PCE-T312N Digital Thermometer
Product Information:
The Thermometer PCE-T312N is a contact thermometer designed for
measuring temperature using thermocouple sensors. It has a
user-friendly interface with a display that shows various icons and
measurements. The thermometer comes with two TF-500 Thermo-wire
sensors and operates on three 1.5V AAA batteries.
Safety Notes:
Before using the device, it is important to read the user manual
carefully. The device should only be used by qualified personnel
and repaired by PCE Instruments personnel. Non-observance of the
manual may result in damage or injuries, which are not covered by
the warranty.
Delivery Contents:
- 1 x Thermometer PCE-T312N
- 2 x TF-500 Thermo-wire sensor
- 3 x 1.5V AAA batteries
- 1 x User manual
Specifications:
The specifications of the Thermometer PCE-T312N are not provided
in the given text extract.
Display Description:
- Setup icon
- Offset icon
- Hold icon
- Auto-Off icon
- Primary display
- Units
- Secondary display
- MAX, MIN, AVG display
- Measurement period
- Time units
- Type of thermocouple
- Battery level indicator
Key Description:
- Power On/Off: Turns the meter on/off.
- Hold: Press once to hold the reading, press again to continue
measurement. In settings, used for menu selection and parameter
changes. - MIN/MAX/AVG: In measuring mode, select between minimum,
maximum, and average values. In settings, used for menu selection
and parameter changes. - Backlight: Press once to activate backlight, press again to
deactivate. In settings, press and hold for three seconds to
enter/exit settings.
Settings:
To enter the settings, press and hold the Backlight key for
three seconds. To leave the settings, press and hold the Backlight
key again for three seconds. Use the arrow keys at the side of the
meter to select a menu item or change parameters. Press the Menu
key to confirm a change or open a menu item.
Possible Display Settings:
- Type of thermocouple: K and J
- Offset: ON and OFF
Note:
The menu cannot be accessed while the MIN MAX AVG function is
activated.
Usage Instructions – Change Type of Thermocouple:
To change the type of thermocouple being used by the
thermometer, follow these steps:
- Make sure the thermometer is turned on.
- Press and hold the Backlight key for three seconds to enter the
settings. - Use the arrow keys to navigate to the “Type” setting.
- Press the Menu key to select the “Type” setting.
- Use the arrow keys to toggle between the available thermocouple
types (K and J). - Press the Menu key to confirm the selection.
- Press and hold the Backlight key for three seconds to exit the
settings.
Note: The thermocouple type can only be changed when the MIN MAX
AVG function is not activated.
English
User Manual
Thermometer PCE-T312N
User manuals in various languages (français, italiano, español, português, nederlands, türk, polski,
, ) can be found by using our product search on: www.pce-instruments.com
Last change: 22 October 2019 v1.0
© PCE Instruments
Contents 1 Safety notes ………………………………………………………………………………. 1 2 Delivery contents ………………………………………………………………………. 2 3 Specifications ……………………………………………………………………………. 2 4 Display description ……………………………………………………………………. 3 5 Key description …………………………………………………………………………. 4 6 Settings …………………………………………………………………………………….. 4
6.1 Change type of thermocouple ……………………………………………………………………………… 4 6.2 Set offset………………………………………………………………………………………………………….. 5 6.3 Automatic Power Off ………………………………………………………………………………………….. 5
7 Thermocouples …………………………………………………………………………. 5 8 Hold reading ……………………………………………………………………………… 5 9 MIN / MAX / AVG ………………………………………………………………………… 6 10 Replacing the batteries ……………………………………………………………… 6 11 Contact……………………………………………………………………………………. 7 12 Disposal ……………………………………………………………………………………. 7
© PCE Instruments
1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
· The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
· The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
· Do not expose the device to shocks or strong vibrations. · The case should only be opened by qualified PCE Instruments personnel. · Never use the instrument when your hands are wet. · You must not make any technical changes to the device. · The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents. · The device must only be used with accessories from PCE Instruments or equivalent. · Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device. · Do not use the instrument in explosive atmospheres. · The measurement range as stated in the specifications must not be exceeded under
any circumstances. · Non-observance of the safety notes can cause damage to the device and injuries to
the user. We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.
© PCE Instruments 1
2 Delivery contents
1 x Contact Thermometer PCE-T312N 2 x TF-500 Thermo-wire sensor 3 x 1.5V AAA batteries 1 x User manual
3 Specifications
Thermocouple types Measuring range thermocouple Type K Measuring range thermocouple Type J Measurement units Display Display functions Power supply Automatic shutdown Temperature accuracy over 100ºC (148ºF) Temperature accuracy under 100ºC (148ºF) Temperature accuracy T1-T2 Operating temperature Storage temperature
Type K and Type J -200 … 1372°C / -328 … 2501°F -210 … 1100°C / -346 … 2012°F °C / °F / K Large, dual LCD with backlight T1, T2, T1-T2, MAX, MIN, AVG 3 x 1.5V AAA batteries After 20 minutes of inactivity ± [0.15% rh +1°C (1.8°F)] ± [0.5% rh +2°C (3.6°F)] ± [0.5% rh +1°C (1.8°F)] 0 … 50°C (4 … 122°F) 10 … 50°C (14 … 122°F)
© PCE Instruments 2
4 Display description
No. Short description 1 “Setup” icon 2 “Offset” icon 3 “Hold” icon 4 “Auto-Off” icon 5 Primary display
6 Units 7 Secundary display
8 MAX, MIN, AVG display
9 Measurement period 10 Time units
11 Type of thermocouple 12 Battery level indicator
Long description Shows that you are in the menu
Shows that the reading has been held Shows that the meter will turn off automatically Shows the reading of T1, T2 as well as the difference between T1 and T2 Shows the unit (°C, °F, K) Shows the following functions: MAX, MIN, AVG, Offset, T1 and T2 Shows what function is shown in the secondary display
Shows the measurement period Shows if hours and minutes or minutes and seconds are displayed in the field for the measurement period Shows the set type of thermocouple Shows that the batteries are flat and must be replaced
© PCE Instruments 3
5 Key description
Key Description Turns the meter on/off
When you are in the settings screen, you can open a menu item and confirm the set value with this key. Changes what is shown on the primary and secondary display. Options: T1, T2 and T1-T2 Changes the unit. Options: °C, °F and K
By pressing this key once in the measuring screen, the reading will be held. By pressing the key again, the measurement will be continued. In the settings, this key can be used to select a menu item and parameters within a menu can be changed.
By pressing this key in measuring mode, you can select between MIN, MAX and AVG. In the settings, this key can be used to select a menu item and parameters within a menu can be changed.
By pressing this key once, the backlight is activated. By pressing the key again, the backlight is deactivated. To enter the settings, press and hold this key for three seconds. To leave the settings, press and hold this key again for three seconds.
6 Settings
To enter the settings, press and hold the key for three seconds. To leave the settings, press
and hold the key again for three seconds. To select a menu item or to change parameters within the menu items, use the arrow keys at the side of the meter. To confirm a change or to
open a menu item, press the Menu Set type of thermocouple Offset Auto Off
key. The settings are arranged as follows:
Display
Possible settings
TYPE
K and J
OFFSET Range ±5.0 °C / ±9.0 °F
SLP
ON and OFF
Note: As long as the MIN MAX AVG function is activated, you cannot enter the menu.
6.1 Change type of thermocouple
If the connected type of thermocouple is different from the type shown in the lower left-hand side of the display, the meter’s thermocouple setting must be changed accordingly. To do so, enter settings mode and change the type as required. Thermocouples of the types K and J can be connected.
© PCE Instruments 4
6.2 Set offset
When the accuracy is outside the specifications, an offset can be carried out. The possible range for the offset is ±5.0 °C / ±9.0 °F. To be able to set the offset, first connect the meter to the thermocouples. Then place the thermocouples into a liquid of known temperature, for instance ice water. Now wait for the displayed reading to stabilise. Then go to the settings and change the offset until the displayed reading equals the value of the reference liquid. Offsets must be set for each channel individually.
6.3 Automatic Power Off
The meter has an automatic power off function. This means that the meter turns off automatically after 20 minutes of inactivity. To disable this function temporarily, enter the settings. In the menu item “SLP”, you can disable this function. ON = enabled, OFF = diabled Note: Everytime the meter is powered on, this function will be enabled automatically.
7 Thermocouples
If you want to use thermocouples, connect these via the connectors at the upper side of the meter. Observe correct polarity. Now power on the meter. After approx. a second, a reading will be displayed. If no thermocouple is attached for a channel, “- – – -“ will be displayed. When the reading is exceeded, “OL” will be displayed.
With the key, you can select T1, T2 or T1 T2 to be shown in the primary or secondary display. Note: Ensure that you have set the correct type of thermocouple. The type of thermocouple can be changed in the settings. The current thermocouple is shown in the lower left-hand part of the display.
8 Hold reading
To hold the currently displayed reading, press the key during the measurement. “HOLD” will
be displayed. While “HOLD” is displayed, the
key will be active. To continue the
measurement, press the key again.
© PCE Instruments 5
9 MIN / MAX / AVG
The temperature meter has the following measuring functions:
Name Description
MIN
Shows the lowest reading
MAX
Shows the highest reading
AVG
Shows the average value
To activate one of these functions, press the key. “REC” will appear in the display along with the function you set. The current reading will only be shown in the primary display now. In the secondary display, the respective value of the measuring function will be displayed. At the same time, the measurement period will start, which will show you when the value has been determined. You can switch between the different measuring functions at any time. All values are determined
continuously. To leave this function, press and hold the key for three seconds. Note: After leaving this measuring function or when the meter is turned off, the saved readings will be lost.
10 Replacing the batteries
As soon as the battery icon appears in the display, the batteries must be replaced to make sure the meter works in line with its specifications. To replace the batteries, first turn off the meter. Then open the battery compartment at the rear side. Replace the batteries by three new 1.5 V AAA batteries, observing correct polarity. The meter is ready to be used again after closing the battery compartment.
© PCE Instruments 6
11 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
12 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.
© PCE Instruments 7
PCE Instruments contact information
Germany
PCE Deutschland GmbH Im Langel 4 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 [email protected] www.pce-instruments.com/deutsch
Germany
PCE Produktions- und Entwicklungsgesellschaft mbH Im Langel 26 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 471 Fax: +49 (0) 2903 976 99 9971 [email protected] www.pce-instruments.com/deutsch
The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 [email protected] www.pce-instruments.com/dutch
United States of America
PCE Americas Inc. 711 Commerce Way suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 [email protected] www.pce-instruments.com/us
France
PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 [email protected] www.pce-instruments.com/french
United Kingdom
PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 [email protected] www.pce-instruments.com/english
China
PCE (Beijing) Technology Co., Limited 1519 Room, 6 Building Zhong Ang Times Plaza No. 9 Mentougou Road, Tou Gou District 102300 Beijing, China Tel: +86 (10) 8893 9660 [email protected] www.pce-instruments.cn
Turkey
PCE Teknik Cihazlari Ltd.ti. Halkali Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece – stanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 [email protected] www.pce-instruments.com/turkish
Spain
PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 [email protected] www.pce-instruments.com/espanol
Italy
PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 [email protected] www.pce-instruments.com/italiano
Hong Kong
PCE Instruments HK Ltd. Unit J, 21/F., COS Centre 56 Tsun Yip Street Kwun Tong Kowloon, Hong Kong Tel: +852-301-84912 [email protected] www.pce-instruments.cn
© PCE Instruments 8
References
France.fr : Actualités, destinations et infos du tourisme en France
iberica.es
Make an offer on the domain instruments.co.uk - Domains.co.uk
Computer Instruments | Home
Discover Italy: Official Tourism Website - Italia.it
PCE(北京)科技有é™å…¬å¸
Industrial Measurement Products and Solutions | PCE Instruments
PCE Deutschland GmbH Prüfgeräte vom Hersteller | PCE Instruments
PCE Brookhuis B.V. | PCE Instruments
PCE Americas Inc. : Test Instruments | PCE Instruments
PCE Iberica S.L. Instrumentación | PCE Instruments
PCE Instruments France | PCE Instruments
PCE Italia s.r.l. / Strumenti di Misura | PCE Instruments
PCE Teknik Cihazlar Paz. Tic. Ltd.Şti. | PCE Instruments
PCE Americas Inc. : Test Instruments | PCE Instruments
PCE Americas Inc. : Test Instruments | PCE Instruments