SCHUKO Socket Outlet
Product Information: SCHUKO Socket Outlet 16 A 250 V~ with LED
Orientation Light and Shutter
The SCHUKO socket outlet 16 A 250 V~ with LED orientation light
and shutter is a device designed for electrical installations. It
provides a convenient and safe way to connect electrical devices to
the power supply. The socket outlet features a built-in LED
orientation light and a shutter for added safety.
Device Components:
- (1) Socket outlet base
- (2) Cover frame
- (3) Socket outlet insert
- (4) Light sensor
- (5) Light opening
Intended Use:
The socket outlet is intended for general use in electrical
installations. It should be installed by a qualified electrical
fitter to ensure proper installation and safe operation.
Product Characteristics:
The socket outlet features a light sensor that automatically
switches on the LED orientation light when it detects low light
conditions (twilight) and switches it off when the brightness is
sufficient. Please note that due to component tolerances, the
orientation lights may switch at different brightness values.
Mounting and Electrical Connection:
DANGER! Before carrying out any work on the
device, always disconnect it and switch off all corresponding
circuit breakers to avoid electric shock. Follow these steps for
proper installation:
- Install the socket outlet in a way that the light sensor (4) is
not covered. - Connect the socket outlet base (1) according to the provided
circuit diagram (see figure 2). - Mount the socket outlet base (1) in an appliance box, ensuring
that the connection contacts are at the bottom. - Fit the cover frame (2) and socket outlet insert (3) and fasten
them with screws.
Technical Data:
- Rated voltage: AC 250 V~
- Mains frequency: 50 / 60 Hz
- Standby power: 4
- Ambient temperature: N/A
- Power consumption: N/A
- Power factor: N/A
- Rated load current: 16 A (IL) max.
- Circuit breaker: N/A
- Number of LEDs: N/A
- Light color: N/A
- Clampable conductor cross-section: N/A
Warranty:
The warranty for the SCHUKO socket outlet is provided in
accordance with statutory requirements. Faulty devices should be
submitted or sent postage paid, along with a fault description, to
the responsible salesperson or service center.
Operating instructions
SCHUKO socket outlet 16 A 250 V~ with LED orientation light and shutter Order no. 4170 .. Socket outlet with earth pin 16 A 250 V~, LED orientation light and shutter Order no. 4489 ..
32563112 / 10870701 / 26.05.2023
Socket outlet 16 A 250 V~ with LED orientation light and shutter
Table of contents
1 Safety instructions ……………………………………………………………………………………………… 3 2 Device components ……………………………………………………………………………………………. 4 3 Intended use ……………………………………………………………………………………………………… 4 4 Product characteristics ……………………………………………………………………………………….. 4 5 Mounting and electrical connection ………………………………………………………………………. 5 6 Technical data …………………………………………………………………………………………………… 5 7 Warranty …………………………………………………………………………………………………………… 6
32563112
10870701
26.05.2023
2 / 6
Socket outlet 16 A 250 V~ with LED orientation light and shutter
1 Safety instructions
Serious injuries, fire or property damage are possible. Please read and follow the manual fully.
Installation only by persons with appropriate electrotechnical knowledge and experience in the following areas: The “5 safety rules” to be observed are: disconnect; secure against reconnection; determine that no voltage is present; ground and short-circuit; cover or block off adjacent live parts Selection of suitable tools, measuring devices and, if necessary, personal protective equipment Evaluation of the measurement results Selection of the electrical installation material to ensure the shutdown conditions IP protection ratings Installation of the electrical installation material Type of mains supply (TN system, IT system, TT system) and the resulting connection requirements (classic earthing, protective earthing, necessary additional measures, etc.)
Improper installation endangers your own life and the lives of people using the electrical system and there is a risk of serious damage to property, e.g. through fire. You are at risk of personal liability for personal injury and damage to property. Contact an electrical fitter!
Danger of electric shock. Always disconnect before carrying out work on the device or load. In so doing, take all the circuit breakers into account, which support dangerous voltages to the device and or load.
The device is not suitable for use in safety-related applications or as an emergency light.
This manual is an integral part of the product, and must remain with the customer.
32563112
10870701
26.05.2023
3 / 6
Socket outlet 16 A 250 V~ with LED orientation light and shutter
2 Device components
Image 1: Device components
(1)
Socket outlet base
(2)
Cover frame
(3)
Socket outlet insert
(4)
Light sensor
(5)
Light opening
3 Intended use
Socket outlet with LED orientation light and shutter
Stationary installation indoors in appliance box with dimensions according to DIN 49073
4 Product characteristics
Light sensor switches LED orientation light on at twilight, and switches it off again when the brightness is sufficient.
Due to component tolerances, the orientation lights may switch at different brightness values.
32563112
10870701
26.05.2023
4 / 6
Socket outlet 16 A 250 V~ with LED orientation light and shutter
5 Mounting and electrical connection
DANGER!
Electric shock when live parts are touched. Electric shocks can be fatal. Always disconnect device before carrying out work on it. For this, switch off all the corresponding circuit breakers, secure against being switched on again, and check that there is no voltage. Cover up adjacent live parts.
Image 2: Connection diagram
Install the socket outlet in such a way that the light sensor (4) (see figure 1) is not covered.
Connect socket outlet base (1) (see figure 1) in accordance with circuit diagram (see figure 2).
Mount socket outlet base (1) in an appliance box. Connection contacts of the socket outlet base must be at the bottom.
Fit the cover frame (2) and socket outlet insert (3) (see figure 1) and fasten with screws.
6 Technical data
Rated voltage Mains frequency Standby power Ambient temperature Power consumption Power factor Rated load current Circuit breaker Number of LEDs
AC 250 V~ 50 / 60 Hz
0.175 W 0 … +40°C approx. 0.35 VA approx. 0.70
16 A (IL) max. 16 A
4
32563112
10870701
26.05.2023
5 / 6
Socket outlet 16 A 250 V~ with LED orientation light and shutter
Light colour Clampable conductor cross-section
white 1.5 … 2.5 mm²
7 Warranty
The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with a fault description to your responsible salesperson (specialist trade / installation company / electrical specialist trade). They will forward the devices to the Gira Service Center.
Gira Giersiepen GmbH & Co. KG Elektro-InstallationsSysteme
Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald
Postfach 12 20 42461 Radevormwald
Deutschland
Tel +49(0)21 95 – 602-0 Fax +49(0)21 95 – 602-191
www.gira.de [email protected]
32563112
10870701
26.05.2023
6 / 6