CP-3000 Flexible 3000 Amp Current Probe
Product Information:
Product Name: Flexible 3000 Amp Current
Probe
Model: CP-3000
Manufacturer: LUTRON ELECTRONIC
Certifications: ISO-9001, CE, IEC1010
Features:
- Range: 30 A/ 300 A/ 3000 A
- Output Sensitivity: 100 mV/ A, 10 mV/ A, 1 mV/ A
- Output Voltage: 3 ACV (30 A, 300 A, 3000 A)
- Flexible Probe Length: 600 mm (23.6 inch)
- Optional current probe for DW-6093, DW-6095
Specifications:
- Measurement Ranges: 30 A/ 300 A/ 3000 A
- Frequency Range: 45 to 400 Hz
- Accuracy: Linear to 100% of range value
- Power Supply: From the meter (DW-6093, DW-6095), battery not
necessary - Enclosure Material: UL 94-V0 rated
Product Usage Instructions:
- Ensure the power supply is connected to the meter (DW-6093,
DW-6095). The probe does not require a separate battery. - Connect the signal output plug (+, red) and signal output plug
(-, black) to the appropriate ports on the device or instrument you
are using. - Set the desired measurement range using the 3000A/ 300A/ 30A
range switch on the main circuit unit. - Position the flexible probe around the conductor you wish to
measure. It is recommended to keep a distance of at least 25 mm (1
inch) between the measured conductor and the probe locker. - Ensure there is a distance of at least 200 mm (8 inches)
between different flexible current probes to avoid external field
influence. - Make sure the measured conductor’s position is on the center of
the flexible current probe for accurate measurements. - Verify that the power LED lamp on the main circuit unit is
illuminated, indicating that the device is powered on. - Read the measurement values from the device or instrument you
are using, taking into account the output sensitivity and voltage
specifications mentioned in the product information.
Battery pow er, AC to DC adapter pow er
Flexible 3000 Amp current probe
Model : CP-3000
ISO-9001, CE, IEC1010
LUTRON ELECTRONIC
30 A/ 300 A/ 3000 A, 100 mV/ A, 10 mV/ A, 1 mV/ A For 3 phase pow er analyzer DW-6093, DW-6095
3000A FLEXIBLE CURRENT PROBE
Model : CP-3000
ISO-9001, CE, IEC1010
LUTRON ELECTRONIC
Flexible 3000 Amp
CURRENT PROBE
Model : CP-3000
FEATURES
* Range : 30 A/ 300 A/ 3000 A.
Oper at ing
0 to 50 ( 32 to 122 ).
* Output sensitivity : 100 mV/ A, 10 mV/ A, 1 mV/ A.
Tem per at ur e
* Output voltage : 3 ACV ( 30 A, 300 A, 3000 A ).
Oper at ing
Less than 80% RH.
* Flexible probe length : 600 mm ( 23.6 inch ).
Hum idit y
* Optional current probe for DW-6093, DW-6095.
Dimension
Main circuit unit :
* When change the new probe, the calibration
105 x 56.5 x 33 mm.
procedures are not necessary to be executed.
( 4.1 x 2.2 x 1.3 inch ).
* Signal output use the banana plugs, durable and safety.
Flexible probe :
* Power supply is from the meter (DW-6093, DW-6095 ),
600 mm x 14.5 mm DI A.
battery is not necessary.
23.6 inch x 0.57 inch DI A.
Cable length :
SPECI FI CATI ONS
3.4 meters ( 11.2 feet ).
Measurement 30 A/ 300 A/ 3000 A, 3 ranges,
DC plug size :
ranges
switch selectable
5.5 mm x 2.5 mm DI A.
1st range value : 30 A
Weight
480 g ( 1.06 LB ).
2nd range value : 300 A
Accessory
Operating manual …………………1 PC.
3rd range value : 3000 A
I ncluded
Out put
100 mV/ A, 10 mV/ A, 1 mV/ A,
sensit ivit y
AC coupled.
FRONT PANEL DESCRI PTI ONS
Accuracy
± 1% of range value
* Accuracy is specified that the
measured conductor’s position is
on the center of ” Flexible current
probe “.
3-1 Flexible current probe
* 50/ 60 Hz..
* 23 ± 5
3-2 Probe locker
Frequency
45 to 400 Hz.
range
* Accuracy tested under 50/ 60 Hz.
3-3 Main circuit unit
Linear it y
± 0.2 % of reading value from 10 %
to 100% of range value.
3-4 3000A/ 300A/ 30A
Phase error < ± 1.5°
range switch
* 50/ 60 Hz..
Conduct or
± 2 % of range value.
3-5 Cable
posit ion
* Recommend the measured conductor
sensit ivit y
position should > 25 mm ( 1″ )
3-6 DCV power plug
away from the ” Probe locker “.
Ext er nal
increase ± 1.5 % of range value max..
3-7 Signal output plug
field
* Recommend the distance between
( + , red )
influence
different ” Flexibel current
probe ” should > 200 mm ( 8″ ).
3-8 Signal output plug
Minimum
100 K ohm for specified accuracy.
( -, black )
load
Enclosure
UL 94-V0 rated.
3-9 Power LED lamp
m at er ial
Saf et y
I EC 1010, Categories I I I 600V.
Power Supply Power supply is from the meter
(DW-6093, DW-6095 ), battery is not
necessary.
* Power supply voltage from DW-6093,
DW-6095 is DC 8V± 1V..
* Appearance and specifications listed in this brochure are subject to change without notice.