CHC 5010 Danvers Medium Chandelier
Product Information
Product Name: Danvers Medium Chandelier
Item Number: CHC 5010
Bulbs: Not included
Product Usage Instructions
- Carefully remove all parts from the box. Place on a clean, soft
surface. - Remove collar loop (D) from chain (H) by removing quick link
(E). - Install mounting plate (B) to the junction box and secure with
mounting screws (C). - Secure collar loop (D) to mounting plate (B) using pliers to
tighten locknut. - Install canopy (F) to collar loop (D) and secure with collar
ring (G). - Determine desired overall length, and amount of chain (H)
needed. Shorten chain using chain pliers. (Keep extra chain) - Install rod (J) to fixture body (M).
- Attach chain (H) to collar loop (D) and fixture loop (I) using
quick links (E). Secure quick links (E). - Thread fixture wire and ground wire through chain (H). Note:
When you reach the collar loop (D), ensure there is no tension on
the wires. Cut excess wires, being sure to leave about 12″ to reach
the junction box. - Separate two sides of molded wire, and strip insulation on each
5/8″. - Loosen collar ring (G) and let canopy (F) slip down chain (H)
carefully. - Twist all fixture wires together, and slip through center hole
of collar loop (D). Note: Untwist wires and separate to prepare for
connection. - Wrap fixture ground wire (bare copper) around the green
grounding screw. Tighten. Continue fixture ground wire and connect
to supply ground wire (usually green or bare copper) using wire nut
(A). Note: It is imperative that the fixture is grounded. - Connect fixture neutral wire (ribbed) to the supply neutral
wire (usually white) using wire nut (A). - Connect fixture hot wire (smooth with markings) to the supply
hot wire (usually black) using wire nut (A). Caution: Do not
reverse the hot and neutral connections. - Make sure all wire connections are tight, then carefully tuck
into the junction box. - Install canopy (F) to collar loop (D) and secure with collar
ring (G). - Install light bulbs into the sockets.
- Hang glass discs (L) to the hooks on ends of brackets (K).
ASSEMBLY INSTRUCTIONS
Diagram 1
A CB
D E
F
G H E
I
Diagram 2
J M
K
Diagram 3
L (5pcs)
Bulbs not included
N L (5pcs)
Danvers Medium Chandelier
Item # CHC 5010
NOTICE: This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.
TOOLS REQUIRED (NOT INCLUDED):
Phillips Screwdriver
Slotted Screwdriver
Slip Joint Pliers
Measuring Tape
Wire Strippers
Chain Pliers Wire Cutters
1. Carefully remove all parts from the box. Place on a clean, soft surface. 2. Remove collar loop (D) from chain (H) by removing quick link (E). 3. Install mounting plate (B) to the junction box and secure with
mounting screws (C). 4. Secure collar loop (D) to mounting plate (B) using pliers to tighten
locknut. 5. Install canopy (F) to collar loop (D) and secure with collar ring (G). 6. Determine desired overall length, and amount of chain (H) needed.
Shorten chain using chain pliers. (Keep extra chain) 7. Install rod (J) to fixture body (M). 8. Attach chain (H) to collar loop (D) and fixture loop (I) using quick
links (E). Secure quick links (E). 9. Thread fixture wire and ground wire through chain (H).
NOTE: When you reach the collar loop (D), ensure there is no tension on the wires. Cut excess wires, being sure to leave about 12″ to reach the junction box. 10. Separate two sides of molded wire, and strip insulation on each 5/8″. 11. Loosen collar ring (G) and let canopy (F) slip down chain (H) carefully. 12. Twist all fixture wires together, and slip through center hole of collar loop (D). NOTE: Untwist wires and separate to prepare for connection.
M
LI ST ED
US
ASSEMBLY INSTRUCTIONS
Diagram 1
A CB
D E
F
G H E
I
Diagram 2
J M
K
Diagram 3
L (5pcs)
Bulbs not included
N L (5pcs)
Danvers Medium Chandelier
Item # CHC 5010
NOTICE: This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.
13. Wrap fixture ground wire (bare copper) around the green grounding screw (see diagram 1). Tighten. Continue fixture ground wire and connect to supply ground wire (usually green or bare copper) using wire nut (A). NOTE: It is imperative that the fixture is grounded.
14. Connect fixture neutral wire (ribbed) to the supply neutral wire (usually white) using wire nut (A).
15. Connect fixture hot wire (smooth with markings) to the supply hot wire (usually black) using wire nut (A). CAUTION: Do not reverse the hot and neutral connections.
16. Make sure all wire connections are tight, then carefully tuck into the junction box.
17. Install canopy (F) to collar loop (D) and secure with collar ring (G). 18. Install light bulbs into the sockets. 19. Hang glass discs (L) to the hooks on ends of brackets (K).
See diagram 2. 20. Hang the remaining glass discs (L) to hooks (N) on the bottom of
fixture body. See diagram 3.
Care Instructions: Clean only with a soft dry cloth or feather duster. Do Not use abrasive or chemical agents.
M
LI ST ED
US