Minka Lavery 72133-66 Noble Hill Black Outdoor Hardwired Wall Lantern Sconce Instruction Manual

72133-66 Noble Hill Black Outdoor Hardwired Wall Lantern Sconce

Product Information

The product being installed is a Model #72133-66 fixture. The
installation instructions include preparing for installation,
connecting the wires, and finishing the installation.

The installation process involves shutting off power at the fuse
or circuit breaker, removing the old fixture with mounting
hardware, unpacking the new fixture and laying out all parts,
positioning the mounting plate on the wall, attaching the mounting
plate to the outlet box with outlet box screws, securing the
mounting plate with woodscrews, installing glass panels into the
holder of fixture body, and installing candelabra base bulbs up to
60 watts or CFL or LED equivalent in accordance with the fixture
specification.

The fixture has three wires: black (hot), white (neutral), and
green or bare copper (ground). The electrical wires are connected
with wire connectors, ensuring they are secured. If the outlet box
has a ground wire, connect the fixture’s ground wire to it.
Otherwise, connect the fixture’s ground wire directly to the
mounting plate using a green screw provided.

To prevent moisture from entering the outlet box and causing a
short, clear silicone sealant should be used to outline the outside
of the back plate where it meets the wall, leaving a space at the
bottom to allow moisture a means to escape.

It is important to note that the fixture should be installed by
a qualified electrician to ensure proper wiring and
installation.

Product Usage Instructions

  1. Shut off power at the fuse box or circuit breaker box and
    remove the old fixture including mounting hardware.
  2. Carefully unpack your new fixture and lay out all parts in a
    clear area. Take care not to misplace any small parts necessary for
    installation.
  3. Remove screws and rubber washers and separate mounting plate
    from backplate.
  4. Position mounting plate on the wall and mark the location of
    four drywall anchors. Pre-drill holes for drywall anchors and
    insert them into the wall.
  5. Attach mounting plate to outlet box with outlet box screws.
    Note that the side of the mounting plate marked GND must face
    out.
  6. Place woodscrews through holes into drywall anchor to secure
    mounting plate as shown in Fig.1.
  7. The support cable is provided to support the weight of the
    fixture while wiring. Align the fixture to the mounting plate and
    attach the hook on the end of the support cable into a slot located
    on the mounting plate. Carefully allow the support cable to support
    the weight of the fixture while wiring.
  8. Remove screws, separate cover from fixture body, and install
    glass panels into the holder of the fixture body and secure them
    with tabs on top and bottom.
  9. Install candelabra base bulbs up to 60 watts or CFL or LED
    equivalent (not included) in accordance with the fixture
    specification. DO NOT EXCEED THE MAXIMUM WATTAGE RATING.
  10. Connect the electrical wires as shown in Fig.2, ensuring that
    all wire connectors are secured. If the outlet box has a ground
    wire, connect fixture’s ground wire to it. Otherwise, connect
    fixture’s ground wire directly to mounting plate using green screw
    provided.
  11. Tuck wire connectors neatly into outlet box.
  12. Align backplate onto mounting plate and secure with rubber
    washers and screws.
  13. Place cover onto fixture body and secure with screws.
  14. To prevent moisture from entering the outlet box and causing a
    short, use clear silicone sealant to outline the outside of the
    back plate where it meets the wall, leaving a space at the bottom
    to allow moisture a means to escape.
  15. Return power to the outlet box and test the fixture.

INSTALLATION INSTRUCTIONS
Model # 72133-66 READ AND SAVE THESE INSTRUCTIONS
W ARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.

AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.

PREPARING FOR INSTALLATION (Fig. 1)

1. Shut off power at the fuse box or circuit breaker box and

remove the old fixture including the mounting hardware.

2. Carefully unpack your new fixture and lay out all the

parts in a clear area. Take care not to misplace any

small parts necessary for installation.

3. Remove screws (F) and rubber washers (E) and

separate mounting plate (C) from back plate (G). 4. Position mounting plate (C) on wall and mark location of

four drywall anchors (O). Pre-drill holes for drywall anchors

(O). Insert drywall anchors (O) into wall.

5. Attach mounting plate (C) to outlet box (A) (Not

included) with outlet box screws (D). Note: The side of

mounting plate marked “GND” must face out.

6. Place woodscrews (N) through holes into drywall anchor

(O) to secure mounting plate (C) as shown in Fig.1.

7. The support cable (P) is provided to support weight of

fixture while wiring. Align fixture to mounting plate (C)

and attach hook (Q) on the end of support cable (P) into

a slot located on mounting plate (C). Carefully allow the

support cable (P) to support the weight of the fixture

while wiring (Fig.1)

8. Remove screws (K), separate cover (M) from fixture

body (H), and install glass panels (L) into holder of

fixture body (H) and secure with tabs (I) on top and

bottom.

9. Install candelabra base bulbs (J) up to 60 watts or CFL

or LED equivalent (not included) in accordance with the

fixture specification. –DO NOT EXCEED THE

MAXIMUM WATTAGE RATING! (NE PAS DEPASSER

LA PUISSANCE NOMINALE MAXIMALE!)

Fig. 1

Part# A-020-235294 Mounting Plate (1) Mounting Screws (2) Ground Screw (1)

P

G H

Glass# G72133 for 72133-66 Candle Cover# CCV21070P-66 for 72133-66

Fig.2
FIXTURE WIRES BLACK

FIXTURE WIRES WHITE

FIXTURE WIRES GREEN OR BARE
COPPER (GROUND)

CONNECTING THE WIRES (Fig. 2) 10. Connect the electrical wires as shown in Fig.2. Making
sure that all wire connectors (B) are secured. If your
outlet box (A) has a ground wire (green or bare copper), connect fixture’s ground wire to it. Otherwise, connect fixture’s ground wire directly to mounting plate (C) using green screw provided. 11. Tuck wire connectors neatly into outlet box (A).

HOUSE WIRES BLACK (HOT)
Fig 3

HOUSE
WIRES WHITE
(NEUTRAL)

HOUSE WIRES GREEN OR
BARE COPPER(GROUND)

FINISHING THE INSTALLATION (Fig.1) 12. Align back plate (G) onto mounting plate (C) and secure
with rubber washers (E) and screws (F). 13. Place cover (M) onto fixture body (H) and secure with
screws (K). 14. To prevent moisture from entering the outlet box (A)
and causing a short, use clear silicone sealant to outline the outside of back plate (G) where it meets wall leaving a space at bottom to allow moisture a means to escape. (Fig .3)

Backplate

Caulking

Your installation is now complete. Return power to the outlet box and test the fixture.
IMPORTANT: FIXTURE SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN TO ENSURE PROPER WIRING AND INSTALLATION.