Rasonic Rwh-ct5 Unvented Instant Storage Hybrid Water Heater Instruction Manual

RWH-CT5 Unvented Instant Storage Hybrid Water Heater

Product Information

The Unvented Instant Storage (Hybrid) Water Heater is designed
for household use only. It is a high-performance water heater that
provides instant hot water. The product models available are
RWH-CT5 and RWH-CT7.

Product Usage Instructions

  1. Read the instruction manual carefully before using the
    appliance.
  2. The installation, commissioning, and maintenance of the water
    heater should only be done by an authorized technician who will
    adhere to the applicable standards and installation
    regulations.
  3. Ensure that all spare parts provided by the manufacturer are
    duly installed. Non-compliance with these instructions may result
    in damages for which the manufacturer is not liable.
  4. Do not use unauthorized components or devices as they may void
    the warranty provided by the sole distributor.
  5. Ensure that the appliance is properly earthed for safety.
  6. The appliance should only be used when correctly installed by
    an authorized technician and in good working order.
  7. Before switching on the appliance, ensure that it is completely
    filled with water and air bubbles are released from inside the
    water tank.
  8. Do not modify the wiring and piping of the appliance provided
    by the manufacturer.
  9. Be cautious as the hot water outlet and fittings may become
    very hot. Keep away from children.
  10. Depending on local Electrical Laws and Regulations, either a
    miniature circuit breaker (MCB) or an earth-leakage circuit breaker
    (ELCB) should be provided and fixed by the client.
  11. It is normal for water to drip from the Temperature and
    Pressure Relief Valve (P&T Valve) while the water is being
    heated.
  12. Before opening the maintenance access panel, ensure that the
    appliance is disconnected from the main power supply.
  13. Do not switch on the appliance if there is a possibility that
    the water inside the heater is frozen.
  14. The water inlet of this appliance should not be connected to
    the water inlet of any other water heating systems.
  15. Do not allow children to play or touch the water heater. Always
    supervise children to prevent electrical shock or injuries.
  16. This appliance is not intended to be operated by children or
    disabled persons alone.

Installation and Operating Instructions

Unvented Instant Storage (Hybrid) Water Heater

For household use only

RWH-CT5

RWH-CT7

Please read this instruction carefully before using this appliance
· · Please read the operation instruction carefully before using and well keep it in a safe place for future reference. · · Some figures in this instruction may not match with the real object, just for reference only.

Content

1. Safety Guideline

………………………………………… 4-5

2. Product Introduction and Packing List ………………………………….. 6-7

3. Product Information

……………………………………………………8

4. Product Structure

…………………………………………………8

5. Installation Instructions

……………………………………………………9

6. Pre-Installation Notice

………………………………………………10-11

7. Installation Diagram

………………………………………………….. 12

8. Wiring Diagram

………………………………………………….. 12

9. Technical Specification

………………………………………………13-14

10. Operating Instructions

………………………………………………….15

11. Troubleshooting

………………………………………………..16

12. Cleaning and Maintenance

………………………………………………..17

13. Warranty Terms

…………………………………………………18

SAFETY GUIDELINE
Installation, commissioning and maintenance of this appliance may only be undertaken by an authorized technician who will then be responsible for adhering to the applicable standards and/or installation regulations.
All spare parts provided by the manufacturer must be duly installed. We are not liable for any damages caused by non-compliance with these instructions.
Sole Distributor will not provide warranty service on any product installed with unauthorized components or devices.
** WARNING ** : The appliance must be EARTHED.
The appliance may only be used when correctly installed by authorized technician and in good working order.
The appliance must be completely filled with water and air bubbles released inside the water tank before being switched on.
The spare parts provided by the manufacturer must be installed and its wiring and piping must not be modified in any way. The hot water outlet and fittings may be very hot! Keep away from children.
Subject to local Electrical Laws and Regulations, one of the followings may be provided (Provision and fixation by client): i. miniature circuit breaker (MCB) ii. earth-leakage circuit breaker (ELCB)
It is normal if water drips from the Temperature and Pressure Relief Valve (P&T Valve) while the water is being heated.
The maintenance access panel of the appliance must never be opened before disconnecting the appliance from the main power supply.
Do not switch on if there is a possibility that the water in the heater is frozen. The water inlet of this appliance shall not be connected to water inlet of any other water heating
systems. Do not allow children to play or touch with the water heater, guardian need to supervise children,
to prevent the electrical shock or any injuries. This appliance is not intended to be operated by children or disabled persons alone.
They must be supervised by adults who are responsible for their safety. This appliance is not to be used for a potable water supply. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
authorized technician in order to avoid a hazard. Check water temperature before use, the shower head should always be pointed away from
human before cold water is turned on. After use, turn the mixer to cold arrow and shut off. Disconnect the power supply if the appliance is idle for a prolonged period.
The initial operation procedures must be carried out before reuse.
4

** ** : , ():
i. (MCB) ii. (ELCB) , , ,
5

PRODUCT INTRODUCTION AND PACKING LIST
Technical Principal
ISM Hot Water Injection System Rasonic’s Water Heater apply a 3rd Generation patented Hot Water Injection System, including Combustion Chamber with rapid burner (3kW rating) operated as: Combustion Injection Suction, to transform the phase of water into hot water and inject through passage to the vessel top instantly for storage and direct connected to the hot water pipe works such as central or hot bath system when in use.
Multiple safety protection devices
PID temperature controller Rasonic’s Water Heater series, it applies the world latest PID concept temperature control to maintain the preset temperature between 2 degree celsius deviation and alert in high temperature and sensor missing. Most of the electronic components and operated software are integrated in the module and enclosed in the fire resistance enclosure, it provide precision and accuracy with easier to repair and maintenance.

Product

1

Installation and Operation Instructions

2

Warranty Card

Water Saving Shower Head Set

3

( Including- Shower Head, Flexible Tube and Bracket )

(clients should install the original parts as specify in installation manual)

4

Temperature & Pressure Relief Valve ( P&T Valve )

5

Mounting Bracket with Anchor Bolts

Water Flow Restriction Orifice fixed between supply

6

pipe to Heater inlet pipe x 6L/min (Blue)

(clients should install the original parts as specify in installation instruction)

Water Flow Restriction Orifice fixed between water

7

Mixer to Shower Head x 4L/min (Green)

(clients should install the original parts as specify in installation instruction)

Unit 1 1
1 set 1
1 set 1
1

6

ISM 3
PID PID2°C

1

2

3

()

4

5

M6

6 6/()
()

7

4/ ()

()

1 1 1 1 1 1 1

7

PRODUCT INFORMATION

Measurements

Model No.

Height

RWH-CT5

690mm

RWH-CT7

690mm

RWH-CT5 RWH-CT7

690 690

PRODUCT STRUCTURE

Width 380mm 380mm
380 380

Depth 168mm 195mm
168 195

8

INSTALLATION INSTRUCTIONS

The appliance may only be installed in a frost-free environment. Power switch with a light indicator is recommended. The appliance needs to be permanently connected to the water mains and should not
connected by a flexible rubber hose. The appliance can be connected to one or more water outlet, e.g. mixing valve,
washing machine, shower head, etc. Water mains supply pressure should not be less than 0.3MPa. P&T Valve must be installed to the appliance, following EN 1490, ANSI Z21.22 or
AS1357.1 standard; where temperature should not exceed 99 °C and working pressure at 1.0MPa (10 bar). Tighten and connect a drain pipe (not supplied by manufacturer) to the pressure and temperature relief valve Water might drip from the P&T Valve as the water is being heated. The drain pipe must never be blocked and left open to atmosphere The drain pipe is to be installed in a downward direction from the P&T valve to 150mm above the floor, where the drain pipe outlet is clearly visible To drain off the water in water tank: i. Switch off the power and water supply
ii. Unscrew and remove the bottom maintenance access panel iii. Unbolt the drain plug (labeled “DRAIN”)

,

,

0.3MPa

, EN 1490ANSI Z21.22 AS 1357.1,99°C 1.0MPa (10bar)

()

,

, 150

: 1.

2.

3. (“DRAIN”)

9

Pre – Installation Notice
Installation and inspection should be processed by a licensed technician using the supplied parts. Sole Distributor is not responsible for any defect or damage caused by
incorrect or unauthorized installation.
Positioning Water heater should position near water tap of use in order to minimize heat loss and defects. For wall-mount installation, appropriate anchor screws must be used, and wall should be strong enough to withstand the weight of water heater. Installation position should keep a minimal distant between the wall and water heater.
Connecting P&T Valve and Inlet/Outlet Pipes The Temperature & Pressure Relief Valve ( P&T Valve) has applied in water heater, when the temperature/ pressure in water heater is detected to be more than setting (99°C /1.0MPa (10bar)),water will be released through the P&T Valve to decrease pressure and temperature.
P&T Valve and Inlet/Outlet Pipes must be installed according to the following instructions:
1. Please refer to the P&T Valve installation label indicated on the water heater, P&T Valve must be installed on the accurate position according to the installation label.
2. When connecting the pipe of P&T Valve , the P&T Valve must be installed downward. The outlet of the discharge pipe connecting the P&T Valve must be positioned approximately 100~150mm away from the ground, so that it is easily observable when hot water is being drained to ensure user safety.
3. The diameter of piping should be 1/2″ BSP. Connect the inlet pipe (blue) with water supply. Then connect the outlet pipes (red) with supply pipe leading to points of use.
4. Turn on the hot water tap. Turn on water supply switch until the inner tank has been filled up with water. The inner tank has been filled up when water flows from the water tap.
Power Switch
The external switch is used to completely disconnect water heater from power supply. It should disconnect all poles, and a contactor separation of at least 3mm must be present.
Initial Operation
! Important: Rasonic’s water heater hybrid series is designed for operation on 220VAC, and must be installed by authorizes technician with earthed outlet.
Fill the inner tank with water before conducting the following procedures: · Ensure that the appliance is disconnected and that the fuse is deactivated. · Turn on the hot water tap of the installed mixer to fill the appliance until
bubble-free water emerges from the outlet. · Check the system for leaks and remedy these if necessary. · Switch on the appliance. · The inner tank water temperature will automatic setting and remain in
attendance while the water
10

P&T Valve/ 99 /1.0MPa (10bar)P&T Valve
P&T Valve 1. P&T Valve P&T Valve 2. P&T Valve P&T Valve
100 ~ 150 3. ½”()()
4. ()

3
! :
220 · · · · ·
P&T Valve
11

690mm 180mm
195mm

INSTALLATION DIAGRAM
70mm 34mm P&T Valve

Hanger 60mm

Hot water outlet

G1/2″

G1/2″

380mm

Water inlet

190mm

100mm
Cable entrance

WIRING DIAGRAM

12

TECHNICAL SPECIFICATION

Model No. Inner Container
Capacity

RWH-CT5

RWH-CT7

SUS304 Stainless Steel

20L

24L

Maximum Pressure
Insulation
Rated Voltage
Rated Loading
Rated Current
Pipe Connection Working Temperature
(Inner-Tank) Water Protection Class
Non-return device Net Weight (Approx.)
Weight – with water (Approx.)

Working Pressure 1.0 MPa (10Bar) Static Pressure 0.6MPa (6Bar)
PU-fire retardant CFC -free
220V ~ 50Hz

3kW 13.4 Ampere G 1/2″ Male BSP (British Standard Pipe Thread ) 75 -80dg.C

13 kg

IPX4 Built-in

15 kg

33 kg

39 kg

13

()
() () () () ()

RWH-CT5

SUS304

RWH-CT7

20

24

1.0 MPa (10Bar) 0.6MPa (6Bar)

CFC

220 ~ 50 3

13.4 A() 1/2″ ()
75~80 IPX4

13 33

15 39

14

OPERATING INSTRUCTIONS
Draining To drain off water from the inner tank: 1st – Turn off both power and water supply. Let hot water inside the inner tank cool down if need. 2nd – Unscrew the drain plug to release water. Source of Water Supply Never connect Rasonic’ s water heater to other source of water supply, other than the potable water supply as the result will have no warranty to the Company. Water Shortage During water shortage, do not drain water from inner tank. The heating element would be damaged if it is not submerged under water. When water supply resumes, turn on hot water tap and let water flows through the shower head before switching on the power.

:
15

TROUBLESHOOTING

Problem No water outflow
Water outflow too weak No hot water outflow
Water not hot enough
Steam emerges
Short-circuit

Remedy
Check and ensure all main water taps, service valves are opened; check fittings and hose connections.
Check if water pressure is normal and ensure no blockage in the valve.
Check fuse and electrical connection, call customer service department to check thermal cutout, main controller or heating element if fuse and electrical connection is normal.
Check if the water temperature setting is appropriate; or if a large amount of hot water has been consumed, allow time for water to heat up.
Call customer service department to check thermal cutout, main controller or heating element.
Switch off the power supply and water tap, call customer service department to check thermal cutout, main controller or heating element.

; ,

,

16

CLEANING AND MAINTENANCE
· Heater surfaces and fittings may only be wiped with a damp cloth. Never use abrasive cleaning agents or solvents.
· The electrical and plumbing components should be inspected by an authorized technician every two years to ensure proper functioning and operational safety at all times.
· The P&T Valve is to be operated regularly to remove lime deposits and to ensure there is no blockage;
· The P&T Valve must be vented slightly at regular intervals (once per month) to ensure proper functioning – Pull the lever until the valve opens and water drains from the outlet. Re-close the valve. – If water continues to drip from the P&T Valve, call authorized technician to examine the P&T Valve.
· Cleaning the inner tank once a year is recommended: – close all valves and disconnect the power supply, – dismantle the drainage plug and drain off water to the drainage, slightly open the stop valve to clean the inner tank, tighten the plug after cleansing and repeat the `Initial Operation’ procedures.

· · · ·
– – · – –
17

WARRANTY TERMS
12 10*

These warranty terms shall be applicable
provided that the appliance is purchased, installed and used in accordance to domestic
laws and regulations; From the date of purchase, a 12-month limited liability warranty is provided; and 10-year limited liability warranty for the inner tank*

·

·

QR code Scan QR code for Online
Warranty Registration

Users must comply with the following instructions within the warranty period:
· Register the warranty information within 10 days of purchase
· Present warranty card and original stamped purchase invoice from distribution agent

* *This warranty is only for maintenance of the inner tank, all inspection,
delivery and installation/dismantling fee shall be charged separately

– – – – – 0.6MPa

The warranty is invalid if:
-The appliance is incorrectly installed -The appliance is modified -The appliance is not installed and operated in
accordance to this manual -The appliance is used for commercial or industrial
purposes -The incoming water pressure exceeds 0.6MPa
without installing a valid pressure control device

: : 469-471 : (852) 2310-1210 : (852) 2300-1255 : www.energytrading.com.hk : (852) 2667-6662 WhatsApp: (852) 9867-6452

Sole Distributor:
ENERGY TRADING COMPANY LIMITED Address: 13/F.,SUNBEAM COMMERCIAL BUILDING, 469-471 NATHAN ROAD, Kowloon, Hong Kong TEL: (852) 2310-1210 FAX: (852) 2300-1255 Website: www.energytrading.com.hk
Service Hotline: (852) 2667-6662 WhatsApp: (852) 9867-6452

Special Avowal
1) If information above has been checked; our company reserves the hermeneutic power to any print errors or misunderstanding on the content.
2) In case there is any inconsistency or conflict between the English versions and Chines versions of the terms, the Chinese versions shall prevail.
1) 2)

18

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals