Euramco Safety Ub20 Ramfan Turboforce Ventilators Owner's Manual

UB20 Ramfan TurboForce Ventilators

Product Information

The RAMFAN UB20 and UB30 are utility blower/exhausters designed
to deliver clean, safe air in confined spaces. The UB20 has a part
number ED7002 and can deliver airflow of 980 cubic feet per minute
(cfm) with a power input of 115 volts and 9.5 amps (start) and 2.5
amps (run). It has a motor output of 1/3 horsepower and a
protection class of IP55. Its dimensions are 14 x 12 x 13 inches
and it weighs 17 lbs. The sound level at 3 feet is 74 dB(A).

The UB30 has a part number EJ4002 and can deliver airflow of
2420 cfm with a power input of 115 volts and 33 amps (start) and 8
amps (run). It has a motor output of 1 horsepower and a protection
class of IP55. Its dimensions are 20 x 15.5 x 12 inches and it
weighs 37 lbs. The sound level at 3 feet is 90 dB(A).

Both models are thermally protected for indoor/outdoor use with
thermal overload protection and automatic reset. The motor will
restart without warning after protector trips. If motor thermal
protection trips, disconnect unit and determine cause. Do NOT
change make or model of fan or motor.

Product Usage Instructions

Before starting the fan for the first time, read the manual
carefully. Do not start the fan if there are any signs of shipping
damage, particularly to blade, guards, or housing. If ANY damage is
suspected, STOP and call your dealer immediately.

Keep children away from the unit to avoid any injury. Ensure
that the unit is inaccessible to children when not attended.

Always operate the unit with a grounding plug and a grounded
electrical outlet. Ensure that the switch is in the OFF position
prior to connecting to power. Use cords of suitable size for
amperage load. Never operate a unit with a damaged power cord, as
this may lead to electrical or fire hazards.

UB20/ UB30
Owner’s Manual
Euramco
Safety,
Inc.
2746
Via
Orange
Way
Spring
Valley,
CA
91978
USA
USA
1.800.4.RAMFAN

Tel
+1.619.670.9590
Fax
+1.619.670.7345
[email protected]

www.EuramcoSafety.com

SM–UB20
Rev
A

Preface
Thank you for purchasing the RAMFAN® UB20 or UB30 utility blower manufactured by Euramco Safety, Inc. For more than 30 years Euramco Safety has been on the cutting edge of industrial, fire, and marine ventilation products. Each and every one of our blower/exhausters, smoke ejectors, PPV & LSV fans and accessories represent the finest technologies available. Every product is constructed to demanding and exact specifications for quality, performance, and reliability.
When human life depends on having a fan that can deliver clean, safe air, you have only one choice you can trust: RAMFAN. Explore our website and online catalog at www.EuramcoSafety.com and discover how RAMFAN can make a difference in the field!
This manual covers operation and maintenance procedures for the RAMFAN UB20 and UB30 utility blower/exhausters. All product information in the publication is based on the most current information available at the time of printing. Euramco Safety, Inc. reserves the right to make changes at any time without notice.
READ MANUAL BEFORE STARTING FAN FOR FIRST TIME!

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

1

Table of Contents
1 | Specifications/Warnings……………………………………………………………………………………………………………….. 3 2 | Features & Benefits ………………………………………………………………………………………………………………….. 3, 4 3 | Safety Precautions ……………………………………………………………………………………………………………………. 4, 5 4 | Operation……………………………………………………………………………………………………………………………………… 5 5 | Maintenance……………………………………………………………………………………………………………………………… 5, 6 6 | Troubleshooting …………………………………………………………………………………………………………………………… 6 7 | Spare Parts……………………………………………………………………………………………………………………………….. 7, 8

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

2

1 |Specifications/ Warnings

MODEL Part Number Airflow Power Power input max. (Start / Run) Motor output max. Protection class Height x Width x Length Weight Sound level @ 3′ / 1 m

UB20 ED7002 980 cfm 115V, 50/60Hz 9.5A / 2.5A 1/3 Hp IP55 14 x 12 x 13 in 17 lbs 74 dB(A)

ED8002 1392 m³/h 230V, 50/60Hz 4.8A / 1.3A 0.25 kW IP55 36 x 31 x 33 cm 8 kg 74 dB(A)

UB30 EJ4002 2420 cfm 115V, 50/60Hz 33A / 8A 1 Hp IP55 20 x 15.5 x 12 in 37 lbs 90 db(A)

* Specifications are subject to change without notice. Some values are approximate.

EJ8002 3429 m³/h 230V, 50/60Hz 17A / 5A 0.8kW IP55 51 x 39 x 31 cm 17lbs 90 db(A)

CAUTION!

Thermally Protected for Indoor/Outdoor Use To protect the user, this unit is equipped with thermal overload protection and automatic reset. Motor will restart without warning after protector trips. If motor thermal protection trips, disconnect unit and determine cause.

Do NOT change make or model of fan or motor.

2 | Features & Benefits

RAMFAN® combines high performance turbofan design with high strength polymers to create a line of rugged, portable turbo blowers. The UB-Line is ideal for general use, confined space ventilation and delivers the highest airflow in its class. The double-wall, polyethylene casing is light-weight, corrosion and chemical resistant and handles the bumps and falls of any job site.
The 8″/20 cm UB20 turbo blower is at the heart of the RAMFAN industrial ventilation systems that provide you with the complete solution for common confined space ventilation applications. The multi-purpose blower and exhauster delivers powerful airflow in a compact and lightweight package.
· Compact & Lightweight · Integrated Duct Adapter · Cord Strap · 15’/4.6 m Extended Reach Power Cable · Ultra Quiet · Easily attaches Quick-CoupleTM Duct Canister for Exhaust/Suction
The 12″/30 cm UB30 takes design cues from the UB20 in a larger form. The larger blower/exhauster produces a higher airflow for use in larger confined spaces. The larger the area you are trying to ventilate the more airflow you’ll

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

3

need. The RAMFAN® UB30 has unmatched performance for a fan its size. It is built with a durable housing to withstand industrial workspace environments.
· 2 Integrated Duct Adapters · Dual Voltage/ Dual Frequency · Stackable design feature · Cord Strap · 15’/4.6 m Extended Reach Power Cable
3 | Safety Precautions
Before Operation
Before starting for the first time: DO NOT START fan if there are any signs of shipping damage, particularly to blade, guards, or housing. If ANY damage is suspected, STOP and call your dealer immediately.
Keep children away: Do not allow children to play with or around the unit, which could result in injury. Be sure the unit is inaccessible to children when not attended.
Keep unit grounded: Always operate the unit with a grounding plug and a grounded electrical outlet. A grounding plug is an essential safety feature that helps reduce the risk of shock or fire. Always ensure the switch is in the OFF position prior to connecting to power.
Protect power cord from damage: Use cords of suitable size for amperage load. Never operate a unit with a damaged power cord, as this may lead to electrical or fire hazards.
Extension Cords: Extension cords must be grounded and able to deliver the appropriate voltage to the unit.
Do not use speed control device: To reduce the risk of fire or electric shock, do not use fans with a solid- state speed control device.
Handle with care: Do not drop or throw the unit. Rough treatment can damage the components or wiring and create a hazardous condition.
Run on stable surface: Start only if blower is sitting in a stable and upright position. While on level surface and running at full speed, the blower should not move around. If unit is moving, check rubber feet for damage and replace if necessary.
Secure during transport: When transporting in a vehicle, secure the unit to prevent sliding and possible injury to vehicle occupants.
During Operation
Airflow Direction: When using the blower, note the directional airflow indicator on the external housing.

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

4

Keep out of water: Never operate the unit in pooled or standing water, as this may create a risk of injury from electrical shock. Do not store outdoors. If electrical wiring or components become wet, thoroughly dry them before using the unit.
Safety: Proper ear and eye protection must be worn while blower is running. Keep fingers and hands clear of blade. Do not move blower while it is running.
Keep air intakes clear: Do not clog or block air intakes, this may occur if operated to close to loose lightweight objects such as clothing or leaves. This can cause the unit to overheat and result in a fire or electrical hazard.
Keep away dust and dirt: Do not allow dust, dirt, or other particles to be drawn into the air intakes. Dirt in the motor can cause it to overheat, resulting in a fire or electrical hazard. If the motor gets dirty, clean it using an air hose.
Allow repair only by qualified person: Immediately stop the unit upon hearing excessive mechanical noise or vibration. Do not attempt to disassemble or repair the unit if you are not qualified to do so. You can perform regular maintenance or troubleshooting, however complex problems need to be repaired by an authorized service technician.
For information about authorized repair, call Euramco Safety Customer Service at +1 (619) 670-9590.
4 | Operation
1. Read the Owner’s Manual completely before starting fan.
2. Wear both eye and ear protection.
3. Position the fan on a level surface.
4. Plug in to a standard outlet with the correct voltage and amperage for the unit. Set the switch to ON. Check for proper operation before leaving the unit unattended. Do not move or carry the blower while it is running
5 | Maintenance
LOCK-OUT / TAG-OUT: When performing any maintenance, always follow all additional safety precautions that your company may have for lock-out / tag-out procedures.
POWER OFF: Always turn the power OFF and unplug the unit before performing maintenance procedures. All the service procedures below are to be executed with the unit unplugged. Perform before each use or as needed.
DO NOT DISSASSEMBLE blower for maintenance reasons.
INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at regular intervals. Periodically, inspect internal wiring for bare wires, insecure fasteners, and discoloration. Remove and repair any damaged wiring as needed. Failure to do so may lead to electrical shock or a fire hazard.

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

5

CLEAN AIR INTAKES: Clean off any accumulated lint or other materials from the finger guards. A build up will reduce the airflow and may cause the motor to overheat and become a fire hazard. NEVER operate fan with damaged or missing finger guards.
CLEAN EXTERIOR: Clean fan periodically to remove accumulated dust or particles using a commercially available biodegradable cleaning solution. DO NOT use solvents containing chlorinated hydrocarbons (i.e. MEK, Acetone)
EXTERIOR INSPECTION: Evaluate exterior components and make sure they are properly installed. Inspect the fan for loose fasteners at least once every 6 months depending on frequency of use. Tighten any loose fasteners immediately. DO NOT overtighten fasteners.
Listen to the unit for abnormal sounds. Check rubber feet for excessive wear or breakage. Contact Euramco Safety for replacement parts and installation instructions.
DO NOT WET MOTOR OR WIRING: To prevent damage to electrical components, do not use a duct or pressure washer to clean a blower. If electrical components do become wet, dry them immediately.

6 | Troubleshooting

WARNING: Execute all the service procedures below with the blower OFF and power cord unplugged.

“FS” or Field Solutions can be handled by the technician in the field | “AST” or Authorized RAMFAN Service Technician

PROBLEM
Motor won’t run

CAUSE
No power to machine Switch not turned on Blower impeller jammed Intake or exhaust blocked Thermal cut off has been tripped

Switch is broken
Loose wiring Motor runs but impeller Severe jolt has caused motor turns erratically or scrapes mount to bend and impeller to rub
Severe jolt caused motor to slip out of mount and impeller to rub Unit vibrates excessively Accumulation of soil on impeller Blower impeller has lost balance
Blower impeller has been bent Bent motor shaft

See Above
FS FS FS FS FS
AST AST AST
AST
FS AST AST AST

SOLUTION
Plug in the unit; check circuit breaker or fuse Turn on the switch Remove material jamming wheel Turn machine off and allow to cool, then remove blockage Allow blower to cool down and motor will restart automatically Call distributor or Euramco for replacement switch
Check wiring and tighten as needed Remove motor from housing, then replace or repair bent motor mount Remove motor from housing, then re-install motor into mount correctly Clean blower impeller Balance or replace blower impeller
Replace blower impeller Replace motor

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

6

7 | Spare Parts Contact factory for replacement parts and installation instructions.

Model UB20
Corresponding Bubble No.
1 2 4 8 10 11 32a 32b

RAMFAN P/N
BL011 ST010 ED4001 EZP80783007 FZ-9540K46 ED4003 ED0108 ED0208

Description
Impeller Stator Intake Grill Retaining Clip Rubber Foot w/washer (4) Exhaust Grill Junction Box complete with mounting parts and cable (115V) Junction Box complete with mounting parts and cable (230V)

To order spare parts call Euramco Safety +1.619.670.9590 or email [email protected]

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

7

Model UB30
Corresponding Bubble No.
1 4 5 10 11 32a 32b

RAMFAN P/N
ST030 EJ4001 BL016 EB4001 FZ-9540K58 ED0408 ED0508

Description
Stator Housing Impeller Intake/ Exhaust Grill Rubber Foot w/washer (4) Junction Box complete with mounting parts and cable (115V) Junction Box complete with mounting parts and cable (230V)

To order spare parts call Euramco Safety +1.619.670.9590 or email [email protected]

UB20/UB30
Owner’s
Manual
|
Euramco
Safety,
Inc.
|
SM–UB20
Rev
A

8