GX
Description
Zone indicators Flame power
Explanation These show which zone is under control.
Flame power of the zones, is the highest.
is the lowest and
The hotplates are fitted with mains powered electronic spark ignitors, so must be connected to mains power supply (i.e. nominal 220~240 V ac) to operate. If power is not available, the hotplate will still work but the burners will have to be lit with a match or similar.
11
Depressing the gas control knob of any burner will activate the spark ignition for all burners. To light the burner, turn the gas control knob to the High Flame setting of the burner to be lit, while at the same time depressing the gas control knob to activate the spark ignition. Once the burner is alight continue to depress the gas control knob for 5 10 seconds to allow the flame safeguard to activate. If when you release the gas control knob, the burner flame goes out the flame safeguard has not heated up enough so repeat the ignition procedure after waiting 1 minute for gas to disperse. If problems with burner lighting persist, refer to the TROUBLESHOOTING section of these instructions.
If power is not available, light a match or similar, then turn the gas control knob for the burner to be lit, to the High Flame setting. Once again if problems with burner lighting persist, refer to the TROUBLESHOOTING section of these instructions.
When burner lights, adjust desired flame height. On finishing, turn control knob to off position marked with a black DOT.
BURNER AND UTENSIL CHOICE
The maximum utensil (pan) diameters in millimeters
(mm) for each burner are: 1. For Natural Gas hotplates
Auxiliary (small) and Semi-Rapid (medium) = 195 mm
Rapid (large) = 230 mm Triple ring (wok) = 270 mm
2. For Universal LPG hotplates Auxiliary (small), Semi-Rapid (medium) and
Rapid (large) = 195 mm Triple ring (wok) = 230 mm
The minimum utensil (pan) diameters in millimeters (mm) for each burner are:
Auxiliary (small) = 80 mm and Semi-Rapid (medium) = 140 mm Rapid (large) and Triple ring (wok) = 195 mm
For best efficiency and to ensure utensil handle does not overheat, place the utensil centrally on the burner and adjust the flame height so all the flame remains under the utensil.
12
Maintenance & Troubleshooting
Cleaning and maintenance should be carried out with the appliance cold especially when cleaning the enameled parts. Avoid leaving alkaline or acid substances(lemon juice, vinegar etc.) on the surfaces.
STAINLESS STEEL The stainless steel hob of the hotplate must be cleaned regularly (e.g. weekly) to ensure long life expectancy of the hotplate. Ensure hotplate has cooled. Wash down with warm soapy water and rinse with clean water. Dry with a clean soft cloth. A specialized stainless steel cleaning fluid may be used. NOTE: Ensure that wiping is done along with the grain of the stainless steel to prevent any unsightly crisscross scratching patterns from appearing.
TRIVETS (UTENSIL SUPPORTS) Enameled parts must only be washed with a sponge and soapy water or with non-abrasive products. Rinse with clean water. Dry with a clean soft cloth.
BURNERS
Replace burners and ensure they are correctly repositioned over the igniter (S) and thermocouple (T). The igniter (S) must be clean for trouble free sparking. Test burner ignition and burner flame for correct operation.
The Triple Ring (Wok) burner (diagrams below) does not fit over the igniter or thermocouple but must be placed on its supports. If burner is placed correctly it will not rotate on its supports.
Remove trivets from hob. Ensure burners are cool. Remove the burners enameled cap (C) and aluminum burner crown (F).
Wash down with warm soapy water and rinse with clean water. Dry with a clean soft cloth.
Use a cotton bud, tooth brush, or some other item to clean out any incrustations or dirt from the four holes marked(H)
(b) removal of components for service– (ii) pilot and flame safeguard; (iii) ignition system; (v) gas control; (vii) hotplate top; (ix) thermocouple;
(c) parts replacement– (iv) electronic ignition;
(d) adjustments– (iv) ignition (spark gap);
13
TROUBLESHOOTING
Servicing of the hotplates must only be done by an authorised service representative, and the hotplate must not be modified. Power must be disconnected before any servicing or maintenance is conducted. DO NOT MODIFY THIS APPLIANCE. It is recommended the hotplate serviced by an authorized person at least every 2 years. This service is not covered by warranty. Abnormal conditions include: Excessively yellow or sooting flame type.
Flame lifting off the burner ports.
Flame lighting back into the burner (normally associated with a popping sound).
Objectionable odour of the flames combustion products.
Should a faulty condition develop in the hotplate that is not described above, refer to the following table first for possible causes and remedies prior to contacting an authorised service representative. Servicing beyond the remedies listed shall only be undertaken by an authorised service representative.
FAULT
POSSIBLE CAUSE
No spark when gas control knob depressed.
No power.
Loose sparker cable. Burner not aligned properly.
REMEDY Check plugged in and switched on. Check mains circuit breaker. Call authorised representative. Remove and re-fit burner.
Burner not lighting when spark ignition working.
Gas supply off. Burner not aligned properly. Burner ports blocked.
Check gas supply valve on. Remove and re-fit burner. Remove, clean and replace burner.
Burner goes out when control knob released.
Uneven flame pattern or slight flame lifting. At minimum flame setting the flame is too high.
Small flame on High setting.
Flame safeguard not activated. Flame safeguard faulty connection or broken. Burner ports blocked.
Turndown control setting incorrect. Regulator faulty. Gas supply pressure low. Incorrect injector fitted. Blocked injector or gas supply tube.
Re-light, allow more time for flame safeguard to activate. Call authorised representative.
Remove, clean and replace burner.
Call authorised representative. Call authorised representative. Call authorised representative. Call authorised representative. Call authorised representative.
Incorrect utensil size.
Flame too high on High setting.
Regulator faulty. Incorrect injector fitted.
Incorrect utensil size.
Refer to operating instructions utensil choice. Call authorised representative. Call authorised representative. Refer to operating instructions utensil choice.
14
Pronto Service + Support: 1800 440 335 Email: [email protected]
HEAD OFFICE 65 Glynburn Road, Glynde SA 5070 Ph: 08 8165 1012
www.euroappliances.com.au