ID8W-WF LED Wifi Downlight
Smart WIFI Tuya User Manual
Certainty at The Speed of Light
Product Information
The Smart WIFI Tuya LED Downlight, ID8W-WF, is a high-quality
luminaire suitable for indoor use. It comes with a built-in driver
that allows for easy installation and maintenance. The luminaire is
rated IP54, making it suitable for indoor areas including bathrooms
and covered/sheltered areas such as porches.
Before installation, please check the IP label on the luminaire
to choose the right place to install. The luminaire is available in
three colour temperatures: WW: 3000K, NW: 4000K, and CW: 5700K. It
is also available with a colour changeable switch.
Important Safety Instructions
Basic safety precautions should always be followed when
installing, including the following:
- Read all instructions.
- Use a licensed electrician for installation only.
- Use IP54 rated luminaire for indoor use only.
- Always ensure the power is OFF and the fitting has cooled down
before performing any maintenance, cleaning, changing the globe or
adjustment to the fitting. - Do not install any luminaire near the heat source.
- Do not exceed the nominal supply voltage or amperage
ratings. - To avoid damage to the fitting, please ensure that power leads
and screws are secure before connecting the power.
Installation Instructions
The fitting has an insulating ceiling type IC-4 rating. Building
material and thermal insulation that can safely be exposed
continuously to temperatures up to 90 may abut and cover the
luminaire. If the building material cannot meet this condition, the
minimum clearance of 25mm is required.
Before installation, please check the information of driver as
below:
- Non-dim: Can not be used with any dimmer.
- Triac dim: Compliable with recommended TRIAC dimmers, dimming
range 8-100%.
Installation Spacing
See the table below for reference on ceiling cutout sizes:
| Downlight dia (inch) | Ceiling Cutout (mm) |
|---|---|
| 2.5 | 70-75 |
| 3 | 90 |
| 4 | 120 |
| 6 | 160 |
| 8 | 190 |
Product Usage Instructions
Please follow the instructions below to install and use the
Smart WIFI Tuya LED Downlight:
- Make sure to switch off power supply before starting any
installation. - Read instructions carefully and check that you have all the
tools and accessories needed to complete the installation
correctly. - Select the desired colour temperature before installation. This
can be WW: 3000K, NW: 4000K, or CW: 5700K. - For downlights with an internal driver, use a screwdriver to
open the driver terminal cover on the back of the downlight. Feed
the main AC wire L. N. in the terminal block respectively, then fix
the cover back. - Hold back the spring clip and push the downlight into the
hole. - Make sure the downlight is fixed tightly in the ceiling.
- Turn on the power.
Note that if you have a colour changeable switch, follow these
additional steps:
- Cut a hole according to the cutout size of the LED
downlight. - Use a screwdriver to open the driver terminal cover on the back
of the downlight. Feed the main AC wire L. N. in the terminal block
respectively, then fix the cover back. - Connect the colour changeable switch according to its
instructions. - Hold back the spring clip and push the downlight into the
hole. - Make sure the downlight is fixed tightly in the ceiling.
- Turn on the power.
Please note that only a professional electrician should install
and maintain this product. Follow all safety precautions and do not
install any luminaire near a heat source or exceed nominal supply
voltage or amperage ratings.
Smart WIFI Tuya User Manual
Certainty at The Speed of Light
LED WIFI
ID8W-WF
Important Safety Instructions
Basic safety precautions should always be followed when installing, including the following: 1. Read all instructions. 2. Licensed electrician for installation only. 3. IP54 for indoor use only. 4. Always ensure the power is OFF and the fitting has cooled down before performing
any maintenance, cleaning, changing the globe or adjustment to the fitting.
5. Do not install any luminaire near the heat source. 6. Do not exceed the nominal supply voltage or amperage ratings. 7. To avoid damage to the fitting, please ensure that power leads and screws are secure
before connecting the power.
Installation Instructions
The fitting has an insulating ceiling type IC-4 rating. Building material and thermal insulation that can safely be exposed continuously to temperatures up to 90 may abut and cover the luminaire. If the building material cannot meet this condition, the minimum clearance of 25mm is required. See Figure 1
Fig 1: Installation Spacing
Thermal insulation
HCB=25mm
Building material
SCB=25mm
Tab 1: Ceiling cutout reference table.
Downlight dia (inch)
2.5
3
4
6
8
Ceiling Cutout (mm)
70-75
90
120
160
190
NOTE: Before installation, please check the IP label on the luminaire to choose the right place to install.
IP20/IP40 Indoor use only, do not use in wet or damp place.
IP44/IP54
Suitable for indoor areas including bathrooms and covered/sheltered areas such as porches.
IP65
Suitable for outdoor areas, not suitable for water immersion.
NOTE: Before installation, please check the information of driver as below.
Non-dim
Can not be used with any dimmer.
Triac dim
Compliable with recommended TRIAC dimmers, dimming range 8-100%.
Installation Procedure
WARNING
1.Switch off before installation. 2.Switch on only after complete installation and examination of the circuit. 3.Professional electrician for installation and maintenance only. 4.Risk of overheating of fire if the clearance distances are compromised.
Turn Off power supply before starting any installation. Read instructions & check you have all the tools & accessories to complete the installation correctly.
Downlight with internal driver
Please select the colour temperature before installation: WW: 3000K NW: 4000K CW: 5700K
Colour changeable switch
1. Cut a hole according
to the cutout size of led downlight.
2. Use screw-driver to open the
driver terminal cover on the back of downlight, feed the main AC wire L. N. in terminal block respectively, then fix the cover back.
3. Hold back the spring clip then push the downlight into the hole.
RISK OF FIRE Required clearance from structural members and building elements SCB=25mm HCB=25mm
Warning:
Input wire diameter 0.75mm² Product modification and improper installation void the warranty!
4. Make sure the downlight
fixed tightly in ceiling, turn on the power (Fig 1).















