APCCHVA Operator Adapter
Product Information
Product Name: Operator Adapter APCCHVA
Manufacturer: Cutler-Hammer
Compatible with: C361 and C371 Variable Depth Operating
Mechanisms and C371 Flex ShaftTM Flexible Cable Operating
Mechanisms
Part Number: P/N 87416628, 87569298
Product Usage Instructions
- Position the mounting plate (item1) on the inside of the
enclosure, behind the opening provided. - Discard the Cutler-Hammer spring bracket that is normally
installed inside the enclosure flange, behind the C-H handle
mechanism. - Assemble the Cutler-Hammer handle mechanism through the opening
in the enclosure and through the mounting plate. Omit the cap screw
and lockwasher that fits into the bottom hole of the handle
mechanism. - Attach the bottom of the slide arm (item 2) to the offset arm
of the lock release mechanism. Use two flat washers (item 6), two
lockwashers (item 7), and two hex nuts (item 8). Do not tighten
until parts are adjusted. - The handle safety lock release mechanism is adjustable in two
places:- Check the adjustment of the factory installed roller bracket.
The door latch should hit against the latch stop portion of the
roller bracket when the door is closed and latched. Adjust up or
down if necessary. The attached mechanism will then provide the
necessary up-down motion required to operate the release mechanism
in the C-H handle mechanism. - Adjust the length of the slide arm assembly. With proper
adjustment of the slide arm, the safety lock (on Cutler-Hammer
handle mechanism) should release just before the master door is
fully latched. Lengthen slide arm if safety lock releases too soon.
Shorten slide arm if safety lock releases too late.
- Check the adjustment of the factory installed roller bracket.
Note: Before and after installation, make sure to check the
function, fits, and clearances of all equipment to ensure proper
and safe operation. If the completed installation does not function
properly or fails to meet any applicable codes, standards, or
regulations, do not attempt to make alterations or operate the
equipment. Report any issues to Hoffman Customer Service.
OPERATOR ADAPTER APCCHVA
Installation Instructions for Cutler-Hammer C361 and C371 Variable Depth Operating Mechanisms and C371 Flex ShaftTM Flexible Cable Operating Mechanisms (For parts list, see page 2)
For floor-mounted enclosures with disconnect on the right flange, see pages 3-7 (flexible cable mechanism, see pages 18-22)
Master Door
For one-, two-, and three-door free-standing enclosures with the disconnect on the right flange, see pages 8-12 (flexible cable mechanism, see pages 18-22)
Master Door
Master Door
For floor-mounted enclosures with the disconnect on the centerpost, see pages 13-17 (flexible cable mechanism, see pages 18-22)
Master Door
Rev. E
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
P/N 87416628
87569298
WARNING
The functions, fits, and clearances of the installation described hereon are calculated from information supplied by the manufactures of the equipment to be installed. Be certain to check the function, fits, and clearances of all equipment both before
and after installation to assure that is operates properly and safely and meets all applicable codes, standards, and regulations. In the event the completed installation does not function properly or fails to meet any such codes, standards, or regulations, do not attempt to make alterations or operate the equipment. Report such facts immediately to: Hoffman Customer Service 2100 Hoffman Way Anoka, MN 55303 763 422 2211 http://hoffman.nvent.com/contact-us
PARTS LIST Operator Adapter, Catalog Number APCCHVA for Cutler-Hammer C361, C371 Disconnects
Item No. . . . . . Part Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Part No. . . . . . . . . Quantity 1 . . . . . . . . . . . . Mounting Plate for C-H C361, C371 . . . . . . . . . . 87400022 . . . . . . . 1 2 . . . . . . . . . . . . Slide Arm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26250001 . . . . . . . 1 3 . . . . . . . . . . . . Shoulder Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26149001 . . . . . . . 1 4 . . . . . . . . . . . . Screw, 1/4-20×7/8 Hex HD . . . . . . . . . . . . . . . . . . 99401030 . . . . . . . 1 5 . . . . . . . . . . . . Lockwasher, 1/4 Spring . . . . . . . . . . . . . . . . . . . . . 99401318 . . . . . . . 1 6 . . . . . . . . . . . . Washer, Flat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22101003 . . . . . . . 2 7 . . . . . . . . . . . . Lockwasher, 1/4 Int. . . . . . . . . . . . . . . . . . . . . . . . . 99401300 . . . . . . . 2 8 . . . . . . . . . . . . Nut, 1/4-20 Hex . . . . . . . . . . . . . . . . . . . . . . . . . . . 99401406 . . . . . . . 2 9 . . . . . . . . . . . . Door Catch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23101002 . . . . . . . 1 10 . . . . . . . . . . . Screw, 10-32×3/8 Pan HD . . . . . . . . . . . . . . . . . . 99401007 . . . . . . . 2 11 . . . . . . . . . . . Lockwasher, #10 Int. . . . . . . . . . . . . . . . . . . . . . . . 99401307 . . . . . . . 2 12 . . . . . . . . . . . Label, (extra) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26147001 . . . . . . . 1 13 . . . . . . . . . . . Installation Instruction . . . . . . . . . . . . . . . . . . . . . . 87416628 . . . . . . . 1
– 2 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
INTRODUCTION
This installation instruction is for Cutler-Hammer C361, C371 (variable depth) mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two-door, floor-mounted, enclosures with the disconnect on the right flange.
Master Door
INSTALLATION STEPS
Step 1 – Position mounting plate (item1) on the inside of the enclosure, behind the opening provided.
Step 2 – Discard the Cutler-Hammer spring bracket which is normally installed inside the enclosure flange, behind the C-H handle mechanism.
Step 3 – Assemble the Cutler-Hammer handle mechanism through the opening in the enclosure and through the mounting plate. Omit cap screw and lockwasher which fits into bottom hole of the handle mechanism.
Step 4 – Install the slide arm (item 2) through the slot in the bottom of mounting plate (item 1) and over the defeater part of the handle assembly (on C-H handle mechanism). Place the smaller diameter end of the shoulder collar (item 3) through the oval slot in the slide arm. Install long cap screw (item 4) with lockwasher (item 5) through shoulder collar into the bottom mounting hole of the C-H handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (C-H part) per Cutler-Hammer instructions.
Step 5 – Attach the bottom of the slide arm (item 2) to the offset arm of the lock release mechanism. Use two flat washers (item 6), two lockwashers (item 7), and two hex nuts (item 8). Do not tighten until parts are adjusted. (see Step 6 – (B) )
Step 6 – The handle safety lock release mechanism is adjustable in two places.
(A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up-down motion required to operate the release mechanism in the C-H handle mechanism.
(B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on Cutler- Hammer handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late.
Step 7 – Attach the door catch (item 9), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 10) and lockwashers (item 11). The door catch prevents the door from being opened when the handle mechanism is in the “ON” position. The door catch may be easily bent up or down to hook properly on the door hasp of the Cutler- Hammer handle mechanism.
Step 8 – Drill and tap holes in panel as shown in diagram and table 1. See Cutler-Hammer instructions for locating extra holes for fuse clips.
Step 9 – Mount switch or circuit breaker using Cutler-Hammer instructions and parts. C-H connecting rod must be cut off per Cutler-Hammer instructions. See table 2 for depth dimensions used to determine length of rod.
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 3 –
For Floor-Mounted, Two-Door, Enclosures With Disconnect on Right Flange
* Parts of lock release mechanism
– 4 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For Floor-Mounted, Two-Door, Enclosures With Disconnect on Right Flange
Hole Pattern For Disconnect Switch C361NC/C361SC C361ND/C361SD C361NE/C361SE C361NF/C361SF
Size 30 AMP 60 AMP 100 AMP 200 AMP
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 5 –
For Floor-Mounted, Two-Door, Enclosures With Disconnect on Right Flange
Hole Pattern For Circuit Breaker HMCP, FS, FH, EHD FDB, FD, HFD HMCP, JS, JH, JL, JD, JDB, HJD, JDC HMCP, HK, KS, KD, DK, KDB, HKD
LH, LS, LC
Frame Size 150 AMP 250 AMP 400 AMP 600 AMP
– 6 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For Floor-Mounted, Two-Door, Enclosure With Disconnect on Right Flange
Circuit Breaker or Disconnect Switch
C361NC (30A) C361SC (30A) C361ND (60A) C361SD (60A) C361NE (100A) C361SE (100A)
C361NF (200A)
Frame Size
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
C361SF (200A)
HMCP, FS, FH, EHD, FDB, FD, HFD JS, JH, JL HMCP
KH, KS, DK, KDB, KD, HKD, KDC HMCP
LH, LS, LC
– – – –
150A 250A 250A 400A 400A 600A
H 60.12″ HIGH 4.250
4.250
4.250
4.250
4.063
4.063
DO NOT INSTALL DO NOT INSTALL
H 72.12″ HIGH 10.250 10.250 10.250 10.250 10.063 10.063
8.469
8.469
6.484 12.484
6.438 6.438
12.438 12.438
6.000 12.000
6.000 DO NOT INSTALL
12.000 10.094
TABLE 1
J
K
2.593 2.593 2.593 2.593 2.468 2.468
.938
4.000 4.000 4.000 4.000 5.500 5.500
8.500
L
M
7.125 9.750 7.125 9.750 7.125 11.875
15.500
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
N
P
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
Size of Mounting Holes
10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF
5/16-18 UNC
.938
8.500 15.500 – – – – – – – – – – – – 5/16-18 UNC
2.734 3.250 3.250 3.078 3.078 4.000
4.500 7.250 7.250 8.438 8.438 9.53
1.375 1.375 1.375 1.719 1.719 2.750
– – – – .422 .422 .422 .422 .344
—- —-
6.948 6.948
2.750 2.750
6.948 3.180
6.948 4.000
10.050 4.320
8-32 UNC 10-32 UNF 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC
Hoffman Disconnect Enclosure Description Two-Door, Floor-Mounted Disconnect on Right Flange
TABLE 2 Enclosure Depth C 12.13
18.13
24.13
Cutler-Hammer D (1) 10.91
16.91 (2) 22.91 (2)
1) This dimension is used to determine length to cut Cutler-Hammer connecting rods. See Cutler-Hammer instructions
2) This dimension may be greater than the depth range of standard Cutler-Hammer connecting rods. A six inch platform is provided with 24.13 inch deep enclosures to reduce the depth for disconnect mounting. The platform can be eliminated if longer connecting rods are ordered from Cutler-Hammer. (C371-CS1 or C371-CS2)
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 7 –
INTRODUCTION
This installation instruction is for Cutler-Hammer C361, C371 (variable depth) mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman one-, two-, and three-door, free-standing, enclosures with the disconnect on the right flange.
Master Door
INSTALLATION STEPS
Step 1 – Position Mounting plate (item 1) on the inside of the enclosure, behind the opening provided.
Step 2 – Discard the Cutler-Hammer spring bracket which is normally installed inside the enclosure flange behind the C-H handle mechanism.
Step 3 – Assemble the Cutler-Hammer handle mechanism through the opening in the enclosure and through the mounting plate. Omit cap screw and lockwasher which fits into bottom hole of the handle mechanism.
Step 4 – Install the slide arm (item 2) through the slot in the bottom of the mounting plate (item 1) and over the defeater part of the handle assembly (on C-H handle mechanism). Place the smaller diameter end of the shoulder collar (item 3) through the oval slot in the slide arm. Install long cap screw (item 4) with lockwasher (item 5) through shoulder collar into the bottom mounting hole of the C-H handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (C-H part) per Cutler-Hammer instructions.
Step 5 – Attach the bottom of the slide arm (item 2) to the offset arm of the lock release mechanism. Use two flat washers (item 6), two lockwashers (item 7), and two hex nuts (item 8). Do not tighten until parts are adjusted. (see Step 6 – (B) ) )
Step 6 – The handle safety lock release mechanism is adjustable in two places.
(A) Check the adjustment of the factory installed roller bracket. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up-down motion required to operate the release mechanism in the C-H handle mechanism.
(B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on Cutler- Hammer handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late.
Step 7 – Attach the door catch (item 9), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 10) and lockwashers (item 11). The door catch prevents the door from being opened when the handle mechanism is in the “ON” position. The door catch may be easily bent up or down to hook properly on the door hasp of the Cutler- Hammer handle mechanism.
Step 8 – Drill and tap holes in panel as shown in diagram and table. See Cutler-Hammer instructions for locating extra holes for fuse clips.
Step 9 – Mount switch or circuit breaker using Cutler-Hammer instructions and parts. Cutler-Hammer connecting rod assembly must be cut off per Cutler-Hammer instructions. See table 2 for depth dimensions used to determine length of rod.
– 8 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For One-, Two-, and Three-Door, Free-Standing Enclosures With Disconnect on Right Flange
87569298
* Parts of lock release mechanism
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 9 –
For One-, Two-, and Three-Door, Free-Standing Enclosures With Disconnect on Right Flange
Hole Pattern For Disconnect Switch C361NC/C361SC C361ND/C361SD C361NE/C361SE C361NF/C361SF
Size 30 AMP 60 AMP 100 AMP 200 AMP
– 10 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For One-, Two-, and Three-Door, Free-Standing Enclosures With Disconnect on Right Flange
Hole Pattern For Circuit Breaker HMCP, FS, FH, EHD FDB, FD, HFD HMCP, JS, JH, JL, JD, JDB, HJD, JDC HMCP, HK, KS, KD, DK, KDB, HKD
LH, LS, LC MH, MS, MC NH, NS, NC
Size 150 AMP 250 AMP 400 AMP 600 AMP 800 AMP 1200 AMP
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 11 –
For One-, Two-, and Three-Door, Free-Standing Enclosure with Disconnect on Right Flange
Circuit Breaker or Disconnect Switch
C361NC (30A) C361SC (30A) C361ND (60A) C361SD (60A) C361NE (100A) C361SE (100A)
C361NF (200A)
C361SF (200A)
HMCP, FS, FH, EHD, FDB, FD, HFD
JS, JH, JL HMCP
KH, KS, DK, KDB, KD, HKD, KDC HMCP LH, LS, LC
MH, MS, MC
NH, HS, HC
Frame Size – – – – – – – – – – – – – – – – – – – – – – – – – – – –
– – – –
150A 250A 250A 400A 400A 600A 800A
1200A
H 62.81″ HIGH
4.70 4.70 4.70 4.70 4.51 4.51
2.92
2.92
6.93
6.89 6.89
6.45
6.45 4.56
N/A
N/A
H 72.12″ HIGH 6.250 6.250 6.250 6.250 6.063 6.063
4.469
4.469
8.484
8.438 8.438
8.000
8.000 6.109 DO NOT INSTALL DO NOT INSTALL
TABLE 1
H
H
74.81″ 84.12″
HIGH HIGH
10.70 12.250
10.70 12.250
10.70 12.250
10.70 12.250
10.51 12.063
10.51 12.063
8.92 10.469
8.92 10.469
12.93 14.484 12.89 14.438 12.89 14.438 12.45 14.000 12.45 14.000 10.56 12.109 N/A 8.547
N/A 8.457
H 90.12″ HIGH 15.250 15.250 15.250 15.250 15.063 15.063
13.469
13.469
17.484
17.438 17.438
17.000
17.000 15.109
11.547
11.547
J
2.593 2.593 2.593 2.593 2.468 2.468 .938
.938
2.750 3.250 3.250 3.078 3.078 4.000 4.000
4.000
K
4.000 4.000 4.000 4.000 5.500 5.500 8.500
8.500
4.500 7.250 7.250 8.438 8.438 9.530 14.750
14.750
L
7.125 9.750 7.125 9.750 7.125 11.875 15.500
15.500
1.375 1.375 1.375 1.719 1.719 2.750 2.750
2.750
M
– – – – – – – – – – – – – – – – – – – – – – – – – – – –
– – – –
– – – – .438 .438 .438 .438 .359 .359
.359
N
– – – – – – – – – – – – – – – – – – – – – – – – – – – –
– – – –
– – – – 6.948 6.948 6.948 6.948 10.050 10.050
10.050
P
– – – – – – – – – – – – – – – – – – – – – – – – – – – –
– – – –
– – – – 2.750 2.750 3.180 4.000 4.320 7.880
7.880
Size of Mounting
Holes 10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF
5/16-18 UNC
5/16-18 UNC
8-32 UNC
10-32 UNF 1/4-20 UNC
1/4-20 UNC
1/4-20 UNC 1/4-20 UNC
1/4-20 UNC
1/4-20 UNC
Hoffman Disconnect Enclosure Description One- and Two-Door, Free-Standing Disconnect on Right Flange Three-Door, Free-Standing Disconnect on Right Flange Two-Door, Free-Standing Disconnect on Right Flange
TABLE 2 Enclosure Depth C 18.13 20.13 24.13 18.13 24.13 12.12 18.12
24.12
Cutler-Hammer D (1) 10.91
16.91 (2) 22.91 (2)
15.91
21.91 (2) 9.90
16.90 (2) 21.90 (2)
1) This dimension is used to determine length to cut Cutler-Hammer connecting rods. See Cutler-Hammer instructions
2) This dimension may be greater than the depth range of standard Cutler-Hammer connecting rods. A six inch platform is provided with 24.13 inch deep enclosures to reduce the depth for disconnect mounting. The platform can be eliminated if longer connecting rods are ordered from Cutler-Hammer. (C371-CS1 or C371-CS2)
– 12 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
INTRODUCTION
This installation instruction is for Cutler-Hammer C361, C371 (variable depth) mechanisms. These mechanisms are for disconnect switches and circuit breakers mounted in Hoffman two-door, floor-mounted, enclosures with the disconnect on the centerpost.
Master Door
INSTALLATION STEPS
Step 1 – Position Mounting plate (item 1) on the inside of the enclosure, behind the opening provided in the centerpost.
Step 2 – Discard the Cutler-Hammer spring bracket which is normally installed inside the enclosure flange behind the C-H handle mechanism.
Step 3 – Assemble the Cutler-Hammer handle mechanism through the opening in the enclosure and through the mounting plate. Omit cap screw and lockwasher which fits into bottom hole of operating handle.
Step 4 – Cut 2 1/2″ off bottom end of slide arm (item 2). (bottom end has rectangular holes only)
Step 5 – Install the slide arm (item 2) through the slot in the bottom of mounting plate (item 1) and over the defeater part of the handle assembly (on C-H handle mechanism). as shown. Place the smaller diameter end of the shoulder collar (item 3) through the oval slot in the slide arm. Install long cap screw (item 4) with lockwasher (item 5) through shoulder collar into the bottom mounting hole of the C-H handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door hasp (C-H part) per Cutler-Hammer instructions.
Step 6 – Attach the bottom of the slide arm (item 2) to the offset arm of the lock release mechanism. Use two flat washers (item 6), two lockwashers (item 7), and two hex nuts (item 8). Do not tighten until parts are adjusted.
Step 7 – Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on Cutler-Hammer handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late.
Step 8 – Attach the door catch (item 9), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 10) and lockwashers (item 11). The door catch prevents the door from being opened when the handle mechanism is in the “ON” position. The door catch may be easily bent up or down to hook properly on the door hasp of the Cutler- Hammer handle mechanism.
Step 9 – Drill and tap holes in panel as shown in diagram and table 1. See Cutler-Hammer instructions for locating extra holes for fuse clips.
Step 10 – Mount switch or circuit breaker using Cutler-Hammer instructions and parts. Cutler-Hammer connecting rod assembly must be cut off per Cutler-Hammer instructions. See table 2 for depth dimensions used to determine length of rod.
* NOTE: Optional channel support kit, Cutler-Hammer C371-CS6, is recommended when installing 600 AMP circuit breakers in 72 1/8″ high enclosures.
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 13 –
For Floor-Mounted, Two-Door Enclosures With Disconnect on Centerpost
– 14 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For Floor-Mounted, Two-Door Enclosures With Disconnect on Centerpost
Hole Pattern For Disconnect Switch C361NC/C361SC C361ND/C361SD C361NE/C361SE C361NF/C361SF
Size 30 AMP 60 AMP 100 AMP 200 AMP
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 15 –
For Floor-Mounted, Two-Door Enclosures With Disconnect on Centerpost
Hole Pattern For Circuit Breaker HMCP, FS, FH, EHD FDB, FD, HFD HMCP, JS, JH, JL, JD, JDB, HJD, JDC HMCP, HK, KS, KD, DK, KDB, HKD
LH, LS, LC
Frame Size 150 AMP 250 AMP 400 AMP 600 AMP
– 16 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For Floor-Mounted, Two-Door Enclosure With Disconnect on Centerpost
Circuit Breaker or Disconnect Switch
C361NC (30A) C361SC (30A) C361ND (60A) C361SD (60A) C361NE (100A) C361SE (100A)
C361NF (200A)
Frame Size
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
C361SF (200A)
HMCP, FS, FH, EHD, FDB, FD, HFD JS, JH, JL HMCP
KH, KS, DK, KDB, KD, HKD, KDC HMCP
LH, LS, LC
– – – –
150A 250A 250A 400A 400A 600A
H 60.12″ HIGH 4.250
4.250
4.250
4.250
4.063
4.063
DO NOT INSTALL DO NOT INSTALL
H 72.12″ HIGH 10.250 10.250 10.250 10.250 10.063 10.063
8.469
8.469
6.484 12.484
6.438 6.438
12.438 12.438
6.000 12.000
6.000 DO NOT INSTALL
12.000 10.094
TABLE 1
J
K
3.781 3.781 3.781 3.781 3.656 3.656
2.125
4.000 4.000 4.000 4.000 5.500 5.500
8.500
L
M
7.125 9.750 7.125 9.750 7.125 11.875
15.500
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
N
P
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
– – – – – – – – – – – – – – – – – – – – – – – –
– – – –
Size of Mounting Holes
10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF 10-32 UNF
5/16-18 UNC
2.125
8.500 15.500 – – – – – – – – – – – –
5/16-18 UNC
3.922 4.438 4.438 4.266 4.266 5.188
4.500 7.250 7.250 8.438 8.438 9.53
1.375 1.375 1.375 1.719 1.719 2.750
– – – – 1.610 1.610 1.610 1.610 1.532
—- —-
6.948 6.948
2.750 2.750
6.948 3.180
6.948 4.000
10.050 4.320
8-32 UNC 10-32 UNF 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC
Hoffman Disconnect Enclosure Description Two-Door, Floor-Mounted Disconnect on Centerpost
TABLE 2 Enclosure Depth C 12.13
18.13
24.13
Cutler-Hammer D (1) 10.91
16.91 (2) 22.91 (2)
1) This dimension is used to determine length to cut Cutler-Hammer connecting rods. See Cutler-Hammer instructions
2) This dimension may be greater than the depth range of standard Cutler-Hammer connecting rods. A six inch platform is provided wi th 24.13 inchdeep enclosures to reduce the depth for disconnect mounting. The platform can be eliminated if longer connecting rods are ordered from Cutler-Hammer. (C371-CS1 or C371-CS2)
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 17 –
INTRODUCTION
This installation instruction is for Cutler-Hammer C371 Flex ShaftTM (flexible cable) mechanisms. These mechanisms are for circuit breakers mounted in Hoffman disconnect enclosures.
Two-door enclosure with disconnect on right flange
Master Door
Two-door enclosure with disconnect on centerpost
Master Door
One-, two-, and three-door enclosure with disconnect on right flange
Master Door
INSTALLATION STEPS
Step 1 – Discard Hoffman mounting plate (item 1) which is not required for this installation.
Step 2 – Assemble the Cutler-Hammer Flex ShaftTM handle mechanism and cable toggle mechanism to the enclosure flange opening. Omit cap screw and lockwasher which fits into bottom hole of Cutler-Hammer handle mechanism.
Step 3 – Modify slide arm (item 2) only if it is being installed in an enclosur e with disconnect on centerpost. (cut 2.5 inches off the bottom end of slide arm. Bottom end has rectangular holes only)
Step 4 – Install the slide arm (item 2) over the defeater part of the handle assembly (on C-H handle mechanism). Place the smaller diameter end of the shoulder collar (item 3) through the oval slot in the slide arm. Install long cap screw (item 4) with lockwasher (item 5) through shoulder collar into the bottom mounting hole of the C-H handle mechanism and tighten. The slide arm and defeater should move up and down smoothly. Install door interlock lever (C-H part) per Cutler-Hammer instructions.
Step 5 – Attach the bottom of the slide arm (item 2) to the offset arm of the lock release mechanism. Use two flat washers (item 6), two lockwashers (item 7), and two hex nuts (item 8). Do not tighten until parts are adjusted. (see Step 6 – (B) )
Step 6 – The handle safety lock release mechanism is adjustable.
(A) Check the adjustment of the factory installed roller bracket on enclosures with disconnect on right flange. The door latch should hit against the latch stop portion of the roller bracket when the door is closed and latched. Adjust up or down if necessary. The attached mechanism will then provide the necessary up-down motion required to operate the release mechanism.
(B) Adjust the length of the slide arm assembly. With proper adjustment of the slide arm, the safety lock (on Cutler- Hammer handle mechanism) should release just before the master door is fully latched. Lengthen slide arm if safety lock releases too soon. Shorten slide arm if safety lock releases too late.
Step 7 – Attach the door catch (item 9), provided by Hoffman, to the tapped spacer on the door using the bottom set of mounting holes. Use two screws (item 10) and lockwashers (item 11). The door catch prevents the door from being opened when the handle mechanism is in the “ON” position. The door catch may be easily bent up or down to hook properly on the door interlock lever of the Cutler-Hammer handle mechanism.
Step 8 – Assemble the C-H linkage between outer handle assembly and the toggle mechanism (inside). See C-H Flex ShaftTM instructions.
Step 9 – Drill and tap holes in panel as shown in diagram and table. See Cutler-Hammer instructions for locating holes.
Step 10 – Mount circuit breaker and actuator mechanism using Cutler-Hammer Flex ShaftTM instructions and parts.
– 18 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For Floor-Mounted, Two-Door Enclosures With Disconnect on Right Flange For Floor-Mounted, Two-Door Enclosures With Disconnect on Centerpost For One-, Two-, and Three-Door, Free-Standing Enclosures With Disconnect on Right Flange
87569298
* Parts of lock release mechanism
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 19 –
For Floor-Mounted, Two-Door Enclosures With Disconnect on Right Flange For One-, Two-, and Three-Door, Free-Standing Enclosures With Disconnect on Right Flange
– 20 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
For Floor-Mounted, Two-Door Enclosures With Disconnect on Centerpost
87569298
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
– 21 –
For Floor-Mounted, Two-Door Enclosures With Disconnect on Right Flange For Floor-Mounted, Two-Door Enclosures With Disconnect on Centerpost For One-, Two-, and Three-Door, Free-Standing Enclosures With Disconnect on Right Flange
Circuit Breaker Frame Size F J K
Hole Size
8-32 1/4-20 1/4-20
TABLE 1 Subpanel Drilling
X 1.375 1.375 1.719
Y 4.500 7.250 8.438
Cmin 1.38 1.38 1.88
TABLE 2 Location of Disconnect Operating Handle
Hoffman Disconnect Enclosure Description
Enclosure Height
Two-Door, Floor-Mounted Disconnect on Right Flange
60.13 72.13
Two-Door, Floor-Mounted Disconnect on Centerpost
60.13 72.13
One-, Two-, and Three-Door, Modular Free-Standing Disconnect on Right Flange
72.13 84.13 90.13
Two-Door, Free-Standing Disconnect on Right Flange
62.81 74.81
H 5.81 11.81 5.81
11.81 7.81
13.81 16.81 6.26 12.26
– 22 –
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
87569298
Rev. E
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
P/N 87416628
87569298
Rev. E
© 2018 Hoffman Enclosures Inc.
PH 763 422 2211 · nVent.com/HOFFMAN
P/N 87416628
87569298