Pce Instruments Pce-ht 112 Data Logger Temperature User Manual

PCE-HT 112 Data Logger Temperature

Product Information:

PCE-HT 112 & PCE-HT 114 Data Logger

The PCE-HT 112 and PCE-HT 114 are data loggers designed for
measuring and recording temperature. They are equipped with an LC
display, start/stop key, display time switch, external sensor
connections, and a reset key/mounting tab. The data loggers are
used to monitor temperature fluctuations during the storage or
transport of pharmaceuticals.

Technical Specifications:

PCE-HT 112:

  • Display: LC display
  • External Sensor Connections: 1

PCE-HT 114:

  • Display: LC display
  • External Sensor Connections: 4

Operating Instructions:

  1. Read the user manual carefully before using the device for the
    first time.
  2. The device should only be used by qualified personnel.
  3. Ensure that any repairs are carried out by PCE Instruments
    personnel.
  4. Press the start/stop key to begin or end data recording.
  5. Use the display time switch to show data on the display.
  6. Connect the external sensor(s) to the corresponding sensor
    connection(s) on the backside of the device.
  7. Press the reset key/mounting tab to reset the device.

Hints:

  • For models with multiple external sensor connections, the
    connections may vary. Refer to the specific model’s documentation
    for details.
  • Certain icons may or may not be displayed depending on the
    model.

Contact and Disposal:

If you have any questions or need assistance, please contact PCE
Instruments using the contact details provided at the end of the
user manual.

For disposal instructions, refer to the disposal section at the
end of the user manual.

Englis h

User Manual
PCE-HT 112 & PCE-HT 114 Data Logger
User manuals in various languages (français, italiano, español, português, nederlands, türk, polski,
, ) can be found by using our product search on: www.pce-instruments.com
Last change: 24 August 2020 v1.0
© PCE Instruments

Contents 1 Safety notes ………………………………………………………………………………. 1 2 Device description …………………………………………………………………….. 2
2.1 Front page………………………………………………………………………………………………………… 2 2.2 Backside ………………………………………………………………………………………………………….. 2 2.3 Display …………………………………………………………………………………………………………….. 3
3 Technical specifications ……………………………………………………………. 4
3.1 Technical data PCE-HT 112………………………………………………………………………………… 4 3.2 Technical data PCE-HT 114………………………………………………………………………………… 5
4 Operating instructions ………………………………………………………………. 6
4.1 Switch on the device ………………………………………………………………………………………….. 6 4.2 Switch off the device ………………………………………………………………………………………….. 6 4.3 Switch on the display………………………………………………………………………………………….. 6 4.4 Switch off the display………………………………………………………………………………………….. 6 4.5 Switching the time / date …………………………………………………………………………………….. 6 4.6 Start data recording……………………………………………………………………………………………. 6 4.7 Stop data recording……………………………………………………………………………………………. 6 4.8 Display minimum, maximum and average measured value ………………………………………. 6 4.9 Deactivate the audible alarm ……………………………………………………………………………….. 6 4.10 Set markers………………………………………………………………………………………………………. 7 4.11 Read out data …………………………………………………………………………………………………… 7
5 Hints …………………………………………………………………………………………. 7
5.1 External sensor …………………………………………………………………………………………………. 7 5.2 Battery …………………………………………………………………………………………………………….. 7
6 Contact……………………………………………………………………………………. 7 7 Disposal ……………………………………………………………………………………. 7
© PCE Instruments

1 Safety notes
Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.
· The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
· The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
· Do not expose the device to shocks or strong vibrations. · The case should only be opened by qualified PCE Instruments personnel. · Never use the instrument when your hands are wet. · You must not make any technical changes to the device. · The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents. · The device must only be used with accessories from PCE Instruments or equivalent. · Before each use, inspect the case for visible damage. If any damage is visible, do not
use the device. · Do not use the instrument in explosive atmospheres. · The measurement range as stated in the specifications must not be exceeded under
any circumstances. · Non-observance of the safety notes can cause damage to the device and injuries to
the user. We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.
© PCE Instruments 1

2 Device description
2.1 Front page 1.: LC display 2.: Start/stop key / display time 3.: Switch display on/off / show data / mark
2.2 Backside 4: External sensor connection 1 5: External sensor connection 2 6: External sensor connection 3 7: External sensor connection 4 8: Reset key / mounting tab
Note: The connections for external sensors may vary depending on the model.
© PCE Instruments 2

2.3 Display 1.: Channel number 2.: Alarm exceeded 3.: Alarm display 4.: Alarm underrun 5.: Factory reset 6.: External sensor connected 7.: Recording 8.: USB connected 9.: Data logger is being charged 10.: Radio connection active (depending on model) 11.: Air quality indicator 12.: Marker 13.: Time 14.: Percentage symbol 15.: Clock symbol 16.: Memory symbol 17.: Td: dew point 18.: Lower measured value display 19.: Temperature or humidity symbol 20.: Waiting symbol 21.: MKT: mean kinetic temperature1 22.: Time unit 23.: Upper measured value display 24.: House symbol 25.: Display symbol 26.: Settings symbol 27.: MIN / MAX / average display 28.: Warning symbol 29.: Buzzer symbol 30.: Backlight 31.: Keys locked 32.: Battery status display
Note: Certain icons may or may not be displayed depending on the model.
1 The “mean kinetic temperature” is a simplified way to determine the overall influence of temperature fluctuations during the storage or transport of pharmaceuticals. The MKT can be regarded as an isothermal storage temperature that simulates the non-isothermal effects of changes in the storage temperature. Source: MHRA GDP
© PCE Instruments 3

3 Technical specifications

3.1 Technical data PCE-HT 112

Parameters Measurement range
Accuracy Resolution Response time

Temperature
-30 … 65 °C / -22 … 149 °F (internal) -40 … 125 °C / -40 … 257 °F (external) ±0.3 °C / 0.54 °F (-10 … 65 °C / 14 … 149 °F) ±0.5 °C / 0.9 °F (remaining range) 0.1 °C / 0.18 °F
15 min (internal) 5 min (external)

Relative humidity
0 … 100 % RH (internal) 0 … 100 % RH (external)
±3 % (10 % … 90 %) ±4 % (remaining range) 0.1 % RH

Memory
Storage rates
Measuring interval / display refresh rate Alarm Interface

25920 measured values 30 s, 60 s, 2 min, 5 min, 10 min, 15 min, 20 min, 25 min, 30 min, 1 h or individually adjustable
5 s
adjustable audible alarm USB

Power supply

3 x 1.5 V AAA batteries 5 V USB

Battery life Operating conditions Storage conditions

approx. 1 year (without backlight / without alarm) -30 … 65 °C / -22 … 149 °F -30 … 65 °C / -22 … 149 °F (without battery)

Dimensions Weight

96 x 108 x 20 mm / 3.8 x 4.3 x 0.8 in 120 g

Protection class

IP20

3.1.1 Scope of delivery PCE-HT 112
1 x data logger PCE-HT112 3 x 1.5 V AAA battery 1 x fixing set (dowel & screw) 1 x micro USB cable 1 x software on CD 1 x user manual

3.1.2 Accessories PROBE-PCE-HT 11X

external probe

© PCE Instruments 4

3.2 Technical data PCE-HT 114

Parameters Measurement range
Accuracy
Resolution Response time

Temperature
-40 … 125 °C / -40 … 257 °F (external) ±0.3 °C / 0.54 °F (-10 … 65 °C / 14 … 149 °F) ±0.5 °C / 0.9 °F (remaining range) 0.1 °C / 0.18°F
5 min

Relative humidity 0 … 100 % RH (external)
±3 % (10 % … 90 %) ±4 % (remaining range) 0.1 % RH

Memory
Storage rates
Measuring interval / display refresh rate Alarm Interface

25920 measured values 30 s, 60 s, 2 min, 5 min, 10 min, 15 min, 20 min, 25 min, 30 min, 1 h or individually adjustable
5 s
adjustable audible alarm USB

Power supply

3 x 1.5 V AAA batteries 5 V USB

Battery life Operating conditions Storage conditions

approx. 1 year (without backlight / without alarm) -30 … 65 °C / -22 … 149 °F -30 … 65 °C / -22 … 149 °F (without battery)

Dimensions

96 x 108 x 20 mm / 3.8 x 4.3 x 0.8 in

Weight Protection class

120 g / <1 lb IP20

3.2.1 Scope of delivery PCE-HT 114
1 x refrigerator thermo hygrometer PCE-HT 114 1 x external sensor 3 x 1.5 V AAA battery 1 x fixing set (dowel & screw) 1 x micro USB cable 1 x software on CD 1 x user manual

3.2.2 Accessories PROBE-PCE-HT 11X

external probe

© PCE Instruments 5

4 Operating instructions
If no key is pressed within 15 seconds, the automatic key lock is activated. Press the key for three seconds to make operation possible again.
4.1 Switch on the device The data logger switches on as soon as batteries are inserted into the device.
4.2 Switch off the device The data logger is permanently switched on and switches off as soon as the batteries are no longer sufficiently charged to ensure proper operation.
4.3 Switch on the display Press the key for three seconds and the display switches on.
4.4 Switch off the display Press the key for three seconds and the display switches off.

Note: The display cannot be turned off when it shows REC or MK.

4.5 Switching the time / date Press the key to switch between date, time and marker view.

4.6 Start data recording Press the key for three seconds to start data recording.

4.7 Stop data recording
If the software has been set to stop recording, press the key for three seconds to stop recording. Furthermore, recording stops when the memory is full or the batteries are no longer sufficiently charged to ensure proper operation.

4.8 Display minimum, maximum and average measured value As soon as one or more measured values have been saved to the memory of the data logger, it

is possible to display the MIN, MAX and average measured values by pressing the key.

If no measured values are recorded, the alarm limits.

key can be used to display the upper and lower

4.9 Deactivate the audible alarm
As soon as an alarm is triggered and the meter beeps, the alarm can be acknowledged by pressing one of the two keys.

© PCE Instruments 6

4.10 Set markers Once the meter is in recording mode, you can switch to marker view by pressing the key. To set a marker, press the key for three seconds to save a marker in the current recording. A maximum of three markers can be set. 4.11 Read out data To read out data from the data logger, connect the measuring instrument to the PC and start the software. When the instrument is connected to the computer, the USB icon appears on the display.
5 Hints
5.1 External sensor If the external sensor was not recognized, it may have been deactivated in the software. First activate the external sensor in the software. 5.2 Battery When the battery icon flashes or the display shows OFF, this indicates that the batteries are low and need to be replaced.
6 Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.
7 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.
© PCE Instruments 7

PCE Instruments contact information

Germany
PCE Deutschland GmbH Im Langel 4 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 [email protected] www.pce-instruments.com/deutsch
United Kingdom
PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 [email protected] www.pce-instruments.com/english
The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 [email protected] www.pce-instruments.com/dutch
United States of America
PCE Americas Inc. 711 Commerce Way suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 [email protected] www.pce-instruments.com/us

France
PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 [email protected] www.pce-instruments.com/french
Italy
PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 [email protected] www.pce-instruments.com/italiano
China
PCE (Beijing) Technology Co., Limited 1519 Room, 6 Building Zhong Ang Times Plaza No. 9 Mentougou Road, Tou Gou District 102300 Beijing, China Tel: +86 (10) 8893 9660 [email protected] www.pce-instruments.cn

Spain
PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 [email protected] www.pce-instruments.com/espanol
Turkey
PCE Teknik Cihazlari Ltd.ti. Halkali Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece – stanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 [email protected] www.pce-instruments.com/turkish
Hong Kong
PCE Instruments HK Ltd. Unit J, 21/F., COS Centre 56 Tsun Yip Street Kwun Tong Kowloon, Hong Kong Tel: +852-301-84912 [email protected] www.pce-instruments.cn

© PCE Instruments 8

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals