R801T Endeavor Line Classic Series Gas Furnaces
Product Information:
- Product Name: Gas Furnaces R801T UH
- Model Number: R801T
- Efficiency: 80% A.F.U.E. (Annual Fuel Utilization
Efficiency) - Heating Stages: Single Stage
- Motor Type: Constant Torque
- Input Rates: 50-125 kBTU [14.6-36.6 kW]
- Configuration Options: Upflow/Horizontal
Product Usage Instructions:
- Ensure that the furnace is not approved or recommended for use
in mobile homes. - Standard Equipment:
- Limit controls
- Manual shut-off valve
- 100% safety lock out
- Cool fan off delay
- Field selectable heat fan off delay
- One hour automatic retry
- Power and self test diagnostics
- Flame sense current diagnostics
- Electronic air cleaner connections
- Twinning (built-in) features
- Humidifier connections
- Low speed continuous fan option
- Single speed option for heating and cooling applications
- Transformer
- Direct drive motor
- Multi-speed constant torque blower motor
- Solid bottom
- Input-BTU/Hr [kW]:
- R801T0503A14UH*NAS – 50,000 [15]
- R801T0754A17UH*NAS – 75,000 [22]
- R801T0754A21UH*NAS – 75,000 [22]
- R801T1005A21UH*NAS – 100,000 [29]
- R801T1255A24UH*NAS – 125,000 [37]
- Heat Ext. Static Pressure [kPa]:
- R801T0503A14UH*NAS – .18 [.05]
- R801T0754A17UH*NAS – .20 [.05]
- R801T0754A21UH*NAS – .20 [.05]
- R801T1005A21UH*NAS – .28 [.07]
- R801T1255A24UH*NAS – .28 [.07]
- Blower (D x W) [mm]:
- R801T0503A14UH*NAS – 11 x 6 [279 x 152]
- R801T0754A17UH*NAS – 11 x 7 [279 x 178]
- R801T0754A21UH*NAS – 11 x 7 [279 x 178]
- R801T1005A21UH*NAS – 11 x 10 [279 x 254]
- R801T1255A24UH*NAS – 11 x 10 [279 x 254]
- Motor H.P. [W] Type:
- R801T0503A14UH*NAS – 1/2 [373]
- R801T0754A17UH*NAS – 1/2 [373]
- R801T0754A21UH*NAS – 3/4 [560]
- R801T1005A21UH*NAS – 3/4 [560]
- R801T1255A24UH*NAS – 3/4 [560]
- Min. Circuit Ampacity:
- R801T0503A14UH*NAS – 8
- R801T0754A17UH*NAS – 8
- R801T0754A21UH*NAS – 9
- R801T1005A21UH*NAS – 10
- R801T1255A24UH*NAS – 11
- Min. Overload Protection Device: 15
- Max. Overload Protection Device: 15
- Heating Speed:
- R801T0503A14UH*NAS – Med
- R801T0754A17UH*NAS – Med
- R801T0754A21UH*NAS – Med-High
- R801T1005A21UH*NAS – Med
- R801T1255A24UH*NAS – Med-High
- Cooling Speed: High
- Cooling CFM @ Rating Point [L/s]:
- R801T0503A14UH*NAS – 1305 [616]
- R801T0754A17UH*NAS – 1402 [662]
- R801T0754A21UH*NAS – 1608 [759]
- R801T1005A21UH*NAS – 1840 [868]
- R801T1255A24UH*NAS – 1934 [913]
- Max. E.S.P. (In. W.C.) [kPa]:
- R801T0503A14UH*NAS – 0.9 [.22]
- R801T0754A17UH*NAS – 0.9 [.22]
- R801T0754A21UH*NAS – 0.9 [.22]
- R801T1005A21UH*NAS – 0.9 [.22]
- R801T1255A24UH*NAS – 0.9 [.22]
- Approx. Shipping Weight (Lbs.) [kg]:
- R801T0503A14UH*NAS – [weight]
- R801T0754A17UH*NAS – [weight]
- R801T0754A21UH*NAS – [weight]
- R801T1005A21UH*NAS – [weight]
- R801T1255A24UH*NAS – [weight]
Gas Furnaces R801T UH
EndeavorTM Line Classic® Series Gas Furnaces
R801T
80% A.F.U.E. Heating Stages: Single Stage Motor Type: Constant Torque Input Rates: 50-125 kBTU [14.6-36.6 kW] Configuration Options: Upflow/Horizontal
= A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures.
FORM NO. G11-662 REV. 1
Table of Contents R801T UH
Table of Contents
Features & Benefits …………………………………………………………3 Model Number Identification …………………………………………….4 Physical Data and Specifications ………………………………………5 Dimensional Data ……………………………………………………….. 6-7 Blower Performance Data ………………………………………………..8 Accessories ……………………………………………………………………9 Limited Warranty …………………………………………………………..12
2
Features and Benefits
· PlusOne® Diagnostics: Industry-first, 7-segment LED for quick & easy service
· PlusOne® Ignition System: Proven Direct Spark Ignition (DSI) for reliability and longevity
· Low Profile, 34-inch Cabinet: Makes our furnaces ideal for space-constrained installations
· Hemmed Cabinet & Door Edges and Quarter-Turn Door Fasteners (Upflow/Horizontal only): Allows for safe, toolless access and serviceability
· Removable Heat Exchanger: Built with a primary aluminized steel and secondary stainless steel construction, provides maximum corrosion resistance, thermal fatigue reliability and improved serviceability
Features and Benefits R801T UH
· Pre-Marked Hoses: Offers easier identification and installation
· Blower Shelf Design: Ensures serviceability in all furnace orientations
· Replaceable Collector Box: Enables replacement of only the collector box, and doesn’t require replacement of the heat exchanger
· Venting with 2 or 3-inch PVC: Offers options that can be used on all furnace heating input sizes
· Self-Priming Condensate Trap: Allows for on-going water saturation within the trap to keep it primed, and eliminates the need for seasonal service on the condensate trap
3
Model Number Identification R801T UH
Gas Furnaces
R
80
1
T
050
3
A
14
UH
S
N
A
S
Brand
Furnace Efficiency
Stages of Heating
Motor Type
Heating Input
AC Max. Capacity
Major Series
Width
Position
NOx
Controls
Minor
Option Code
Series
R – Rheem 80 – 80% AFUE 1 – Single-Stage T – Constant Torque
050 – 50K BTUH [14.7 kW] 075 – 75K BTUH [22.0 kW] 100 – 100K BTUH [29.3 kW] 125 – 125K BTUH [36.6 kW]
3 – 3 ton drive A – 1st Design 14 – 14″ Width
4 – 4 ton drive Series 17 – 17.5″ Width
5 – 5 ton drive
21 – 21″ Width
24 – 24.5″ Width
UH – Upflow Horizontal
S – Standard N – Non-Comm. A – 1st Series S – Standard Grade N – Low NOx
[ ] Designates Metric ConversionsAVAILABLE MODELS R801T0503A14UHSNAS R801T0754A17UHSNAS R801T0754A21UHSNAS R801T1005A21UHSNAS R801T1255A24UHSNAS R801T0503A14UHNNAS R801T0754A17UHNNAS R801T0754A21UHNNAS R801T1005A21UHNNAS R801T1255A24UHNNAS
STANDARD EQUIPMENT Limit controls Manual shut-off valve 100% safety lock out Cool fan off delay Field selectable heat fan off delay One hour automatic retry Power and self test diagnostics Flame sense current diagnostics Electronic air cleaner connections Twinning (built-in) features Humidifier connections Low speed continuous fan option Single speed option for heating and cooling applications Transformer Direct drive motor Multi-speed constant torque blower motor Solid bottom
WARNING
THIS FURNACE IS NOT APPROVED OR RECOMMENDED
FOR USE IN MOBILE HOMES
4
Physical Data and Specifications R801T UH
Physical Data and Specifications–Upflow Models
MODEL NUMBERS R801T Constant Tq-UH Series
R801T0503A14UH*NAS R801T0754A17UH*NAS R801T0754A21UH*NAS R801T1005A21UH*NAS R801T1255A24UH*NAS
Input-BTU/Hr [kW]
50,000 [15]
75,000 [22]
75,000 [22]
100,000 [29]
125,000 [37]
Heating Capacity BTU/Hr [kW] ®
40,000 [12]
60,000 [18]
60,000 [18]
80,000 [23]
100,000 [29]
Heat Ext. Static Pressure [kPa]
.18 [.05]
.20 [.05]
.20 [.05]
.28 [.07]
.28 [.07]
Blower (D x W) [mm]
11 x 6 [279 x 152]
11 x 7 [279 x 178]
11 x 7 [279 x 178]
11 x 10 [279 x 254]
11 x 10 [279 x 254]
Motor H.P. [W] Type
1/2 [373]
1/2 [373]
3/4 [560]
3/4 [560]
3/4 [560]
5 Spd Constant Torque 5 Spd Constant Torque 5 Spd Constant Torque 5 Spd Constant Torque 5 Spd Constant Torque
Min. Circuit Ampacity
8
8
9
10
11
Min. Overload Protection Device
15
15
15
15
15
Max. Overload Protection Device
15
15
15
15
15
Heating Speed
Med
Med
Med-High
Med
Med-High
Cooling Speed
High
High
High
High
High
Cooling CFM @ Rating Point [L/s]
1305 [616]
1402 [662]
1608 [759]
1840 [868]
1934 [913]
Max. E.S.P. (In. W.C.) [kPa]
0.9 [.22]
0.9 [.22]
0.9 [.22]
0.9 [.22]
0.9 [.22]
Temperature Rise Range °F [°C]
25-55 [13.9-30.6]
25-55 [13.9-30.6]
25-55 [13.9-30.6]
40-70 [22-39]
35-65 [19.4-36.1]
Max. Outlet Air Temp. °F [°C]
155 [68.3]
155 [68.3]
160 [71.1]
180 [82.2]
165 [73.8]
Approx. Shipping Weight (Lbs.) [kg] AFUE ©
110 [50] 80.00%
125 [57] 80.00%
140 [64] 80.00%
140 [64] 80.00%
150 [68] 80.00%
NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1/2″ [12 mm] N.P.T. © In accordance with D.O.E. test procedures. ® See Conversion Kit Index Form for high altitude derate. *S=Standard, N=Low NOx
This furnace does not meet air district requirements of 14 ng/J NOx emissions limit. This furnace is not eligible for the Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
This furnace is to be installed for propane firing only in air districts requiring 14 ng/J NOx emission limits. Operating in natural gas mode is in violation of these Rules.
[ ] Designates Metric Conversions5
Dimensional Data R801T UH
Upflow Application
Dimensional Data: Upflow Model
MODEL R801T-
A
B
C
D
E
MINIMUM CLEARANCE (IN.) [mm]
SHIP
F
LEFT SIDE
RIGHT SIDE
BACK TOP FRONT
WGTS. VENT (LBS.) [kg]
050
141/2 [356] 1227/32 [326] 105/8 [270] 111/2 [292] 17/8 [48] 0 4 [102] 0 1 [25] 3 [76] 6 [152] 110 [50]
075417 171/2 [445] 1611/32 [415] 123/8 [314] 151/2 [381] 21/2 [64] 0 3 [76] 0 1 [25] 3 [76] 6 [152] 125 [57]
075421/100 211/2 [533] 1927/32 [504] 141/8 [359] 181/2 [470] 21/2 [64] 0
0
0 1 [25] 3 [76] 6 [152] 140 [64]
125
241/2 [622] 2311/32 [593] 157/8 [403] 221/2 [559] 21/2 [64] 0
0
0 1 [25] 3 [76] 6 [152] 150 [68]
NOTES: May require a 3″ [76 mm] to 4″ [102 mm] or 3″ [76 mm] to 5″ [127 mm] adapter. May be 0″ [0 mm] with type B vent. May be 1″ [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.
6
Horizontal Application
Dimensional Data R801T UH
WARNING
THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION
ON ITS BACK, WITH ACCESS DOORS FACING UPWARDS.
Dimensional Data: Horizontal Model
MODEL R801T
A
B
C
D
E
MINIMUM CLEARANCE (IN.) [mm]
SHIP
F
SUPPLY AIR SIDE
RETURN AIR SIDE
BACK
TOP
FRONT
WGTS. VENT (LBS.) [kg]
050
141/2 [356] 1227/32 [326] 105/8 [270] 111/2 [292] 17/8 [48] 4 [102] 4 [102] 0 1 [25] 3 [76] 6 [152] 110 [50]
075417 171/2 [445] 1611/32 [415] 123/8 [314] 151/2 [381] 21/2 [64] 3 [76] 3 [76] 0 1 [25] 3 [76] 6 [152] 125 [57]
075421/100 211/2 [533] 1927/32 [504] 141/8 [359] 181/2 [470] 21/2 [64]
0
0
0 1 [25] 3 [76] 6 [152] 140 [64]
125
241/2 [622] 2311/32 [593] 157/8 [403] 221/2 [559] 21/2 [64]
0
0
0 1 [25] 3 [76] 6 [152] 150 [68]
NOTES: May require a 3″ [76 mm] to 4″ [102 mm] or 3″ [76 mm] to 5″ [127 mm] adapter. May be 0″ [0 mm] with type B vent. May be 1″ [25 mm] with type B vent.
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes.
7
Blower Performance Data R801T UH
Air Flow Performance – 80% Single Stage Upflow/ Horizontal Constant Torque
AIR FLOW PERFORMANCE – 80% SINGLE STAGE DOWNFLOW CONSTANT TORQUE
INPUT [BTU] CABINET
WIDTH [IN]
50K 14″
75K 17″
75K 21″
100K 21″
125K 24″
AIRFLOW CONTROL SETTINGS
Factory Setting Fan Cool
Heat or Heat/Cool Cool
Factory Setting Cooling Factory Setting Fan Cool Cool Heat or Heat/Cool
Factory Setting Cooling Factory Setting Fan Cool Heat or Heat/Cool Cool
Factory Setting Cooling Factory Setting Fan Cool Heat or Heat/Cool Cool
Factory Setting Cooling Factory Setting Fan Cool Cool Heat or Heat/Cool
Factory Setting Cooling
SPEED TAP/ WIRE
COLORS
Low/Red Medium Low/ Yellow
Medium/ Purple Medium High/ Blue
High/Black Low/Red Medium Low/ Yellow Medium/ Purple Medium High/ Blue High/Black Low/Red Medium Low/ Yellow Medium/ Purple Medium High/ Blue High/Black Low/Red Medium Low/ Yellow Medium/ Purple Medium High/ Blue High/Black Low/Red Medium Low/ Yellow Medium/ Purple Medium High/ Blue High/Black
CFM AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN
0.1 915 963 997 1123 1246 967 1206 1301 1413 1590 1216 1314 1400 1605 1686 1304 1406 1520 1709 1807 1295 1649 1796 1878 1943
0.2 777 894 976 1130 1244 916 1147 1260 1369 15568 1174 1271 1356 1576 1659 1233 1348 1465 1658 1758 1216 1598 1746 1828 1893
0.3 674 834 947 1121 1232 865 1087 1214 1324 1530 1132 1229 1315 1544 1628 1162 1289 1409 1607 1710 1138 1548 1698 1781 1846
0.4 598 781 911 1101 1211 814 1027 1164 1277 1486 1088 1188 1276 1509 1595 1091 1229 1353 1557 1663 1061 1499 1652 1735 1801
0.5 541 733 870 1071 1185 763 966 1111 1229 1437 1043 1147 1239 1473 1559 1018 1168 1296 1507 1616 986 1449 1606 1691 1757
0.6 498 689 825 1036 1154 712 905 1058 1181 1387 998 1105 1200 1436 1524 944 1106 1239 1457 1569 914 1400 1561 1647 1714
0.7 460 646 779 997 1121 661 843 1005 1130 1342 952 1063 1161 1400 1489 869 1044 1183 1407 1522 844 1351 1515 1604 1673
0.8 419 602 732 957 1087 610 783 955 1079 1303 905 1019 1120 1365 1455 793 982 1128 1358 1475 778 1302 1469 1560 1631
0.9 370 555 687 920 1054 558 722 910 1026 1276 858 974 1076 1333 1426 716 920 1073 1308 1428 715 1252 1422 1516 1589
1.0 304 504 646 888 1024 505 662 870 972 1265 811 926 1027 1303 1400 637 859 1019 1260 1380 657 1201 1374 1470 1547
8
BOTTOM RETURN FILTER RACK FOR UPFLOW APPLICATION: RXGF-CB
SIDE RETURN FILTER RACK: RXGF-CD
FILTER RACK FILTER SIZES* INCHES [mm]
MODEL
RXGF-CB (UPFLOW/ HORIZONTAL)
RXGF-CD (UPFLOW) SIDE RETURN
R801TA050
R801TA075417 R801TA075421/
R801TA100 R801TA125
121/4 x 25 [311 x 635] 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 223/4 x 25 [578 x 635]
153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635]
4″ FLUE ADAPTER: RXGW-C01
Indoor Coil Casings
MODEL NUMBER RXBC-D14AI RXBC-D17AI RXBC-D21AI RXBC-D21BI RXBC-D24AI
Accessories R801T UH
WARNING: IMPORTANT NOTICE
A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS.
FURNACE WIDTH IN. [mm]
SOLID BOTTOM KIT NO.
BASE PLATE NO.
BASE PLATE SIZE
IN. [mm]
141/2 [356] 171/2 [445] 211/2 [533] 241/2 [622]
RXGB-D14 RXGB-D17 RXGB-D21 RXGB-D24
AE-61874-01 AE-61874-02 AE-61874-03 AE-61874-04
115/8 x 239/16 [295 x 598] 151/8 x 239/16 [384 x 598] 185/8 x 239/16 [473 x 598] 255/8 x 239/16 [651 x 598]
For High Altitudes
OPTION CODE FOR HIGH ALTITUDE: U.S. None required for high altitudes.
HIGH ALTITUDE CONVERSION KITS: U.S. None required for high altitudes.
80+ HIGH ALTITUDE INSTRUCTIONS CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes.
High altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information.
9
Notes R801T UH
10
Notes R801T UH
11
GENERAL TERMS OF LIMITED WARRANTY*
Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts (Registration Required) …………………………Ten (10) Years Heat Exchanger ………………………………..Twenty (20) Years
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
© 2022 Rheem Manufacturing Company. Rheem trademarks owned by Rheem Manufacturing Company. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Heating, Cooling & Water Heating · 5600 Old Greenwood Road Fort Smith, Arkansas 72908 · www.rheem.com
PRINTED IN U.S.A. 10/22 QG FORM NO. G11-662 REV. 1