La Marche P25-dspurewave-1 Purewave Inverter Instructions

P25-DSPUREWAVE-1 PureWave Inverter

Product Information

The PureWave Inverter is a high-quality inverter designed to
provide a pure sine wave output of 120 VAC. With a capacity of
2kVA, it is capable of handling various types of loads and
batteries. This inverter is built with CSA and UL compliance,
ensuring safety and reliability. It is particularly suitable for
the Marine market due to its robust construction and
performance.

The PureWave Inverter features an LCD display that allows users
to easily monitor and configure the system. The display provides
valuable information about the inverter’s status and settings. LED
indicators are also present to provide visual feedback on the
system’s operation.

With its surge capability, the PureWave Inverter can handle
complex loads, making it versatile for different applications.
Despite its powerful performance, it is housed in a compact and
lightweight enclosure, making it easy to install and transport.

The inverter supports a 120 VAC output and can be powered by
either a 12 VDC or 24 VDC input. It has a built-in charger and
provides pure sine wave output with over 90% efficiency. The
inverter is designed for wall mounting and complies with UL 458
standards for electrical safety.

Product Usage Instructions

1. Power Source: Connect the PureWave Inverter to a suitable
power source. Ensure that the input voltage matches the
requirements of the inverter (12 VDC or 24 VDC).

2. Load Connection: Connect your desired load to the 120 VAC
output of the inverter. Make sure the load is compatible with the
inverter’s power rating.

3. Monitoring and Configuration: Use the LCD display on the
inverter to monitor the system’s status and configure settings if
necessary. Refer to the user manual for detailed instructions on
navigating the display menu.

4. LED Indicators: Keep an eye on the LED indicators to get
visual feedback on the inverter’s operation. A solid green light
indicates normal operation, while a solid red light indicates a
fault. A flashing red light indicates a warning or alert
condition.

5. Surge Capability: The PureWave Inverter is capable of
handling complex loads with its surge capability. It can start
devices that require higher initial power, such as motors or
compressors.

6. Charging: If you need to charge batteries, the inverter has a
built-in charger. Connect the batteries to the appropriate
terminals and follow the instructions in the user manual for
configuring the charging settings.

7. Transfer Times: The inverter supports seamless transfers
between shore power and inverter power. When there is a power
source change, the inverter will automatically switch between shore
power and inverter power without interruption.

8. Mounting: Install the PureWave Inverter on a suitable wall
mount, ensuring it is securely fixed. Follow the installation
instructions provided in the user manual to ensure proper
mounting.

Please consult the user manual for more detailed information on
specific features, troubleshooting, and advanced
configurations.

PureWave Inverter
Pure Sine Wave 120 VAC (2kVA)
The La Marche PureWave, Pure Sine Wave inverter built with CSA and UL compliance, which makes this Inverter / Charger ideal for the Marine market. The LCD display allows to monitor and configure the system, making it a flexible Inverter / Charger for various types of loads and batteries. Its surge capability allows it to start complex loads, everything in a light and compact enclosure.

Standard Features

120 VAC Output

12 or 24 VDC Input

LCD Display

LED Indicators

Solid Green Solid Green Solid Red Flashing Red

· Output is powered by shore power · Output is powered by battery · Fault occurs in the inverter · Warning condition occurs in the unit

Built in Charge Pure Sine Wave >90% Efficiency Wall Mount UL 458

Transfer Times
Shore to Inverter Inverter to Shore

<15 ms <10 ms

AC Output

AC Input

Comm. ACC Input

Remote Port

ON/OFF Switch

Alert LED

Pos. DC Terminal

Neg. DC Terminal

Ventialtion Fan Reset Button AC Cover Ventialtion Fan

AC ON/OFF

LCD Display

Alarm Indicator

Battery Level

Operation Mode

Battery Charging Indicator

Load Level Indicator
Load Connected/Disconnected

Specifications subject to change without notice
P25-DSPUREWAVE-1 ECN 23296 11/22

La Marche Mfg. (A U.S. Company) 106 Bradrock Drive, Des Plaines, IL 60018
Tel: 847.299.1188 Fax: 847.299.3061 [email protected] www.lamarchemfg.com

Specifications
Nominal DC Input Voltage Normal Range DC Input Voltage Range
DC Under Voltage Shutdown Level DC Under Voltage Shutdown Recovery Level
DC Over Voltage Shutdown Level
Output Voltage Waveform Nominal AC Output Voltage Total Harmonic Distortion Voltage (% THD)
Output Frequency Continous Output Power
Surge Output Rating Load Power Fact
Optimum Efficiency No Load Power Consumption @ Nominal Voltage SPS Off Power Consumption @ Nominal Power
AC Input Voltage AC Input Voltage Range Normal Operating AC Input Voltage Range
AC Input Frequency
Dimensions (L x W x H)
Operating Ambient Temperature Range Maximum Operating Temperature Storage Temperature Range Relative Humidity Cooling EMC and Safety Electromagnetic Compability

MI-2K-12V-A6

MI-2K-24V-A6

12 VDC

DC Input

24 VDC

11 – 17 VDC

22 – 30 VDC

10.5 VDC (Default)

21 VDC (Default)

13.1 VDC (Default)

26.2 VDC (Default)

18 VDC

AC Output
Pure Sine Wave

32 VDC

120 VAC L-N
< 5% THD of Fundamental (Voltage) < 10% THD Full Input Voltage Range (Full Load) < 20% for 230V Model when DC Input is in Range 16-18VDC

Rated Power (-20°C to 40°C) 2000 W / 000

60 Hz ±1 Hz
Ambient Temperature at Full Load 40°C

Derated Power at Maximum Ambient (60°C) 1700 W

0.6 to 1.0 (lead or lag) >91% <25 W <0.5 W
AC Input
120 VAC ± 2 V 85 – 140 VAC 100 – 130 VAC
60 ± 5 Hz (Default), 50 ± 5 Hz
Mechanical Specification
370 x 275 x 100
Environmental
-20 to 40°C
+ 0°C -40 to 95°C
5% ~ 95% non-condensing Force Cooling
ITS listed and c(ETL)us marked complies with CSA C22.2 No. 107.1, UL458 with marine supplement (optional drip shield required) ABYC E-11, A-31, A-32
Complies with FCC Part 15, Subpart B, Class B and with CAN ICES-3 (B) Emissions

www.lamarchemfg.com

References