The Gel Series Battery is designed for power supply under
extreme weather conditions. It can be designed with AGM or PVC
separator by using strong grids, high purity lead, and patented Gel
electrolyte. With a 15-year design life, it has rapid charging
acceptance and floating or cyclic endurance.

Application

The Gel Series Battery is ideal for use in applications where
power supply is required under extreme weather conditions.

General Features

  • Nominal Voltage: 12V
  • Battery Model: 6FM100G 12Volt 100Ah
  • Rated Capacity (10Hour rate): 100Ah
  • Cells Per Battery: 6
  • Approx Weight: 28.0Kg
  • Internal Resistance: Full charged at 25 (77 ): Approx 5m
  • Max. Discharge Current: 800A(5s)
  • Floating Design Life @ 25 (77 ): 15 years

Construction

The Gel Series Battery is constructed with strong grids, high
purity lead, and patented Gel electrolyte. It can be designed with
AGM or PVC separator.

Specification

Capacity @ 25 (77 )10Hour rate(10A/10.8V)5Hour rate(17A/10.8V)3Hour rate(25A/10.8V)1Hour rate(55A/10.5V)
100Ah85Ah75Ah55Ah

Capacity affected by Temp(10 HR)

40 (104 )25 (77 )0 (32 )-15 (5 )
102%100%85%65%

Self Discharge @ 25 (77 )

After 3 months storageAfter 6 months storageAfter 12 months storage
91%82%64%

Charge method @ 25 (77 )

Cycle UseFloat Use
14.5-14.9V (Initial charging current less than 30A)13.6-13.8V

National Sales Centre and Technical Support

  • National Sales Centre: 010 202 3400
  • Technical Support: 010 202 3500
  • Website: www.acdc.co.za

Product Usage Instructions

  • Avoid short circuit.
  • Do not charge in a sealed container.
  • Keep sparks and flames away.
  • For constant voltage charge, use the following:
    • Cycle use: 14.5-14.9V
    • Standby use: 13.6-13.8V
    • Initial current: 30.0A

Gel Series Battery

NSB100-12

Gel series is specially designed for power supply under extreme weather condition.It can be designed with AGM or PVC separator
byusing strong grids, high purity lead and patented Gel electrolyte,With 15-year design life,ait has rapid charging acceptance and floating or cyclic endurance.

Application

· Emergency Power System · Communication equipment · Telecommunication systems · Uninterruptible power supplies · Solar energy, wind energy storage system

· Power tools · Alarm system · Marine equipment · Medical equipment · Fire and Security System

General Features
· Heavy Duty Grid · Mechanized assembly · Non-spillable construction · High Reliability and Stability · Sealed and Maintenance-free · Long Life and low self-discharge design

Construction

· Positive……..Lead dioxide

· Negative……..Lead

· Electrolyte……..Sulfuric acid

· Safety Valve……..EPDR

· Separator……..PVC or AGM

· Terminal……..Copper

· Container……..ABS(UL94-HB) / Flame Retardant ABS (UL94-V0)

· Positive……..Lead dioxide

Specification

Nominal Voltage

12V

Battery Model

Rated capacity (10Hour rate)

100Ah

Cells Per battery

6

Dimension

Length 331mm±1.5

Width 173mm±1.5

Height 213mm±1.5

Total Height 218mm±2

Approx Weight

28.0Kg

Internal Resistance

Full charged at 25 (77 ): Approx 5m

Max.discharge current

800A(5s)

Floating design life @ 25 (77 )

15 years

Capacity @ 25 (77 )

10Hour rate(10A/10.8V) 100Ah

5Hour rate(17A/10.8V) 85Ah

3Hour rate(25A/10.8V) 75Ah

1Hour rate(55A/10.5V) 55Ah

Capacity affected by Temp(10 HR)

40 (104 ) 102%

25 (77 ) 100%

0 (32 ) 85%

-15 (5 ) 65%

Self Discharge @ 25 (77 )

After 3 months storage 91%

After 6 months storage 82%

After 12 months storage 64%

Charge method @ 25 (77 )

Cycle Use Float Use

14.5-14.9V (Initial charging current less than 30A) 13.6-13.8V

Outer Dimension(mm)

Terminal Type(mm)

18

10.5

9

24

3

6FM100G 12Volt 100Ah

Caution: -Avoid short circuit -Do not charge in sealed container -Keep sparks,flame away

Constant voltage charge

-Cycle use:14.5-14.9V

-Standby use:13.6-13.8V

Pb

-Initial current:30.0A

331

213 218

173

7

24.5 M6

Constant Current(Amp) and Constant Power(Watt) Discharge Table at 25°C (77°F)

F.V / TIME
A 9.60V
W
A 10.20V
W
A 10.50V
W
A 10.80V
W
A 11.10V
W

5min 360.00 3816.00 330.00 3597.00 306.04 3366.46 278.67 3065.33 241.00 2723.30

10min 220.00 2336.40 220.83 2451.25 211.00 2373.75 201.67 2299.00 190.00 2194.50

15min 175.00 1872.50 160.83 1793.29 150.00 1695.00 140.00 1603.00 130.00 1508.00

30min 115.00 1242.00 109.17 1228.13 105.83 1206.50 101.00 1166.55 94.00 1099.80

1h 60.00 654.00 62.00 697.50 60.00 684.00 58.00 669.90 55.00 643.50

2h 35.00 381.50 33.58 379.49 32.92 376.90 32.08 370.56 31.25 365.63

3h 26.00 286.00 25.50 288.15 25.00 286.25 24.50 284.20 23.50 276.13

4h 21.00 231.00 20.00 227.00 19.00 218.50 18.67 217.47 18.33 216.33

5h 17.54 192.96 17.21 195.31 17.00 195.50 16.25 189.31 15.54 183.39

8h 11.58 128.57 11.40 129.39 11.25 129.38 10.96 127.66 10.67 125.87

10h 11.00 122.10 10.50 119.18 10.30 118.45 10.00 116.50 9.75 115.05

20h 5.70 64.13 5.60 63.56 5.53 63.60 5.46 63.61 5.40 63.72

National Sales Centre – 010 202 3400 | Technical – 010 202 3500

www.acdc.co.za

TH IN K ELECTRICAL

Gel Series Battery

NSB100-12

Discharge characterstic Curve

Voltage (V)

2.16/6.48/13.0
1.85/5.55/11.1 1.80/5.40/10.8 1.75/5.25/10.5 1.70/5.10/10.2 1.65/4.95/9.90 1.60/4.80/9.60

0.25C 0.20C 0.17C 0.12C 0.1C

0.55C 0.40C

0.05C

3C

2C 1C

7min 15min 27min 1h 2h 3h 4h
Discharge time

5h 8h 10h 20h

Relationship between charging voltage and temperature

Capacity(%)

Cycle service life in relation to depth of discharge

120

100

80

60

100%DOD

80%DOD

40

30%DOD

20

0

200

400

600

800 1000 1200 1400

Number of cycles (cycles)

Constant voltage charging characteristic (0.25CA, at 25°C)

Charged Volume Current Voltage

(V/12V) (V/8V) (V/6V) (V/4V) (V/CE)

15.6 10.4 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 13.8 9.2 6.9 4.6 2.3 13.2 8.8 6.6 4.4 2.2
-10

Cycle Use Standby Use

0

10

20

30

40

50 60

Ambient temperature(¥)

Temperature effects on float life

2.30V/Cell 5
1

Life (years)

0

10

20

30

40

50

Temperatura(¥)

(%) (XCA) (V) 140

120 0.25 15.0
100 0.20 14.0 80 60 0.15 13.0 40 0.10 12.0

Charged Volume Charge Voltage

20 0.05 11.0

Charging Current

0

0

0 2 4 6 8 10 12 14 16 18 20

Charging time (hours)

Capacity (%)

Self-discharge characteristic

11 0

100

90

80

70

60

50

40

0

2

4

6

8

10 12 14 16 18 20

Storage time: months

Charge Volume (%) Charge Currient (CA)

Capacity (%)

Life characteristics of standby use

120 100
80 60 40 20
0

Testing conditions: floating voltage: 2.27 to 2.30V /cell Ambient temperature: 25 ¥ ()

1

2

3

Life (years)

Charge Voltage (V)

Charge characterstic for standby use

15 7.5 5.0 14 7.0 4.7 13 6.5 4.3 12 6.0 4.0 11 5.5 3.7

Charge Volume
Charge Voltage
Discharge 100% (0.05 CA*20h) 50% (0.05 CA*10h)
Charge Charge Voltaje 2.275V /cell Charge Current 0.1 CA
Temperature 25

120 100 80 60 40

10 5.0 3.3

20
Charge Current

9 4.5 3.0

0

0 2 4 6 8 10 12 14 16 18 20 24 28
Charge Time (h)

0.24 0.20 0.16 0.12 0.08 0.04
0

National Sales Centre – 010 202 3400 | Technical – 010 202 3500