CHC 5638 Clovis Extra Large Chandelier
Product Information: Clovis Extra Large Chandelier
Item Number: CHC 5638
Notice: This light fixture should be installed in accordance
with all applicable, local installation codes, and by a person
familiar with the construction and operation of it, as well as the
hazards involved. Inspect item and contents carefully. If any
damage or defect is found, do not install. Retain all packaging
material until installation is complete and approved.
Tools Required (Not Included):
- Phillips Screwdriver
- Slotted Screwdriver
- Slip Joint Pliers
- Measuring Tape
- Wire Strippers
- Chain Pliers
- Wire Cutters
Product Usage Instructions:
- Carefully remove all parts from the box and place them on a
clean, soft surface. - Remove collar loop (D) from chain (F) by removing quick link
(E). - Install the mounting plate (B) to the junction box and secure
it with mounting screws (C). - Secure collar loop (D) to the mounting plate (B) using pliers
to tighten the locknut. - Install the canopy (G) to the collar loop (D) and secure it
with the collar ring (H). - Determine the desired overall length and the amount of chain
(F) needed. Shorten the chain using chain pliers. Keep the extra
chain. - Attach the chain (F) to the collar loop (D) and the fixture
loop (I) using quick links (E). Secure the quick links (E). - Attach the chains (J) to the hooks on the metal frame (K) and
the hooks on the fixture loop (I). Refer to diagram 1 & 2. - Thread the fixture wire and ground wire through the chain (F).
Note: When you reach the collar loop (D), ensure there is no
tension on the wires. Cut excess wires, leaving enough to reach the
junction box. - Separate two sides of the molded wire and strip insulation on
each 5/8. - Loosen collar ring (H) and carefully let the canopy (G) slip
down the chain (F). - Twist all fixture wires together and slip them through the
center hole of collar loop (D). Note: Untwist wires and separate
them to prepare for connection. - Wrap the fixture ground wire (bare copper) around the green
grounding screw. Tighten. Continue the fixture ground wire and
connect it to the supply ground wire (usually green or bare copper)
using a wire nut (A). Note: It is imperative that the fixture is
grounded. - Connect the fixture neutral wire (ribbed) to the supply neutral
wire (usually white) using a wire nut (A). - Connect the fixture hot wire (smooth with markings) to the
supply hot wire (usually black) using a wire nut (A). Caution: Do
not reverse the hot and neutral connections. - Make sure all wire connections are tight, then carefully tuck
them into the junction box. - Install the canopy (G) to the collar loop (D) and secure it
with the collar ring (H). - Install light bulbs into the sockets.
ASSEMBLY INSTRUCTIONS
Diagram 3
A B C D E G H F E I
Diagram 1
J
Diagram 2
K Bulbs not included
Clovis Extra Large Chandelier
Item # CHC 5638
NOTICE:
This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.
TOOLS REQUIRED (NOT INCLUDED):
Phillips Screwdriver
Slotted Screwdriver
Slip Joint Pliers
Measuring Tape
Wire Strippers
Chain Pliers Wire Cutters
1. Carefully remove all parts from the box. Place on a clean, soft surface. 2. Remove collar loop (D) from chain (F) by removing quick link (E). 3. Install mounting plate (B) to the junction box and secure with
mounting screws (C). 4. Secure collar loop (D) to mounting plate (B) using pliers to tighten
locknut. 5. Install canopy (G) to collar loop (D) and secure with collar ring (H). 6. Determine desired overall length, and amount of chain (F) needed.
Shorten chain using chain pliers. (Keep extra chain) 7. Attach chain (F) to collar loop (D) and fixture loop (I) using quick
links (E). Secure quick links (E). 8. Attach chains (J) to hooks on metal frame (K) and hooks on fixture
loop (I). See diagram 1 & 2. 9. Thread fixture wire and ground wire through chain (F).
NOTE: When you reach the collar loop (D), ensure there is no tension on the wires. Cut excess wires, being sure to leave enough to reach the junction box. 10. Separate two sides of molded wire, and strip insulation on each 5/8″. 11. Loosen collar ring (H) and let canopy (G) slip down chain (F) carefully.
M
LI ST ED
US
LED
ASSEMBLY INSTRUCTIONS
Diagram 3
A B C D E G H F E I
Diagram 1
J
Diagram 2
K Bulbs not included
Clovis Extra Large Chandelier
Item # CHC 5638
NOTICE: This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.
12. Twist all fixture wires together. Slip through center hole of collar loop (D). NOTE: Untwist wires and separate to prepare for connection.
13. Wrap fixture ground wire (bare copper) around the green grounding screw (see diagram 3). Tighten. Continue fixture ground wire and connect to supply ground wire (usually green or bare copper) using wire nut (A). NOTE: It is imperative that the fixture is grounded.
14. Connect fixture neutral wire (ribbed) to the supply neutral wire (usually white) using wire nut (A).
15. Connect fixture hot wire (smooth with markings) to the supply hot wire (usually black) using wire nut (A). CAUTION: Do not reverse the hot and neutral connections.
16. Make sure all wire connections are tight, then carefully tuck into the junction box.
17. Install canopy (G) to collar loop (D) and secure with collar ring (H). 18. Install light bulbs into the sockets.
Care Instructions: Clean only with a soft dry cloth or feather duster. Do Not use abrasive or chemical agents.
M
LI ST ED
US
LED