1405 Series EMC Networking Virtual Edge Platform
Product Information
The Dell EMC Networking Virtual Edge Platform 1405 Series is a
system that provides virtual edge networking capabilities. It comes
in different models, including VEP1425, VEP1445, and VEP1485, with
varying core processors and storage capacities. The system supports
optical transceivers and is compliant with Class 1 laser radiation
limits. Some models do not include wireless or Bluetooth
capabilities.
Product Usage Instructions
Chapter 3: VEP1405 Series Installation
- Unpack the Dell EMC Networking Virtual Edge Platform 1405
Series. - Follow the step-by-step procedures for rack or desk
mounting. - Insert the modules into the system.
- Connect the system to a power source.
CAUTION: To avoid electrostatic discharge (ESD)
damage, wear grounding wrist straps when handling the
equipment.
WARNING: Only trained and qualified personnel
should install the equipment. Read the provided guide before
installation. Disconnect the power cable before servicing.
Chapter 5: Support
For more information about the Dell EMC Networking Virtual Edge
Platform 1405 Series, refer to the following documents:
- Dell EMC Networking Virtual Edge Platform (VEP) 1405 Series
Operating System Installation Guide - Dell EMC Networking Virtual Edge Platform (VEP) 1405 Series
Diag OS and Tools Release Notes - Dell EMC Networking Virtual Edge Platform (VEP) 1405 Series
Technology Guide
Dell EMC Networking Virtual Edge Platform 1405 Series
Getting Started Guide
February 2023 Rev. A06
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2016 – 2023 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
Contents
Chapter 1: About this Guide……………………………………………………………………………………………..4 Related documents…………………………………………………………………………………………………………………………………………. 4 Information symbols…………………………………………………………………………………………………………………………………………5
Chapter 2: Site Preparations…………………………………………………………………………………………… 6 Site selection…………………………………………………………………………………………………………………………………………………… 6 Chassis mounting……………………………………………………………………………………………………………………………………………..6 Fans and airflow…………………………………………………………………………………………………………………………………………….. 10 Power………………………………………………………………………………………………………………………………………………………………10 Storing components………………………………………………………………………………………………………………………………………. 10
Chapter 3: VEP1405 Series Installation……………………………………………………………………………..11 Unpack……………………………………………………………………………………………………………………………………………………………..11 Platform power-up…………………………………………………………………………………………………………………………………………. 11
Chapter 4: Specifications……………………………………………………………………………………………….12 Chassis physical design…………………………………………………………………………………………………………………………………..12 Safety standards and compliance agency certifications……………………………………………………………………………… 17 Product recycling and disposal……………………………………………………………………………………………………………………… 17 Agency compliance………………………………………………………………………………………………………………………………………… 18 USA Federal Communications Commission statement…………………………………………………………………………… 18 Industry Canada Statement………………………………………………………………………………………………………………………19 Radiocommunication equipment compliance for Thailand……………………………………………………………………… 19 Brasil Aviso da Anatel…………………………………………………………………………………………………………………………… 20 European Union EMC directive conformance statement………………………………………………………………………..21 Japan VCCI compliance for Class A equipment……………………………………………………………………………………….21 Korean certification of compliance…………………………………………………………………………………………………………. 22 Mexico certification of compliance…………………………………………………………………………………………………………. 23 Taiwanese certification of compliance……………………………………………………………………………………………………. 23 Singapore certification of compliance…………………………………………………………………………………………………….. 23
Chapter 5: Support……………………………………………………………………………………………………… 24
Contents
3
1
About this Guide
This guide provides site preparation recommendations, step-by-step procedures for rack and desk mounting, inserting modules, and connecting to a power source for the Dell EMC Networking Virtual Edge Platform (VEP) 1405 series of systems.
CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment. WARNING: Only trained and qualified personnel can install this equipment. Read this guide before you install and power up this equipment. This equipment contains one power cable. Disconnect the power cable before servicing.
WARNING: This equipment supports optical transceivers, which comply with the limits of Class 1 laser radiation.
Figure 1. Class 1 laser product tag
WARNING: When the SFP transceiver is plugged in and a cable is not connected, visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports. Avoid exposure to laser radiation, and do not stare into open apertures.
Table 1. Regulatory compliance information for the VEP1405 series of systems
Marketing model number
Regulatory model Regulatory type
number
number
Remarks
VEP1425/VEP1425N E42W
E42W001
4-core, 120G SSD
VEP1445/VEP1445N E42W
E42W001
8-core, 240G/960G SSD
VEP1485/VEP1485N E42W
E42W001
16-core, 240G/2TB SSD
NOTE: The VEP1425N, VEP1445N, and VEP1485N system models do not include wireless or Bluetooth capabilities.
Related documents
For information about the Virtual Edge Platform 1405 (VEP1405) series of systems, see the following documents: Dell EMC Networking Virtual Edge Platform (VEP) 1405 Series Operating System Installation Guide Dell EMC Networking Virtual Edge Platform (VEP) 1405 Series Diag OS and Tools Release Notes Dell EMC Networking Virtual Edge Platform (VEP) 1405 Series Technology Guide
NOTE: For the most recent documentation, see the support site: https://www.dell.com/support.
4
About this Guide
Information symbols
This book uses the following information symbols: NOTE: The Note icon signals important operational information.
CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. NOTE: The Warning icon signals information about hardware handling that could result in injury.
NOTE: The ESD Warning icon requires that you take electrostatic precautions when handling the device.
About this Guide
5
2
Site Preparations
The Virtual Edge Platform 1405 series of systems, or VEP1405, are a universal customer premise equipment (uCPE) devices. The VEP1405 series connects the service provider edge or small to medium branch locations to the cloud, to host virtual network functions. For more information about VEP1405 series specifications, see the Chassis physical design section.
Site selection
Ensure that the area where you install your platform meets the following safety requirements: Near an adequate power source Connected to a properly grounded power outlet
WARNING: The VEP1405 series of systems AC power cord must be connected to a socket outlet that has properly wired earth ground. Environmental–platform location–continuous temperature range is 040°C (32104°F) Operating humidity: 5% to 85% (RH), noncondensing continuously 5% to 90% (RH), noncondensing Short term (< 1% of operational hour per year) In a dry, clean, well-ventilated, and temperature-controlled room, away from heat sources such as hot air vents or direct sunlight Away from sources of severe electromagnetic noise In a location that enables the VEP1405 series of systems to be out of direct view within the workplace For more information about platform storage and environmental temperatures, see Specifications.
Chassis mounting
The VEP1405 series supports the following mounting options: Desktop placement (rubber feet) Wall mount placement Rack-mounted using the optional rack mount tray
Desktop placement
The VEP1405 series includes four rubber feet that provide secure and stable placement of the unit on a flat surface.
Figure 2. VEP1405 series desktop placement
6
Site Preparations
Wall mount installation
The VEP1405 series includes the hardware that is required for wall mount installation. Using a torque screwdriver, affix the wall mount brackets to the VEP1405 series using the four M3 screws included.
NOTE: When driving the screws into the bracket and VEP1405 series unit, verify that 5 lb-in is the achieved torque setting. NOTE: If mounting the VEP1405 series to the wall using the wall mount bracket provided, removal of the rubber feet from the bottom of the VEP1405 series unit is not necessary. The VEP1405 series of systems include a wall mount bracket with cross-shaped cutout for the mounting screws. The wall mount bracket includes cross-shaped cutouts for the mounting screws. Wall mount bracket with cross-shaped cutout for the mounting screws
Figure 3. VEP1405 series wall mount installation – cross-shaped cutout To mount the VEP1405 series unit to the wall using the wall mount bracket provided, you must first anchor the screws into the wall surface. Depending on the type of wall surface, use the M3 screw and anchor to ensure a secure installation. The recommended M3 screw dimensions are as follows:
Site Preparations
7
Figure 4. VEP1405 series wall mount, installation anchor, and screw dimensions
NOTE: Before mounting the VEP1405 series to the wall, verify that the wall surface is strong enough to support a firm installation of the unit and can withstand the weight of the unit, power cable, and network cabling. Using the measurements provided in the following diagram, use the measurement in the red box to mark the distance between the two installation points:
Figure 5. VEP1405 series M3 screw installation points
After the brackets have been attached to the VEP1405 series unit and the screws that are mounted into the wall, place the brackets over the screws and slide the unit to one side to secure the unit in place.
8
Site Preparations
Figure 6. VEP1405 series wall mount bracket installation – cross-shaped cutout
Rack-mounted installation
As an option, the VEP1405 series can be mounted to a dual rack mount tray. Purchased separately, you can install the VEP1405 series to the dual rack mount tray using a torque screwdriver and the eight M3 screws included.
NOTE: When driving the screws into the bracket and VEP1405 series unit, verify that 5 lb-in is the achieved torque setting. NOTE: If mounting the VEP1405 series to a dual rack mount tray, removal of the rubber feet from the bottom of the VEP1405 series unit is not necessary.
Figure 7. VEP1405 series rack mount installation
Figure 8. VEP1405 series rack installation – front and back view
Site Preparations
9
Fans and airflow
Fan installation is done as part of the factory install and is based on the stock keeping unit (SKU) type. The VEP1405 series of systems support a DC fan unit with fan airflow starting from the bottom of the unit: Four core unit with single fan Eight core unit with two fans Sixteen core unit with two fans Position the unit in a well ventilated environment with clearance around the exhaust vents. The fan speed varies based on internal temperature monitoring. The platform never intentionally turns off the fans.
CAUTION: The fans are not field-replaceable.
CAUTION: For thermal considerations, do not stack the VEP1405 series platforms on top of each other. Do not place the external power supply on top of the VEP1405 series unit. Stacking the units or placing the power supply on top of a unit impairs cooling.
Power
Connect the platform to the applicable power source using the appropriate power cable. The VEP1405 series of systems ship with one external AC/DC power supply and one AC power cable. When installing AC platforms, follow the requirements of the National Electrical Code ANSI/NFPA 70, where applicable. The platform is powered-up when the power cable is connected between the platform and the power source.
CAUTION: Before servicing, ensure that the power cable is disconnected.
CAUTION: Use the power supply cable as the main disconnect device. Ensure that the socket-outlet is located near the equipment and is accessible.
Storing components
If you do not install the VEP1405 series unit and components immediately, properly store the platform and all optional components following these guidelines: The storage temperature range is from -40°C to 70°C (-40°F to 158°F) with humidity at 5% to 90% noncondensing Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts Store in a dust-free environment
NOTE: ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and its accessories. After you remove the original packaging, place the VEP1405 series unit and its components on an antistatic surface.
10
Site Preparations
3
VEP1405 Series Installation
To install the VEP1405 series unit, complete the installation procedures in the order that is presented in this section. Always handle the platform and its components with care.
NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and its components. As with all electrical devices of this type, take all the necessary safety precautions to prevent injury when installing this platform.
Unpack
NOTE: Before unpacking the platform, inspect the container and immediately report any evidence of damage.
When unpacking the VEP1405 series unit, ensure that the following items are included: One VEP1405 series system Micro-USB console cable One AC/DC power supply and AC power cable Wall mount hardware Dell EMC Networking Virtual Edge Platform (VEP) 1405 Getting Started Guide Safety and Regulatory Information Warranty and Support Information 1. Place the container on a clean, flat surface. 2. Open the container. 3. Carefully remove the unit from the container and place it on a secure and clean surface. 4. Remove all packing material. 5. Inspect the product and accessories for damage.
NOTE: If damage to the product or accessories is found, contact your Dell EMC sales representative for assistance.
Platform power-up
Before you turn on the system, reinspect the rack mounting or desktop placement of platform, and verify that the power supply to the VEP1405 series unit is secure. Verify the following: The ambient temperature around the unit, which may be higher than the room temperature, be within the limits that are
specified for the VEP1405 series of systems, see Specifications There is sufficient clearance around the unit All protective covers are in place
NOTE: If the components are mishandled, ESD damage can occur. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and its components.
Power up sequence
The fans immediately come on at high speed when the platform powers up. The fan speed slows as the platform continues to boot.
VEP1405 Series Installation
11
4
Specifications
This section lists the specifications for the VEP1405 series of systems. CAUTION: Operate the product at an ambient temperature between 0-40°C (32104°F). WARNING: There is a danger of explosion if the lithium battery is incorrectly replaced. Replace only with the same or equivalent type of battery. Dispose of the battery according to the manufacturer’s instructions. NOTE: For RoHS information, see https://www.dell.com/learn/tw/zh/twcorp1/envt-info-materials.
Chassis physical design
Table 2. Dell EMC Virtual Edge Platform (VEP) 1405 model descriptions
Model
CPU
Description
VEP1425
4-core
8 GB DDR4 16 GB eMMC 120 GB SSD 2x 2 Wi-Fi 6x 1 GB Copper RJ45 2x 10 GB SFP+ Versa software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 Low-energy Bluetooth (BLE) One fan
VEP1425N 4-core
8 GB DDR4 16 GB eMMC 120 GB SSD 6x 1 GB Copper RJ45 2x 10 GB SFP+ Versa software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 One fan
VEP1445
8-core
VEP1445
8-core
16 GB DDR4 16 GB eMMC 240 GB SSD 2x 2 Wi-Fi 6x 1 GB Copper RJ45 2x 10 GB SFP+ Versa software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 Low-energy Bluetooth (BLE) Two fans
32 GB DDR4
12
Specifications
Table 2. Dell EMC Virtual Edge Platform (VEP) 1405 model descriptions (continued)
Model
CPU
VEP1445N 8-core
VEP1485
16-core
VEP1485
16-core
VEP1485N 16-core
Description
16 GB eMMC 960 GB SSD 2x 2 Wi-Fi 6x 1 GB Copper RJ45 2x 10 GB SFP+ ADVA software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 Low-energy Bluetooth (BLE) Two fans
16 GB DDR4 16 GB eMMC 240 GB SSD 6x 1 GB Copper RJ45 2x 10 GB SFP+ Versa software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 Two fans
32 GB DDR4 16 GB eMMC 240 G SSD 2x 2 Wi-Fi 6x 1 GB Copper RJ45 2x 10 GB SFP+ Versa software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 Low-energy Bluetooth (BLE) Two fans
64 GB DDR4 16 GB eMMC 2 TB SSD 2x 2 Wi-Fi 6x 1 GB Copper RJ45 2x 10 GB SFP+ ADVA software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 Low-energy Bluetooth (BLE) Two fans
32 GB DDR4 16 GB eMMC 240 G SSD 6x 1 GB Copper RJ45 2x 10 GB SFP+ Versa software installed Trusted Platform Module (TPM) 2.0 – World-wide except China 2x USB 3.0 Two fans
Specifications
13
NOTE: For a listing of the supported optics guidelines for the VEP1405 series, see the Virtual Edge Platform 1405 Series Technology Guide.
Figure 9. VEP1405 series front view
1. Security lock port 2. USB port
NOTE: An additional USB port is located on the opposite side of the system.
3. System status indicator LED
Table 3. Front view system status indicator LED
Color
Status
Red
Power on
White
System is booting
Green
Operating system boots with diagOS
Blue
Reset button is pressed for more than five seconds
NOTE: See the Reset button behavior table below for more information.
Figure 10. VEP1405 series rear view (with port cover)
1. Port cover 2. Reset button
NOTE: After upgrading to UFW 2.2, the system response when you push the Reset button on a running VEP14xx switch is determined by the operating system that the switch is currently running.
NOTE: See the Reset button behavior table below for more information. 3. LED status indicators for SFP+ ports 4. SFP+ ports 5. Ethernet ports and LED status indicators 6. Power connection port
14
Specifications
NOTE: To prevent the VEP1405 series system console port from being accessed in a nonsecure location, the system ships from the factory with a plate covering the micro USB port. To uncover the port, use a #0 (2.5 mm) Phillips head screwdriver to loosen or remove the screw that holds the plate in place.
Figure 11. VEP1405 series back view (without port cover)
1. Micro USB serial console port 2. Reset button
NOTE: After upgrading to UFW 2.2, the system response when you push the Reset button on a running VEP14xx switch is determined by the operating system that the switch is currently running.
NOTE: See the Reset button behavior table below for more information.
3. LED status indicators for SFP+ ports 4. SFP+ ports 5. Ethernet ports and LED status indicators 6. Power connection port
Table 4. Back view system status indicator LED behavior
Class
Behavior
1000 Base-T LED
Link LED – Green or amber Solid green – Port is linked and running at maximum 1000M speed on ethernet port Solid amber – Port is linked and running at lower 100M or 10M speed on ethernet port Off – No link
Activity LED – Green NOTE: The LED flashes green during port activity.
SFP+ LED
Off – no port activity
Link LED – Green or amber Solid green – Port is linked and running at 10G speed Solid amber – Port is linked and running at 1G speed Off – No link
Activity LED – Green NOTE: The LED flashes green during port activity.
Off – no port activity
Specifications
15
Table 5. Reset button behavior
Action
Press the Reset button. When the system is powered off:
Behavior System powers on
Press the Reset button for more than 5 seconds: System reboots
NOTE: When the system is already powered on, Status indicator LED color changes to blue
the system responds as described in the Behavior Flag indicating a long push is set by the BIOS in the CMOS RAM
column.
Flag allows user to have the operating system detect a long button
push
NOTE: After upgrading to UFW 2.2, the system response when
you push the Reset button on a running VEP14xx switch is
determined by the operating system that the switch is currently
running.
Table 6. Chassis physical design
Parameter
Configuration option 1
Height
5.2 cm (2.0 in)
Width
20.8 cm (8.1 in)
Depth
20.0 cm (7.9 in)
Chassis weight with factoryinstalled components
4-core: 1.44 kg (3.17 lb) 8-core: 1.42 kg (3.13 lb) 16-core: 1.44 kg (3.17 lb)
Configuration option 2 5.2 cm (2.0 in) 20.8 cm (8.1 in) 20.0 cm (7.9 in) 8-core: 1.42 kg (3.13 lb) 16-core: 1.44 kg (3.17 lb)
NOTE: Chassis weight does not include the weight of the power supply.
Table 7. Environmental parameters
Parameter
Configuration option 1
Configuration option 2
Operating temperature
040°C (32°F104°F) continuously
040°C (32°F104°F) continuously
Operating humidity
5% to 85% (RH), noncondensing continuously
5% to 85% (RH), noncondensing continuously
5% to 90% (RH), noncondensing short- 5% to 90% (RH), noncondensing shortterm (< 1% of operational hour per year) term (< 1% of operational hour per year)
Storage temperature
40°-70°C (40° to 158°F)
40°-70°C (40° to 158°F)
Storage humidity
5% to 90% (RH), noncondensing
5% to 90% (RH), noncondensing
Maximum operational altitude
3,048 meters (10,000 ft) with no performance degradation to 950 meters (3117 ft)
3,048 meters (10,000 ft) with no performance degradation to 950 meters (3117 ft)
Maximum nonoperational altitude
10,668 meters (35,000 ft)
10,668 meters (35,000 ft)
Table 8. AC power requirements
Parameter
Configuration option 1
Power supply
100240 VAC 50/60 Hz
Maximum current draw per system – AC
100 VAC: 2.0A 240 VAC: 1.0A
Power consumption
Typical:
40 W (16 core) 35 W (8 core)
Configuration option 2
100240 VAC 50/60 Hz
100 VAC: 2.0A 240 VAC: 1.0A
Typical: 40 W (16 core) 35 W (8 core)
16
Specifications
Table 8. AC power requirements (continued)
Parameter
Configuration option 1 20 W (4 core) Maximum:
50 W (16 core) 45 W (8 core) 30 W (4 core)
Configuration option 2
Maximum: 50 W (16 core) 45 W (8 core)
NOTE: For the most current AC power requirements and power consumption specifications, see the Installation Guide at https://www.dell.com/support.
Safety standards and compliance agency certifications
CUS UL 60950-1, 2nd Edition Meets or exceeds Hi Pot and Ground Continuity testing per UL 60950-1.
CSA 60950-1-03, 2nd Edition EN 60950-1, 2nd Edition EN 60825-1, 1st Edition EN 60825-1 Safety of Laser Products–Part 1: Equipment Classification Requirements and User’s Guide EN 60825-2 Safety of Laser Products–Part 2: Safety of Optical Fibre Communication Systems FDA Regulation 21CFR 1040.10 and 1040.11 IEC 60950-1, 2nd Ed, including all National Deviations and Group Differences IEC 62368-1
Product recycling and disposal
You must recycle or discard this switch according to applicable local and national regulations. Dell EMC encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell EMC offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products.
Waste electrical and electronic equipment (WEEE) directive for recovery, recycle and reuse of IT and telecommunications products
Dell EMC switches are labeled in accordance with European Directive 2002/96/EC concerning waste electrical and electronic equipment (WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
Figure 12. The European WEEE symbol
In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, recycling and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE.
Specifications
17
Dell EMC products, which fall within the scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by WEEE. For information on Dell EMC product recycling offerings, see the WEEE Recycling instructions on Support. For more information, contact the Dell EMC Technical Assistance Center.
Agency compliance
The VEP1405 is designed to comply with the following safety and agency requirements:
India
This product conforms to the relevant Essential Requirements of TEC, Department of Telecommunications, Ministry of Communications, Govt of India, New Delhi-110001.
USA Federal Communications Commission statement
CAUTION: The use of external signal amplifiers in-line with the transceiver antennas is strictly prohibited.
NOTE: Some of the following declarations may apply only to systems that contain wireless capabilities
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures. Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
NOTE: The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only.
18
Specifications
Industry Canada Statement
This device complies with Industry Canada license-exempt RSS standards. Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1. l’appareil ne doit pas produire de brouillage, et 2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement. This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. This device complies with RSS-GEN, RSS-210, RSS-130, RSS-132, RSS-133, RSS-139, RSS-195, RSS-199 & RSS-247 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. Cet appareil est conforme à la norme RSS-GEN, RSS-210, RSS-130, RSS-132, RSS-133, RSS-139, RSS-195, RSS-199 & RSS-247 d’Industrie Canada. L’opération est soumise à la condition que cet appareil ne provoque aucune interférence nuisible. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested built-in radios. Cet appareil et son antenne ne doivent pas être situés ou fonctionner en conjonction avec autre antenne ou un autre émetteur, exception faites des radios intégrées qui ont été testées. The County Code Selection feature is disabled for products marketed in the US/Canada. La fonction de sélection de l’indicatif du pays est désactivée pour les produits commercialisés aux États-Unis et au Canada. Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
Caution:
1. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
2. Users should also be advised that high-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices.
Avertissement:
1. Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux;
2. De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL.
Radiocommunication equipment compliance for Thailand
The following is for radiocommunication equipment per act B.E. 2498:
Specifications
19
Figure 13. Radiocommunication compliance certificate
Figure 14. Radiocommunication compliance certificate translation
Brasil Aviso da Anatel
Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.
20
Specifications
Figure 15. Brasil Aviso da Anatel certificate
European Union EMC directive conformance statement
This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Dell EMC cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of this product, including the fitting of non-Dell EMC option cards. This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 32/CISPR34 and EN55032 / EN55034. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment.
NOTE: This is a Class A product. In a domestic environment, this device may cause radio interference, in which case, you may be required to take adequate measures. European Community Contact Dell EMC, EMEA – Central Dahlienweg 19 66265 Heusweiler Germany Tel: +49 172 6802630 Email: EMEA Central Sales
Japan VCCI compliance for Class A equipment
(VCCI) A
Specifications
21
This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
WARNING: Use the AC power cables with Dell EMC equipment only. Do not use Dell EMC AC power cables with any unauthorized hardware.
Wi-Fi and Bluetooth compliance certificate
5GHz
BTE compliance certificate
WWAN 20 5
Korean certification of compliance
Korean certification of compliance
A ()
(A) , .
Korean package label
[equipment type](Product Name) (Model) (Applicant) (Manufacturer) (Manufacturing Date) (Country of Origin)
Ethernet switch [model number] Dell Technologies [Manufacturer] [date] China
Radio compliance certificate
Korea (Korean warning statement is only required for devices contain 2400~2483 and/or 5725~5825 MHz radios). The following is the Korean radio compliance certification:
22
Specifications
Mexico certification of compliance
La operación de este equipo está sujeta a las siguientes dos condiciones: 1. Es posible que este equipo o dispositivo no cause interferencia perjudicial y 2. Este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.
Taiwanese certification of compliance
The Taiwanese radio certification of compliance is as follows: : 5.25-5.35
Singapore certification of compliance
Singapore radio compliance. Complies with IMDA Standards Registration number: N2515-19
Specifications
23
5
Support
The support site provides documents and tools to help you effectively use your equipment and mitigate network outages. Through the support site you can obtain technical information, access software upgrades and patches, download available management software, and manage your open cases. The support site provides integrated, secure access to these services. To access the support site, go to https://www.dell.com/support/. To display information in your language, scroll down to the bottom of the web page and select your country from the drop-down menu. To obtain product-specific information, enter the 7-character service tag or 11-digit express service code of your platform
and click the Submit button on the screen. To view the chassis service tag or express service code, locate the sticker underneath the system. To receive more technical support, click Contact Us. On the Contact Information web page, click Technical Support. To access platform documentation, go to https://www.dell.com/manuals/. To search for drivers and downloads, go to https://www.dell.com/drivers/.
24
Support
References
Materials – Restricted Material Compliance | Dell 台灣
Support | Dell US
Support for Dell EMC Networking VEP1425/VEP1445/VEP1485 | Documentation | Dell US
Support for Dell EMC Networking VEP1425/VEP1445/VEP1485 | Documentation | Dell US
Support for Dell EMC Networking VEP1425/VEP1445/VEP1485 | Drivers & Downloads | Dell US
Support for Dell EMC Networking VEP1425/VEP1445/VEP1485 | Overview | Dell US