Corning Dmrug2678 Digital Medium-power Remote Unit Owner's Manual

DMRUG2678 Digital Medium-Power Remote Unit

Product Information

This product is manufactured by Corning Optical Communications.
The user manual for this product is referenced as LAN-3091-AEN and
contains detailed instructions on how to use the product.

RUOP Info

The RUOP Info section provides information about the current
status of RU alarms. These alarms include Link Alarm, Digital HW
ALM, Temperature Alarm, Low Transmission Alarm, Overflow Alarm, DC
Voltage Lower Alarm, and Over Power Consumption Alarm. The firmware
mismatch alarm is also included.

DLRU Config

The DLRU Config section allows you to configure various settings
for the RU. It includes RF info, Carrier info, and OP info.

RF Info

The RF Info section provides various RF information for the RU.
It includes parameters such as RF Switch, DL ATT (Downlink
Attenuation), UL ATT (Uplink Attenuation), Work Mode, Service off
alarm, and MIMO (Multiple Input Multiple Output).

Carrier Info

The Carrier Info section provides information about the carrier
settings for the RU.

OP Info

The OP Info section displays the current optical port connection
status and information reading volume of the device.

Downlink/Uplink Config

The Downlink/Uplink Config section allows you to configure
settings related to downlink and uplink power.

Downlink Output Power Config (Power Sharing Process)

This step-by-step process guides you on how to configure the
downlink output power for power sharing. It involves setting the
Carrier Info and RIU ATT parameters to meet the DCU input power
range.

Uplink Gain Config

The Uplink Gain Config section provides instructions on how to
configure the uplink gain. It involves setting the RIU UL ATT, DCU
UL ATT, and RU UL ATT parameters.

Product Usage Instructions

RU Overview & Alarm

  1. Click on RU to enter the Overview interface.
  2. View the current status of RU alarms, such as Link Alarm.

RU Parameter Config

RF Info

  1. Click on RU1 to read various RF information of RU.
  2. Configure the RF Switch, DL ATT, UL ATT, Work Mode, Service off
    alarm, and MIMO parameters according to the recommended
    values.

Carrier Info

Refer to the figure to gather carrier information for
configuration.

OP Info

The OP Info section provides information about optical port
connection status and reading volume. Refer to the figure for more
details.

Downlink Output Power Config (Power Sharing Process)

  1. Set the Carrier Info, including operator info and carrier
    info.
  2. Set the DL ATT parameter to a suitable value to meet DCU input
    operation range.
  3. Set the RIU ATT to meet DCU input power range.

Uplink Gain Config

  1. Configure the RIU UL ATT parameter according to chapter
    5.1.2.
  2. Configure the DCU UL ATT parameter according to chapter
    5.2.2.2.
  3. Configure the RU UL ATT parameter according to chapter
    5.4.2.2.

Refer to the provided tables for the range and default values of
each ATT parameter.

Figure 162. RUOP Info Figure 163.RUOP InfoMore

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 128

5.4.2.4 Other Info

Figure 164.RUOther info
5.5 DLRU Config 5.5.1 RU -> Overview &Alarm
Click RU to enter the Overview interface and view the current status of RU alarms (e.g., Link Alarm).

Each alarm is defined as follows: Link Alarm Digital HW ALM Temperature Alarm Low Transmission Alarm Overflow Alarm DC Voltage Lower Alarm Over Power Consumption Alarm Firmware Mismatch Alarm

Figure 165.RUOverview

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 129

Drag the scroll bar to view more information (e.g., Temperature) as shown in the figure below.
Figure 166.RU Overview More
5.5.2 RU Parameter config
5.5.2.1 RF info

Figure 167. RF Info

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 130

Click RU RU1 to read various RF information of RU, as shown in the figure below:

SN

Parameter

Range

Recommend value

1

RF Switch

ON/OFF

ON

2

DL ATT

(0~20)

10

3

UL ATT

(0~20)

10

4

Work Mode

Normal DL force uplink UL force uplink

Normal

5

Service off alarm

Disable Enable

Enable

6

MIMO

MIMO 1 MIMO 2

5.5.2.2 Carrier info

Figure 167.RF info

Figure 168.RU RU 4Carrier Info
5.5.2.3 OP info
The OP Info list box displays the current optical port connection status and information reading volume of the device, as shown in the figure below.

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 131

Figure 169.RU RU 1OP Info Figure 170.RU RU 1OP InfoMore

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 132

5.6 Downlink/Uplink Config
5.6.1 Downlink Output Power Config (Power Sharing Process)
Step 1. Set Carrier Info in Chapter 5.3.1.3, including the operator info, carrier info. The DL ATT can be set to default value in power sharing config.

Figure 154. Power sharing
Step 2. Set the power sharing parameters in chapter 5.3.1.4 – Assign each operator’s power share (percentage). – Select the carrier’s power assignment mode for each operator (Density /Even). Density mode: power assignment based on carrier bandwidth. Even mode: power assignment based on the carrier number. – Config MIMO 1 and MIMO 2 channel. – Select the calculate button to active the value, then the DL ATT value in Step 1 will be automatically calculated. – Select the `Power Share Lock’ button to lock the ATT config. – The system will automatically emit the output target power based on power sharing configuration if the DCU input power is within the operation range.

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 133

Step 3. Set RIU ATT to meet DCU input power range according to chapter 5.1.2 – Set RIU high gain mode (ON/OFF) and DL ATT to suitable value to meet DCU input operation range.

High Gain Mode

DL ATT

Total Gain

ON (Gain = -7dB)

0~25

-7~-32dB

OFF (Gain = -30dB)

0~25

-30~-55dB

– The DCU input power target is -7dBm, and the RIU suggested input power range is 10~37dBm, so that please config RIU high gain mode and DL ATT according to the input power.

RIU Input

High Gain Mode

Power(dBm) (ON/OFF)

DL ATT (0~25)

Total Gain(dB) Target Output Power

10~25

ON (Gain = -7dB)

Gain=-10~-25 -17~-32

-7dBm

25~37

OFF (Gain = -30dB) Gain=-2~-14

-32~-44

-7dBm

In this case, please config the DCU to the following config. The detailed config is listed in chapter 5.2.2 High Gain mode = OFF DCU DL ATT changes from 20dB to 0dB after antenna connection.

5.6.2 Uplink Gain Config

The Total Uplink Gain = -2dB – RIU UL ATT – DCU UL ATT – RU UL ATT Step 1. Config the RIU UL ATT according to chapter 5.1.2 Step 2. Config the DCU UL ATT according to chapter 5.2.2.2 Step 3. Config the RU UL ATT according to chapter 5.4.2.2 The range of each ATT is listed as below.

SN

ATT Range(dB)

Default Value(dB)

1

0~25

20

2

0~20

20

3

0~20

10

Config Description chapter 2.1.2 chapter 2.2.2.2 chapter 2.4.2.2

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 134

5.7 Case
2TO1 2×2 MIMO Case

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 135

4TO1 2×2 MIMO Case

Refer to the table below for EveronTM 6000 Parameters.
EveronTM 6000 Parameters_Build

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 136

Release Version

SN

Unit

Version

1

System version

Everon_6000_SYSTEM_P2.V01.04.01.68build9

2

RIU

Everon_6000_RIU_P2.V01.00.00.10build9

3

RIU-FDD

Everon_6000_RIU_P2.V02.00.00.04build9

4

DEU-25G

Everon_6000_DEU_P2.V01.00.03.63build9

5

DEU-10G

Everon_6000_DEU_P2.V02.00.02.15build9

6

DCU

Everon_6000_DCU_P2.V01.00.03.54build9

7

DLRU-3.5 Everon_6000_DLRUH_P2.V01.00.04.55build9

8

DLRU-M

Everon_6000_DLRUM_P2.V02.00.02.12build9

9

DLRU-L

Everon_6000_DLRUL_P2.V02.00.02.10build9

10

DMRU-3.5 Everon_6000_DMRUH_P2.V01.00.03.29build9

11

DMRU-FDD Everon_6000_DMRUF_P2.V02.00.00.16build9

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 137

6. APPENDIX: LED Functionality and Color Definition

SFP Plug out Optic Link Fail
Optic Link OK CPRI Link OK

Optical LED definition
SFP Plug out 1. Optic cable disconnected 2. SFP fail
2.1 SFP fault 2.2 SFP warning 2.3 SFP alarm 3. CPRI link down 1. Optic cable connected 2. SFP OK 3. CPRI link down 1. Optic cable connected 2. SFP OK 3. CPRI link up

Green (SYNC)
OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON

Amber (LOS) OFF ON ON ON ON ON ON ON ON ON OFF OFF OFF

LED ALM RUN Power

ALM/RUN/Power LED definition Description
1. Alarm 2. Device detect (Identify and is controlled from DCU) 3. No alarm 1. The system is up and running 2. Software or hardware failure 1. Power on 2. Power off

Color Red Red Flash (1Hz, 10s) OFF Green Flash(1Hz) OFF Green OFF

Corning Optical Communications

User Manual I LAN-3091-AEN I Page 138

Corning Optical Communications LLC · 4200 Corning Place · Charlotte, NC 28216 USA 800-743-2675 · FAX: 828-325-5060 · International: +1-828-901-5000 · www.corning.com/opcomm Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2023 Corning Optical Communications. All rights reserved. LAN-3091-AEN / January 2023