50673 Shield Plus Fixed Downlight
Product Information:
| Product Name | ShieldPlus Fixed |
|---|---|
| Manufacturer | BH17 7BY (UK Manufacturer) Brilliant AG, Brilliantstrasse 1, D-27442 Gnarrenburg (EU Manufacturer) |
| Website | www.saxbylighting.com |
| Specification | Lamp: 1 x 50W Max. GU10 Mains Halogen IP Rating: 20 |
Product Usage Instructions:
Before using the product, please read the instructions carefully
to ensure safe and satisfactory operation. Retain these
instructions for future reference.
Safety Information:
- Always switch off the power supply before changing lightbulbs
or cleaning. - This is a Class 1 product and must be earthed.
- If replacing an existing fitting, make a careful note of the
connections. - Do not exceed the wattage stated.
- When changing a bulb, always switch off at the mains and allow
the old bulb to cool down before handling. Dispose of used bulbs
carefully and responsibly. - Ensure other persons cannot restore the electrical supply
without your knowledge.
Installation:
Before installation, completely remove any existing fittings.
Take note of the position of each set of wires before removing the
existing fitting. Ensure that the cables are long enough to connect
to the desired positions.
The distance between units must be no less than 0.5m (50cm).
For 50673/50674/61059/99758 models, use a 70mm diameter cutout
and a minimum ceiling void of 175mm.
For 50681/50682/61060/99759 models, use an 83mm diameter cutout
and a minimum ceiling void of 175mm.
Fit the recessed unit snugly into the hole. Make sure to remove
any roof void insulation from at least 150mm around the hole. Do
not cover the fittings with insulating matting or similar
material.
Wiring:
Refer to Diagram A and Diagram B for wiring instructions.
- Check that you have correctly identified the wires.
- Ensure the connections are tight.
- Make sure no loose strands have been left out of the connection
block.
Commissioning 1
· The ceiling surface must be flat and smooth to ensure a good fit.
· Push the spring clips upwards and fit the two arms into the ceiling hole.
· Push the unit up until firmly in position, ensuring that
the cable is not trapped.
· Adjust the cable so it does not get snagged.
2
· Adjust the light source of 50681/50682/61060/99759 to the desired angle.
· Replace fuse or circuit breaker and switch on. Your light is now ready for use.
Fitting/replacing the bulbs
· When changing a bulb, always switch off at the mains and allow the bulb to cool before handling. Dispose of used bulbs carefully. Use a soft cloth to handle bulbs, avoid directly touching the bulbs as this will shorten their life.
· Do not exceed the wattage stated or use a different shape bulb from that indicated on the fitting.
· Rotate the front bezel off, and drop down, Lift the bulb and slide out of the clip.
· To replace the bulb, slide into the clip, ensuring it is sitting properly on the recess.
50W GU10 Mains Halogen
Care and Cleaning
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
Recycling advice
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice.
Safety information
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
UK Manufacturer: BH17 7BY EU Manufacturer: Brilliant AG, Brilliantstrasse 1, D-27442 Gnarrenburg
www.saxbylighting.com
V8 13/11/2021 Saxby Lighting
Instruction leaflet
ShieldPlus
Fixed
50673, 50674, 61059, 99758
Titl
50681, 50682, 61060, 99759
Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
direct mounting on normally flammable surfaces (suitable only for mounting on non-combustible surfaces). Please read these instructions carefully before commencing any work.
electrician. Install in accordance with IEE Wiring regulations and
before installing or maintaining this fitting. Ensure other persons cannot restore the electrical supply without your knowledge.
If replacing an existing fitting, make a careful note of the connections.
exceed the wattage stated. When changing a bulb, always switch off at the mains and allow the old bulb to cool down before handling. Dispose of used bulbs carefully and responsibly.
verification of dimming abilities with the lamp manufacture prior to use. Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.
Specification
Lamp: IP rating:
220-240V ~ 50Hz All Models – 1 x 50W Max. GU10 Mains Halogen 20
Layout
This product has no special protection against the ingress of moisture.
This product is suitable for use in outside zones of a bathroom only. Please see diagram.
If this unit is being fitted in a room containing a bath or shower, a 30mA RCD must be used – in accordance with IEE regulations
2.25m Zone 1 0.6m Outside zones
Zone 2
0.6m
Zone 2
0.5m
(50cm) to the illuminated surface.
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.
that the cables are long enough to connect to the desired positions.
distance between units must be no less than 0.5m (50cm).
surface.
50673/50674/61059/99758 : 70mm diameter cutout; 175mm ceiling void (minimum) 50681/50682/61060/99759 : 83mm diameter cutout; 175mm ceiling void (minimum)
until the recessed unit fits snugly.
removing any roof void insulation from at least 150mm around the hole. Under no circumstances must these fittings be covered with insulating matting or similar material.
Wiring
Fit the terminal block box onto the bracket at the top of the product (see diagram A) and open the cover. Connect the incoming live and neutral cable to the terminals (use minimum 1.0mm2 core cable). Connect the live supply to the terminal marked 1 (brown wire) and neutral supply to the terminal marked N (blue wire) by simply pushing the lever on each terminal block and inserting the cable (see diagram B). Ensure connections are tight. An earth terminal and a spare terminal are provided for cable terminations where necessary. Replace the cover onto the terminal block case.
Diagram A
Diagram B
Check that…
You have correctly identified the wires. The connections are tight. No loose strands have been left out of the connection block.