Product Information:
Product Name: AlphaBNWAS
Product Type: Bridge Navigational Watch Alarm
System
Manufacturer: pronav.no
Product Category: >150 GT Workboats,
Deepsea, Fishing Yachting
Features:
- Integrate in design
- Available in standard- and MF line version
- Approved system by Bureau Veritas MED
- Mandatory on SOLAS vessels of 150GT and up and passenger
vessels
Product Usage Instructions:
Alarm Stages:
1st stage alarm:
- A visual indication inside the main unit will be activated
after the dormant period ends. - If not reset within 15 seconds of the visual indication, an
audible alarm is sounded. - The alarm can be reset on the main unit, remote reset button,
or with a motion sensor. - If the alarm is not reset within 30 seconds, the second stage
alarm will sound.
2nd stage alarm:
- If the audible alarm from the first stage is not reset, another
audible alarm is sounded in the backup officer’s and/or Master’s
cabin. - This can be done using the officer’s selector switch (optional)
that can connect up to 6 different officers cabin units.
3rd stage alarm:
- If the audible alarm from the second stage is not reset,
another unique audible alarm with sufficient volume is sounded at
the locations of crew members capable of taking corrective
actions. - If the officer does not reset within 3 minutes, the 3rd stage
alarm will sound all over the vessel.
Specifications:
Main unit:
- Power supply: Input – 18-28 VDC@180mA max, Output – Reset 4
potential free - Mounting: Standard flush mount, Standard wall mount
- Protection: Set-up is protected by key-switch
- Dimensions: Standard version – 72x144x88 (WxHxD); Cut out:
67×139 (WxH), MF line version – 96x180x76 (WxHxD); Cut out: 90×160
(WxH)
Buzzer Unit:
- Power supply: 18-33 VDC@30mA max
- Dimensions: Standard flush mount – 72x96x70mm (WxHxD); Cut out:
67×91 (WxH), Standard wall mount – 96x180x76 (WxHxD); Cut out:
90×160 (WxH)
Reset Unit:
- Power supply: Standard – 18-28 VDC@10mA max, MF line –
18-30VDC@150mA - Dimensions: Standard – 72x144x70mm (WxHxD); Cut out: 139×67 mm
(WxH), MF line – 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
Selector Switch:
- Power supply: Standard – 18-33 VDC@30mA max, MF line – Modbus
interface (RS485) - Dimensions: Standard – 96 mm (3.78 in), MF line – 75.5 mm (2.97
in)
AlphaBNWAS
Bridge Navigational Watch Alarm System
· Compact design to fit in any existing console · Easy to install and operate · Set-up is protected by key-switch · Extendible with other alarm with Alarm Unit
pronav.no
Category >150 GT Workboats
Deepsea
Fishing Yachting
Features
A Bridge Navigational Watch Alarm System (BNWAS) is an aid to help protect the Ship’s Officers required to ensure a presence of the Officer of the Watch on the bridge and to carry out one man bridge duties. A BNWAS monitors bridge activity and detects any absence on the bridge that could lead to shipping accidents. The BNWAS system monitors the awareness of the Officer of the Watch (OOW) and warns the Master and/or another qualified Officer if the Officer of the Watch becomes incapable of performing duties through whatever cause.
· Cost effective design · Operator friendly · IMO approved · Flexible configuaration · Uniform product philosphy
· Extendable by means of extra reset buttons · Reports to the officer’s cabins · Dimming function · Possibility to switch on automatically with the autopilot · Communication interface to VDR and ECDIS (NMEA)
Integrate in design
The AlphaBNWAS is available in standard- and MF line version. When the AlphaBNWAS system is implemented into an Alphabridge design, a separate version of the control unit will be available with a modified front panel to comply with the recognizable corporate Alphabridge black or grey style.
Approved system
Ship owners can now meet these requirements in a cost effective way by choosing the Alphatron Watch Alarm system called the AlphaBNWAS. The AlphaBNWAS is a Bureau Veritas MED certified Bridge Navigational Watch Alarm System mandatory on SOLAS vessels of 150GT and up and passenger vessels irrespective of the size of the vessel.
Alarm stages
1st stage alarm
Once the dormant period ends, a visual indication inside the main unit will be activated. If not reset within 15 seconds of the visual indication, an audible alarm is sounded. This main unit is on the bridge and warns the person on watch he should reset the alarm. The alarm can be reset on the main unit or on the remote reset button or with a motion sensor. If the person on watch does not reset the alarm within 30 seconds the second stage alarm will sound.
2nd stage alarm
If at the first stage the audible alarm is not reset, 15 seconds after the audible alarm, another audible alarm is sounded in the backup officer’s and/or Master’s cabin. This can also be done by using the officer’s selector switch (optional), that can connect up to 6 different officers cabin units.
3rd stage alarm
If at the second stage the audible alarm is not reset, 90 seconds after it, another unique audible alarm with sufficient volume is sounded at the locations of further crew members capable of taking corrective actions. If the officer does not reset within 3 minutes the 3rd stage alarm will sound all over the vessel.
· Except for passenger’s vessels, the second and third stage alarm can be combined to sound at all locations. If this is applied, the third stage alarm may be omitted.
· For very large vessels, sufficient time of up to 3 minutes must be accounted for the backup officer or the Master to the reach the Bridge to tend to the situation.
Specifications
Tech Specs
Main unit Power supply Input Output Mounting Protection Dimensions Standard version MF line version
Buzzer Unit Power supply Dimensions Standard flush mount
Standard wall mount MF line version
Reset Unit Power supply Dimensions Standard MF line
Selector Switch Power supply Dimensions Standard
MF line
18-28 VDC@180mA max Reset 4 potential free Flush mount Set-up is protected by key-switch
72x144x88 (WxHxD); Cut out: 67×139 (WxH) 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
Main unit G-002351
180 mm (7.09 in)
18-33 VDC@30mA max
72x96x70mm (WxHxD) Cut out: 67×91 (WxH) 80x105x28mm (WxHxD) 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
96 mm (3.78 in)
96.8 mm (3.81 in)
Buzzer Unit G-002369
180 mm (7.09 in)
18-33 VDC@30mA max
72x96x70mm (WxHxD); Cut out: 67×91 (WxH) 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
18-28 VDC@10mA max
72x144x70mm (WxHxD) Cut out: 139×67 mm (WxH) 96x180x76 (WxHxD); Cut out: 90×160 (WxH)
96 mm (3.78 in)
75.5 mm (2.97 in)
Reset Unit G-002368
10 Channel Alarm Unit Power supply Interface Input (digital) Output Input Alarm relay Dimensions Standard
Horn Power supply Operating Temp Frequency Dimensions Standard
PIR Sensor Specifics Dimensions Standard
18-30VDC@150mA Modbus interface (RS485) 10 digital inputs (NO/NC) 3 group outputs 3 lock inputs Potential free alarm relay
72x144x75mm (WxHxD); Cut out: 139×67 mm (WxH)
8-35VDC -25°C to + 70°C / IP65 400-2850Hz
98x104mm (RxH)
110° angle and 360° overview
59x107x39mm (WxHxD)
180 mm (7.09 in)
96 mm (3.78 in)
75.5 mm (2.97 in)
Selector Switch G-002370
180 mm (7.09 in)
96 mm (3.78 in)
67.5 mm 2.66 in) 105 mm (4.13 in)
In the box
AlphaBNWAS MF Line
· AlphaBNWAS Main unit -Alpha MF line · AlphaBNWAS Reset unit -Alpha MF line · AlphaBNWAS cabin unit buzzer -Alpha MF line · AlphaBNWAS selector -Alpha MF line
G-002362 G-002365 G-002366 G-002367
AlphaBNWAS
· AlphaBNWAS Main Unit watch alarm, flush mount LR approved · AlphaBNWAS cabin unit buzzer, flush mount · AlphaBNWAS cabin unit buzzer, wall mount · AlphaBNWAS reset button · AlphaBNWAS selector switch · AlphaBNWAS outdoor wing remote reset
Accessories
· AlphaBNWAS 10 Channel Alarm Unit · AlphaBNWAS Alarm horn · AlphaBNWAS connectionbox · AlphaBNWAS Flush mount bracket for Buzzer-and reset unit mounting · AlphaBNWAS wall mounting box · AlphaBNWAS Flush mount bracket for main-unit mounting · AlphaBNWAS NMEA activation unit · AlphaBNWAS Main connection board · AlphaBNWAS Extension connection board · AlphaBNWAS Selector switch connection board · AlphaBNWAS motion sensor · Cable to connect Main Unit to Main Connection board, 2 meter
G-002350
G-002364 G-002368 G-002369 G-002370
G-002351 G-002352 G-002374 G-002354 G-002355 G-002357
G-002353 G-002356 G-002371 G-002359 G-002360 G-002361 G-006949 G-002371 G-002372 G-002373 G-002375 NL1-003200
www.pronav.no
Centers of Excellence
JRC Tokyo 1-7-32 Tatsumi, Koto-ku Tokyo 135-0053 Japan +81 3 5534 7800
JRC/Alphatron Marine B.V. Schaardijk 23 3063 NH Rotterdam The Netherlands +31 10 453 4000
JRC Shanghai Floor 9-A Building C2, Shanghai International Trade Center, 1599 New Jinqiao Road, Pudong, Shanghai, China 201206 +86-21-2024-0607
JRC/ProNav AS Hovlandsveien 52 4374 Egersund Norway +47 5146 4300
JRC South East Asia 100 Pasir Panjang 118518 Singapore Singapore +65 6863 0335
JRC Americas 1205 Butler Road TX 77573 Houston United States of America +1 281 271 4600
Product and/or specifications could change without notice
© All rights reserved, JRC/AM -20.06/207/2