Pedrollo Bc 418 Submersible Pumps Instruction Manual

BC 418 Submersible Pumps

Product Information: BC Submersible Pumps

The BC Submersible Pumps are designed for multiple applications
such as domestic, civil, and industrial use. These pumps are
double-channel pumps that can handle sewage water and have a
sufficiently long power cable. The product complies with EN 60335-1
IEC 60335-1 CEI 61-150 and EN 60034-1 IEC 60034-1 CEI 2-3 safety
standards. The product is certified by DNV ISO 9001: QUALITY for
management system. The product has options available on request and
comes with patents, trade marks, and models.

Performance Range:

The product has a flow rate of up to 51 l/min and a total
manometric head of up to 16 metres. The product can handle solid
bodies with a diameter of up to 50 mm.

Construction Characteristics:

  1. Pump Body: Cast iron with an Epoxy Electro Coating treatment
    for greater resistance to corrosion, with threaded port in
    compliance with ISO 228/1
  2. Base: Stainless steel AISI 304
  3. Impeller: Double Channel type AISI 304 micro-cast stainless
    steel
  4. Motor Casing: Stainless steel AISI 304 for BC 10/50; Cast iron
    with an Epoxy Electro Coating treatment for BC 15/50, BC 20/50
  5. Motor Shaft: Stainless steel AISI 431
  6. Double Mechanical Seal in Oil Chamber: Seal Model MG1-14D SIC;
    Shaft Diameter; Position Motor side Pump side; Stationary ring
    Silicon carbide Silicon carbide; Rotational ring Graphite Silicon
    carbide; Elastomer NBR NBR
  7. Bearings: Pump Model BC 10/50 6203 ZZ / 6203 ZZ; BC 15/50, BC
    20/50 6303 2RS – C3 / 6203 ZZ
  8. Capacitor: EN 60252-1/A1 (only for single-phase versions)
  9. Electric Motor: Electric motors produced to a high quality
    standard, subjected to the most rigorous checks to ensure excellent
    insulation. BCm: single-phase 220 V – 60 Hz with thermal overload
    protector incorporated into the winding

Product Usage Instructions:

  1. Make sure that the power cable is sufficiently long for outdoor
    applications. The standard EN 60335-2-41 states that the power
    cable must be 10 m long for outdoor applications.
  2. Install the pump in a suitable location where it can handle
    sewage water and solid bodies with a diameter of up to 50 mm.
  3. Connect the pump to a power source that complies with the
    product specifications.
  4. Turn on the pump and allow it to run until it reaches its
    maximum performance range as specified in the user manual.
  5. Maintain the pump by checking and cleaning it regularly to
    ensure that it operates at optimal performance.

BC
Submersible pumps

DOUBLE-CHANNEL
Sewage water Domestic use Civil use Industrial use

PERFORMANCE RANGE
· Flow rate up to 850 l/min (51 m³/h) · Head up to 16 m

APPLICATION LIMITS
· 5 m maximum immersion depth
(with a sufficiently long power cable)
· Maximum liquid temperature +40 °C · Passage of suspended solids up to Ø 50 mm · Minimum immersion depth for continuous service:
­ 290 mm for BC 10/50
­ 330 mm for BC 15/50
­ 360 mm for BC 20/50

CONSTRUCTION AND SAFETY STANDARDS
· Power cable length:
­ 5 m for BC 10/50
­ 10 m for BC 15/50, BC 20/50,
· Float switch for single-phase versions

EN 60335-1 IEC 60335-1 CEI 61-150

EN 60034-1 IEC 60034-1 CEI 2-3

CERTIFICATIONS
Company with management system certified DNV ISO 9001: QUALITY

INSTALLATION AND USE
BC submersible pumps are suitable for draining dirty and sewage water in domestic and civil applications. They come equipped with a DOUBLE-CHANNEL stainless steel impeller and are capable of pumping liquids containing short fibred suspended solids up to Ø 50 mm. They are ideal for pumping sewage, waste water, surface water and water mixed with mud in locations such as blocks of flats and detached houses. These pumps distinguish themselves for their reliability, which can be best appreciated under automatic operating conditions in fixed installations.
PATENTS – TRADE MARKS – MODELS
· Patent n. EP2313658 · Patent n. IT0001428923
OPTIONS AVAILABLE ON REQUEST
· BC10/50 pumps with a 10 m power cable.
N.B.: Standard EN 60335-2-41 states that the power cable must be 10 m long for outdoor applications
· Single-phase pumps without float switch · Other voltages

46108Hz | | GEBNCERAL CATALOGUE 60 Hz

CHARACTERISTIC CURVES AND PERFORMANCE DATA

60 Hz n= 3450 min-1

Head H (metres) 4

0 0
17 16
BC20/50 15 14 BC15/50 13 12
BC10/50 11 10 9 8 7 6 5 4 3 2 1 0
0 50 100
0

50 50
150 200 250
10

100 100

300 350
20

400 450 500
30
Flow rate Q 4

150
550 600

200 150

US g.p.m. Imp g.p.m.
feet
50

DOUBLE-CHANNEL

40

30

20

10

0
650 700 750 800 850 l/min0 1

40

50

m³/h

MODEL Single-phase Three-phase

BCm 10/50

BC 10/50

POWER (P2)

m³/h

Q

kW HP

l/min

0.75

1

0

3

6 12 18 24 30 36 42 45 51

0 50 100 200 300 400 500 600 700 750 850

12 11 10.3 8.6 6.9 5 3.6 2

BCm 15/50

BC 15/50

1.1

1.5 H metres 14.5 13.5 12.8 11.2 9.5 7.8 6.1 4.5 2.8 2

BCm 20/50

BC 20/50

1.5

2

Q = Flow rate H = Total manometric head

16 15 14.4 12.8 11.1 9.5 7.9 6.2 4.5 3.7 2 Tolerance of characteristic curves in compliance with EN ISO 9906 Grade 3B.

GENERAL CATALOGUE 60BCHz | | 604H19z

BC

DOUBLE-CHANNEL

POS. COMPONENT

CONSTRUCTION CHARACTERISTICS

1 PUMP BODY

Cast iron with an Epoxy Electro Coating treatment for a greater resistance to corrosion, with threaded port in compliance with ISO 228/1

2 BASE

Stainless steel AISI 304

3 IMPELLER

DOUBLE CHANNEL type AISI 304 micro-cast stainless steel. The DOUBLE CHANNEL impeller permits one to obtain an excellent performance and a high energy efficiency, developing a greater pressure and guaranteeing the pumping of solid bodies with a diameter of up to 50 mm. Undoubtedly the best solution for the drainage of waste water.

4 MOTOR CASING

Stainless steel AISI 304

5 MOTOR CASING PLATE Stainless steel AISI 304 for BC 10/50 Cast iron with an Epoxy Electro Coating treatment for BC 15/50, BC 20/50

6 MOTOR SHAFT

Stainless steel AISI 431

7 DOUBLE MECHANICAL SEAL IN OIL CHAMBER

Seal
Model
MG1-14D SIC

Shaft
Diameter
Ø 14 mm

Position
Motor side Pump side

Stationary ring
Silicon carbide Silicon carbide

Materials
Rotational ring
Graphite Silicon carbide

Elastomer
NBR NBR

Double mechanical seal with an intermediate oil chamber, with silicon carbide chute slides for a greater resistance to abrasion and wear and for a longer life of the pump.

8 BEARINGS

Pump

Model

BC 10/50

6203 ZZ / 6203 ZZ

11

BC 15/50, BC 20/50

6303 2RS – C3 / 6203 ZZ

9 CAPACITOR

EN 60252-1/A1

(only for single-phase versions)

10 ELECTRIC MOTOR
Electric motors produced to a high quality standard, subjected to the most rigorous checks to ensure excellent insulation. The impregnation of the winding, achieved with high quality resins, is followed by treatment in an oven for up to eight hours, thus ensuring the long working life of the motor.
BCm: single-phase 220 V – 60 Hz with thermal overload protector incorporated into the winding
BC: three-phase 380 V – 60 Hz
­ Insulation: class F ­ Protection: IP X8

11 POWER CABLE
Power cable encapsulated in epoxy resin both in the area of the grommets and at the point where the wires exit the sheath, resulting in an absolute insulation from moisture and water infiltration.
H07 RN-F” type (with Schuko plug for single-phase versions only)
Standard length: ­ 5 metri for BC 10/50, ­ 10 metri for BC 15/50, BC 20/50

12 FLOAT SWITCH (only for single-phase versions)

9 8 10 8
12 1 2

6 4 7 5
3

46200Hz | | GEBNCERAL CATALOGUE 60 Hz

DIMENSIONS AND WEIGHT
a

Typical installation

p (minimum)

h h1
f

e

DN

d

b

c

(minimum)

MODEL Single-phase Three-phase

BCm 10/50

BC 10/50

BCm 15/50

BC 15/50

BCm 20/50

BC 20/50

PORT DN
2″

Passage

of solids

a

b

c

DIMENSIONS mm

f

h h1 d

451

Ø 50 mm 115 95 155 200 484 169 60

514

variable

e

p

kg 1~ 3~ 16.2 15.0

500 500 18.8 17.2

21.0 18.8

ABSORPTION
MODEL Single-phase BCm 10/50 BCm 15/50 BCm 20/50

220 V 6.3 A 8.5 A 10.0 A

VOLTAGE 110 V 13.5 A ­ ­

127 V 12.0 A
­ ­

CAPACITOR
MODEL Single-phase BCm 10/50 BCm 15/50 BCm 20/50

CAPACITANCE

220 V

110 V or 127 V

25 F – 450 VL

35 F – 450 VL

35 F – 450 VL

­

35 F – 450 VL

­

MODEL Three-phase BC 10/50 BC 15/50 BC 20/50

220 V 4.2 A 5.7 A 7.4 A

VOLTAGE 380 V 2.4 A 3.3 A 4.3 A

440 V 2.2 A 2.9 A 3.7 A

PALLETIZATION

MODEL Single-phase Three-phase

BCm 10/50

BC 10/50

BCm 15/50

BC 15/50

BCm 20/50

BC 20/50

GROUPAGE n. pumps 45 30 30

CONTAINER n. pumps 60 45 45

GENERAL CATALOGUE 60BCHz | | 604H21z