Lutron Cp-3000 Flexible 3000 Amp Current Probe Instructions

CP-3000 Flexible 3000 Amp Current Probe

Product Information:

Product Name: Flexible 3000 Amp Current
Probe

Model: CP-3000

Manufacturer: LUTRON ELECTRONIC

Certifications: ISO-9001, CE, IEC1010

Features:

  • Range: 30 A/ 300 A/ 3000 A
  • Output Sensitivity: 100 mV/ A, 10 mV/ A, 1 mV/ A
  • Output Voltage: 3 ACV (30 A, 300 A, 3000 A)
  • Flexible Probe Length: 600 mm (23.6 inch)
  • Optional current probe for DW-6093, DW-6095

Specifications:

  • Measurement Ranges: 30 A/ 300 A/ 3000 A
  • Frequency Range: 45 to 400 Hz
  • Accuracy: Linear to 100% of range value
  • Power Supply: From the meter (DW-6093, DW-6095), battery not
    necessary
  • Enclosure Material: UL 94-V0 rated

Product Usage Instructions:

  1. Ensure the power supply is connected to the meter (DW-6093,
    DW-6095). The probe does not require a separate battery.
  2. Connect the signal output plug (+, red) and signal output plug
    (-, black) to the appropriate ports on the device or instrument you
    are using.
  3. Set the desired measurement range using the 3000A/ 300A/ 30A
    range switch on the main circuit unit.
  4. Position the flexible probe around the conductor you wish to
    measure. It is recommended to keep a distance of at least 25 mm (1
    inch) between the measured conductor and the probe locker.
  5. Ensure there is a distance of at least 200 mm (8 inches)
    between different flexible current probes to avoid external field
    influence.
  6. Make sure the measured conductor’s position is on the center of
    the flexible current probe for accurate measurements.
  7. Verify that the power LED lamp on the main circuit unit is
    illuminated, indicating that the device is powered on.
  8. Read the measurement values from the device or instrument you
    are using, taking into account the output sensitivity and voltage
    specifications mentioned in the product information.

Battery pow er, AC to DC adapter pow er

Flexible 3000 Amp current probe

Model : CP-3000

ISO-9001, CE, IEC1010

LUTRON ELECTRONIC

30 A/ 300 A/ 3000 A, 100 mV/ A, 10 mV/ A, 1 mV/ A For 3 phase pow er analyzer DW-6093, DW-6095

3000A FLEXIBLE CURRENT PROBE

Model : CP-3000

ISO-9001, CE, IEC1010

LUTRON ELECTRONIC

Flexible 3000 Amp

CURRENT PROBE

Model : CP-3000

FEATURES

* Range : 30 A/ 300 A/ 3000 A.

Oper at ing

0 to 50 ( 32 to 122 ).

* Output sensitivity : 100 mV/ A, 10 mV/ A, 1 mV/ A.

Tem per at ur e

* Output voltage : 3 ACV ( 30 A, 300 A, 3000 A ).

Oper at ing

Less than 80% RH.

* Flexible probe length : 600 mm ( 23.6 inch ).

Hum idit y

* Optional current probe for DW-6093, DW-6095.

Dimension

Main circuit unit :

* When change the new probe, the calibration

105 x 56.5 x 33 mm.

procedures are not necessary to be executed.

( 4.1 x 2.2 x 1.3 inch ).

* Signal output use the banana plugs, durable and safety.

Flexible probe :

* Power supply is from the meter (DW-6093, DW-6095 ),

600 mm x 14.5 mm DI A.

battery is not necessary.

23.6 inch x 0.57 inch DI A.

Cable length :

SPECI FI CATI ONS

3.4 meters ( 11.2 feet ).

Measurement 30 A/ 300 A/ 3000 A, 3 ranges,

DC plug size :

ranges

switch selectable

5.5 mm x 2.5 mm DI A.

1st range value : 30 A

Weight

480 g ( 1.06 LB ).

2nd range value : 300 A

Accessory

Operating manual …………………1 PC.

3rd range value : 3000 A

I ncluded

Out put

100 mV/ A, 10 mV/ A, 1 mV/ A,

sensit ivit y

AC coupled.

FRONT PANEL DESCRI PTI ONS

Accuracy

± 1% of range value

* Accuracy is specified that the

measured conductor’s position is

on the center of ” Flexible current

probe “.

3-1 Flexible current probe

* 50/ 60 Hz..

* 23 ± 5

3-2 Probe locker

Frequency

45 to 400 Hz.

range

* Accuracy tested under 50/ 60 Hz.

3-3 Main circuit unit

Linear it y

± 0.2 % of reading value from 10 %

to 100% of range value.

3-4 3000A/ 300A/ 30A

Phase error < ± 1.5°

range switch

* 50/ 60 Hz..

Conduct or

± 2 % of range value.

3-5 Cable

posit ion

* Recommend the measured conductor

sensit ivit y

position should > 25 mm ( 1″ )

3-6 DCV power plug

away from the ” Probe locker “.

Ext er nal

increase ± 1.5 % of range value max..

3-7 Signal output plug

field

* Recommend the distance between

( + , red )

influence

different ” Flexibel current

probe ” should > 200 mm ( 8″ ).

3-8 Signal output plug

Minimum

100 K ohm for specified accuracy.

( -, black )

load

Enclosure

UL 94-V0 rated.

3-9 Power LED lamp

m at er ial

Saf et y

I EC 1010, Categories I I I 600V.

Power Supply Power supply is from the meter

(DW-6093, DW-6095 ), battery is not

necessary.

* Power supply voltage from DW-6093,

DW-6095 is DC 8V± 1V..
* Appearance and specifications listed in this brochure are subject to change without notice.