WAN-H100V012T AC to DC LED Power Supply or LED Driver

Product Information

The WAN-H100V012T is a power supply unit manufactured by
Shenzhen LeadPower Technology Co., Ltd. It is designed for high
efficiency, low temperature rise, and high reliability. The unit
has an input voltage range of 176~264Vac and is equipped with a
built-in EMI filter to ensure lower ripple and low noise. It also
provides various protections such as over current protection, over
load protection, and short circuit protection.

Technical Specifications

No.ItemTechnical RequirementsUnit
1.1Rated Input Voltage200~240Vac
1.2Input Voltage Range176~264Vac
1.3Rated Frequency50/60Hz
1.4Frequency Range47~63Hz
1.5Max. Input Current1.5A
1.6Inrush Current60A
2.1Rated Output Voltage12Vdc
2.2Rated Output Current8.3A
2.3Max Output Power99.6W
2.4Efficiency86%
2.5Line Regulation
2.6Load Regulation
2.7Voltage Tolerance
2.8Ripple & Noise300mVp-p

Product Usage Instructions

  1. Ensure the input voltage is within the range of
    176~264Vac.
  2. Connect the three core input cable as follows:
    • Brown(L) – Live wire
    • Blue(N) – Neutral wire
    • Yellow-Green (G) – Ground wire
  3. Connect the two-core output cable to the desired device.
  4. Make sure the power supply is properly ventilated for
    cooling.
  5. Do not immerse the power supply in water for more than 0.5
    hours or bury it underground for use.
  6. Refer to the provided derating curve for specific operating
    conditions and load requirements.
  7. In case of over current, over load, or short circuit, the power
    supply will automatically recover after the fault condition is
    removed.
  8. Follow the specified working temperature range of -30~+70°C and
    storage temperature range of -40~+80°C.
  9. The power supply has a protection rating of IP67, which means
    it is protected against dust and temporary immersion in water.
  10. Ensure proper insulation resistance and leakage current
    according to the safety standards mentioned in the manual.

Shenzhen LeadPower Technology Co., Ltd https://www.leadpowers.com
Product Features
Input voltage range 176~264Vac; High efficiency, low temperature rise, high reliability; Built-in EMI filter, lower ripple & low noise; Protections: over current protection, over load protection, short circuit protection.

Model WAN-H100V012T

1

No.

Item

1.1 Rated Input Voltage

1.2 Input Voltage Range

1.3 Rated Frequency

1.4 Frequency Range

1.5 Max. Input Current

1.6 Inrush Current

2

No.

Item

2.1

Rated output voltage

2.2 Rated output current

2.3 Max Output power

2.4 Efficiency

2.5 Line regulation

2.6 Load regulation

2.7 Voltage tolerance

2.8

Ripple & Noise

Input

Technical Requirements

Unit

200~240

Vac

176j264

Vac

50/60

Hz

47~63

Hz

1.5

A

60

A

Output

Technical Requirements

Unit

12

Vdc

8.3

A

99.6

W

86%

±1%

±2%

±2%

300

mVp-p

Note
Refer to derating curve
Vin=190Vac, rated load 240Vac input, 25, cold start
Note
Refer to derating curve 25, 230Vac input, rated load
25, rated input, rated load, bandwidth of 20MHz, connected a 10uF electrolytic capacitor and a 0.1uF ceramic capacitor in parallel to the output terminals.

2.9
2.10 2.11 2.12 2.13
3 No. 3.1 3.2

Dynamic Response Overshoot 5 Dynamic Response Recovery Time 200

%

5%~50%~25%, 50%~75%~50 load dynamics,

half-wave period is 4mS, current change slope

us

is 0.1A/uS

Turn-on Delay Time

3

s

200~240Vac input, rated load

Output Voltage Rise Time

70

ms

200~240Vac input, rated load,25

Turn-on/off Overshoot

±10%

Protection

Item Over Current Protection Short Circuit Protection

Technical Requirements

Unit

Note

9.5j12

A

Hiccup model, recovers automatically after fault condition is removed

Long time short-circuit protection without damage, recovers automatically after fault condition is removed.

Page 1 of 3

Shenzhen LeadPower Technology Co., Ltd https://www.leadpowers.com

Model WAN-H100V012T

2. Environment

No.

Item

Specs

1

Working temperature range -30~ +70(Typ. 25)

2

Max case temperature

90

3

Storage temperature range -40~ +80(Typ. 25)

4

Relative humidity

20~95

5

Altitude

0~5000

6

Protection Rating

IP67

7

Cooling method

Ventilation cooling

Unit
% m

Note
Refer to derating curving Tc
No condensing
The power supply shall not be immersed in water for more than 0.5 hours (less than 1 meter in depth); It shall not be buried underground for use.

3. Reliability Requirement
MTBF100Khours Test condition: 25, rated input, rated load, MIL-HDBK-217F Notice 2

4. Safety standards

No.

Item

Dielectric

4.1.

Strength

(Hi-Pot)

I/P-O/P I/P-FG O/P-FG

4.2

Insulation Resistance

I/P-O/P I/P-FG O/P-FG

4.3

Leakage Current

4.4

Safety Standard

4.5

Electromagnetic Interference

Testing Condition

Note

3750Vac, 60S, current10mA 1750Vac, 60S, current10mA

No arcing,no breakdown

500Vac, 60S, current10mA

10M@ 500Vdc 10M@ 500Vdc

90% RH, 1 atm

10M@ 500Vdc 0.75mA

240Vac/60Hz

GB19510.1,.14/EN61347-1,-2-13/EN62384/UL8750/IP67

EN61547; EN61000-4-2,3,4,5,6,8,11; (surge immunity Line-Earth 4KV, Line-Line 2KV)

5. Mechanic Specification

5.1 Terminals (Unit: mm)

No. 5.1.1 5.1.2 5.1.3

Item Overall Dimension Three core input cable Two-core output cable

Parameters/mm 166(L)*51 (W)*28.5(H) Length:300mm Length:200mm

Note
Brown(L) Blue(N) Yellow-Green (G) Brown(V+) Blue(V-)
Page 2 of 3

Shenzhen LeadPower Technology Co., Ltd https://www.leadpowers.com
5.2 Dimension cUnitmm

Model WAN-H100V012T

Note: L1=300±5mmL2=200±5mmL3=30±2mmL4=30±2mmL5=5±1mm
6. Derating Curve
In order to ensure that the product can achieve the expected design service life, please configure the AC supply voltage and load of the power supply according to the derating requirements of the following curve. When the ambient temperature rises to a certain value, the output power also needs to be derated.