The product being installed is a Model #72133-66 fixture. The
installation instructions include preparing for installation,
connecting the wires, and finishing the installation.
The installation process involves shutting off power at the fuse
or circuit breaker, removing the old fixture with mounting
hardware, unpacking the new fixture and laying out all parts,
positioning the mounting plate on the wall, attaching the mounting
plate to the outlet box with outlet box screws, securing the
mounting plate with woodscrews, installing glass panels into the
holder of fixture body, and installing candelabra base bulbs up to
60 watts or CFL or LED equivalent in accordance with the fixture
specification.
The fixture has three wires: black (hot), white (neutral), and
green or bare copper (ground). The electrical wires are connected
with wire connectors, ensuring they are secured. If the outlet box
has a ground wire, connect the fixture’s ground wire to it.
Otherwise, connect the fixture’s ground wire directly to the
mounting plate using a green screw provided.
To prevent moisture from entering the outlet box and causing a
short, clear silicone sealant should be used to outline the outside
of the back plate where it meets the wall, leaving a space at the
bottom to allow moisture a means to escape.
It is important to note that the fixture should be installed by
a qualified electrician to ensure proper wiring and
installation.
Product Usage Instructions
- Shut off power at the fuse box or circuit breaker box and
remove the old fixture including mounting hardware. - Carefully unpack your new fixture and lay out all parts in a
clear area. Take care not to misplace any small parts necessary for
installation. - Remove screws and rubber washers and separate mounting plate
from backplate. - Position mounting plate on the wall and mark the location of
four drywall anchors. Pre-drill holes for drywall anchors and
insert them into the wall. - Attach mounting plate to outlet box with outlet box screws.
Note that the side of the mounting plate marked GND must face
out. - Place woodscrews through holes into drywall anchor to secure
mounting plate as shown in Fig.1. - The support cable is provided to support the weight of the
fixture while wiring. Align the fixture to the mounting plate and
attach the hook on the end of the support cable into a slot located
on the mounting plate. Carefully allow the support cable to support
the weight of the fixture while wiring. - Remove screws, separate cover from fixture body, and install
glass panels into the holder of the fixture body and secure them
with tabs on top and bottom. - Install candelabra base bulbs up to 60 watts or CFL or LED
equivalent (not included) in accordance with the fixture
specification. DO NOT EXCEED THE MAXIMUM WATTAGE RATING. - Connect the electrical wires as shown in Fig.2, ensuring that
all wire connectors are secured. If the outlet box has a ground
wire, connect fixture’s ground wire to it. Otherwise, connect
fixture’s ground wire directly to mounting plate using green screw
provided. - Tuck wire connectors neatly into outlet box.
- Align backplate onto mounting plate and secure with rubber
washers and screws. - Place cover onto fixture body and secure with screws.
- To prevent moisture from entering the outlet box and causing a
short, use clear silicone sealant to outline the outside of the
back plate where it meets the wall, leaving a space at the bottom
to allow moisture a means to escape. - Return power to the outlet box and test the fixture.
INSTALLATION INSTRUCTIONS
Model # 72133-66 READ AND SAVE THESE INSTRUCTIONS
W ARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
PREPARING FOR INSTALLATION (Fig. 1)
1. Shut off power at the fuse box or circuit breaker box and
remove the old fixture including the mounting hardware.
2. Carefully unpack your new fixture and lay out all the
parts in a clear area. Take care not to misplace any
small parts necessary for installation.
3. Remove screws (F) and rubber washers (E) and
–
separate mounting plate (C) from back plate (G). 4. Position mounting plate (C) on wall and mark location of
four drywall anchors (O). Pre-drill holes for drywall anchors
(O). Insert drywall anchors (O) into wall.
5. Attach mounting plate (C) to outlet box (A) (Not
included) with outlet box screws (D). Note: The side of
mounting plate marked “GND” must face out.
6. Place woodscrews (N) through holes into drywall anchor
(O) to secure mounting plate (C) as shown in Fig.1.
7. The support cable (P) is provided to support weight of
fixture while wiring. Align fixture to mounting plate (C)
and attach hook (Q) on the end of support cable (P) into
a slot located on mounting plate (C). Carefully allow the
support cable (P) to support the weight of the fixture
while wiring (Fig.1)
8. Remove screws (K), separate cover (M) from fixture
body (H), and install glass panels (L) into holder of
fixture body (H) and secure with tabs (I) on top and
bottom.
9. Install candelabra base bulbs (J) up to 60 watts or CFL
or LED equivalent (not included) in accordance with the
fixture specification. –DO NOT EXCEED THE
MAXIMUM WATTAGE RATING! (NE PAS DEPASSER
LA PUISSANCE NOMINALE MAXIMALE!)
Fig. 1
Part# A-020-235294 Mounting Plate (1) Mounting Screws (2) Ground Screw (1)
P
G H
Glass# G72133 for 72133-66 Candle Cover# CCV21070P-66 for 72133-66
Fig.2
FIXTURE WIRES BLACK
FIXTURE WIRES WHITE
FIXTURE WIRES GREEN OR BARE
COPPER (GROUND)
CONNECTING THE WIRES (Fig. 2) 10. Connect the electrical wires as shown in Fig.2. Making
sure that all wire connectors (B) are secured. If your
outlet box (A) has a ground wire (green or bare copper), connect fixture’s ground wire to it. Otherwise, connect fixture’s ground wire directly to mounting plate (C) using green screw provided. 11. Tuck wire connectors neatly into outlet box (A).
HOUSE WIRES BLACK (HOT)
Fig 3
HOUSE
WIRES WHITE
(NEUTRAL)
HOUSE WIRES GREEN OR
BARE COPPER(GROUND)
FINISHING THE INSTALLATION (Fig.1) 12. Align back plate (G) onto mounting plate (C) and secure
with rubber washers (E) and screws (F). 13. Place cover (M) onto fixture body (H) and secure with
screws (K). 14. To prevent moisture from entering the outlet box (A)
and causing a short, use clear silicone sealant to outline the outside of back plate (G) where it meets wall leaving a space at bottom to allow moisture a means to escape. (Fig .3)
Backplate
Caulking
Your installation is now complete. Return power to the outlet box and test the fixture.
IMPORTANT: FIXTURE SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN TO ENSURE PROPER WIRING AND INSTALLATION.