Scigiene Mb-p6080 Electronic Pipette Controller Instruction Manual

Scigiene Mb-p6080 Electronic Pipette Controller Instruction Manual

Scigiene logoELECTRONIC PIPETTE CONTROLLER
Part#: MB-P6080
Instruction Manual

Scigiene MB-P6080 Electronic Pipette Controller

Product Details

Scigiene MB-P6080 Electronic Pipette Controller - Product Details

The Electronic Pipette Controller is lightweight (180g) and designed to fit comfortably in either the right or left hand. The natural feel of the ergonomic body design, the computer balanced weight distribution and the low pressure fingertip control buttons…all combine to provide a more comfortable pipetting experience.

Features

  • Pipetting speed: 25ml in less than 5 seconds.
  • For glass and plastic pipettes from 0.1-100ml.
  • Approx. 8 hours of continuous pipetting.
  • Two modes: gravity draining & electric draining.
  • Battery pack: Lithium battery 2.4V/700mah.
  • Rechargeable

Specifications

Volume range0.1 – 100ml
Suction speed25ml<5s(6 grades)
Draining speedElectric (6 grades)/gravity
Charging timeOnly 2-3 hours
Filter membrane0.45μm hydrophobic filter membrane
Weight180g

Easy Data Processing
Two Drainage Modes
The mode can be freely selected during the draining process:
Gravity Draining Mode & Electric Draining Mode
(Note: Regardless of the method, the speed can be adjusted sensitively by finger pressure)

Scigiene MB-P6080 Electronic Pipette Controller - Draining Mode

Gravity drainage
Touch the draining button and press it slightly, the draining function at this time is acted on by its own weight, allowing the liquid to drain naturally.
Electric drainage
Further pressing the drain button will trigger the micro pump to speed up the drain

Hydrophobic Design

Membrane Protection
Adapt to 0.45μm hydrophobic filter membrane, hydrophobic high-temperature disinfection filter membrane to prevent damage to the equipment due to suction.

Scigiene MB-P6080 Electronic Pipette Controller - Membrane Protection

Precautions
When using pipettor do not over fill pipettes. If you do so fluids could enter pipettor and contaminate it. There is a hydrophobic filter inside that can be replaced but this can be blocked if you draw fluids into it.
When charging please charge pipettor until charged. Do not leave plugged in when not charging as this can decondition the battery.

Scigiene logo1295 Morningside Avenue, Unit 16-18
Scarborough, ON M1B 4Z4 Canada
Phone: 416-261-4865
Fax: 416-261-7879
www.scigiene.co

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.