Gossen Metrawatt 210 Rogowski Flexible Ac Current Probe Instruction Manual

210 Rogowski Flexible AC Current Probe

Product Information

MAVOWATT 210 Rogowski

The MAVOWATT 210 Rogowski is a flexible AC current probe based
on the Rogowski Principle. It is manufactured by Gossen Metrawatt
GmbH.

Applications

The MAVOWATT 210 Rogowski is designed for specific purposes.
Please read the following important information:

  • Intended Use / Use for Intended Purpose: The
    product should be used only for the purposes described in the
    operating instructions. Using it for any other purpose is not
    recommended.
  • Use for Other than Intended Purpose: Using the
    product for purposes other than the intended purpose may lead to
    property damage, personal injury, or consequential damage. It is
    important to follow the product documentation.
  • Liability and Guarantee: Gossen Metrawatt GmbH
    does not assume any liability for property damage, personal injury,
    or consequential damage resulting from improper or incorrect use of
    the product. Additionally, guarantee claims are void in such cases.
    Gossen Metrawatt GmbH is also not liable for data loss.
  • Opening the Instrument / Repairs: Unauthorized
    modifications to the product are strictly prohibited.

The Product

The MAVOWATT 210 Rogowski has the following specifications:

  • Scope of Application: This documentation
    applies to the MAVOWATT 210 Rogowski 500/40 product.
  • Product Overview: The product is a flexible AC
    current probe based on the Rogowski principle. It is suitable for
    MAVOWATT 210 and has a measuring head length of 40 cm.
  • Relevant Standards: The product complies with
    relevant standards.
  • Technical Data: Detailed technical data can be
    found in the product documentation.

Product Usage Instructions

Installation

To install the MAVOWATT 210 Rogowski, follow these steps:

  1. Unpack the product carefully.
  2. Make the necessary measurement connections according to the
    product documentation.

Operation

The MAVOWATT 210 Rogowski can be operated by following the
instructions provided in the product documentation.

Maintenance

Maintain the MAVOWATT 210 Rogowski according to the guidelines
mentioned in the product documentation.

Contact, Support and Service

If you require any assistance or have any questions regarding
the MAVOWATT 210 Rogowski, please contact the Gossen Metrawatt GmbH
support team or refer to the provided contact information in the
product documentation.

CE Declaration

The MAVOWATT 210 Rogowski complies with CE regulations. The CE
declaration can be found in the product documentation.

Returns and Environmentally Sound Disposal

To return or dispose of the MAVOWATT 210 Rogowski, follow the
instructions provided in the product documentation for
environmentally sound disposal.

Operating Instructions

MAVOWATT 210 ROGOWSKI
Flexible AC Current Probe based on the Rogowski Principle

3-447-115-03 1/4.22

MAVOWATT 210 Rogowski
Contents

Gossen Metrawatt GmbH

1 Safety Precautions ……………………………………………………. 1
2 Applications ……………………………………………………………… 2
2.1 Intended Use / Use for Intended Purpose…………………………………….. 2 2.2 Use for Other than Intended Purpose ………………………………………….. 2 2.3 Liability and Guarantee ……………………………………………………………… 2 2.4 Opening the Instrument / Repairs ……………………………………………….. 2
3 The Product ……………………………………………………………… 3
3.1 Scope of Application ………………………………………………………………… 3 3.2 Product Overview…………………………………………………………………….. 3 3.3 Relevant Standards ………………………………………………………………….. 4 3.4 Technical Data ………………………………………………………………………… 5
4 Installation………………………………………………………………… 6
4.1 Unpacking the Product …………………………………………………………….. 6 4.2 Making Measurement Connections …………………………………………….. 6
5 Operation …………………………………………………………………. 7
6 Maintenance …………………………………………………………….. 7
7 Contact, Support and Service…………………………………….. 8
8 CE Declaration ………………………………………………………….. 9
9 Returns and Environmentally Sound Disposal……………… 9

Gossen Metrawatt GmbH
1 Safety Precautions

MAVOWATT 210 Rogowski

General · Carefully and completely read and adhere to these operating instructions.
The document can be found at http://www.gossenmetrawatt.com. Retain this document for future reference. · Carefully and completely read and adhere to the product documentation of the combined products. Retain these documents for future reference. · Observe and comply with all safety regulations which are applicable for your work environment.
Handling · The probe may only be used as long as it is fully intact.
Inspect all cables and the probe before use. Pay particular attention to damage, broken insulation or kinked cables. · If the probe doesn’t function flawlessly, remove it from operation and secure it against inadvertent use. · If the probe is damaged during use, e.g. through falling, remove it from operation and secure it against inadvertent use. · If the equipment is used in a manner not specified in this reference guide, the protection provided by the equipment may be impaired. These safety precautions are repeated where appropriate throughout this manual.
Operating conditions · Only use the probe in conjunction with the measuring device MAVOWATT
210. · Only use the probe in compliance with the specified technical data and
under the specified conditions (ambient conditions, IP protection class, measuring category, etc.). · Do not use the probe after long periods of storage under unfavorable conditions (e.g. humidity, dust or extreme temperature).
Electricity · Installation, operation, and maintenance of this product must be performed
by qualified personnel only. · Qualified personnel who work on or near exposed energized electrical con-
ductors must follow applicable safety related work practices and procedures including appropriate personal protective equipment. · Wear proper personal protective equipment, including safety glasses and insulated gloves when making connections to power circuits. · Hands, shoes, and floor must be dry when making any connection to a power line.

1

MAVOWATT 210 Rogowski

Gossen Metrawatt GmbH

· Never apply the probe around bare conductors with hazardous voltages without having the appropriate permission to perform such work and without wearing protective clothing and gloves as required.
· Connections must be made to the measuring device first, then to the circuit to be monitored.
· The probe may only be used within the limits of the specifications listed in this manual. Loads exceeding the specified values may destroy the probe and the electrical equipment connected to it.

2 Applications
Please read this important information!
2.1 Intended Use / Use for Intended Purpose
The MAVOWATT 210 Rogowski current probes are based upon the Rogowski principle. They can be used exclusively to measure AC current by being connected to MAVOWATT 210 Three-phase Power and Energy Logger. The flexible probes allow current measurements on conductors that are hard to reach. Installation, operation, and maintenance of this product must be performed by qualified personnel only. Safety of the operator, as well as that of the product, is only assured when it’s used for its intended purpose.
2.2 Use for Other than Intended Purpose
Using the product for any purposes other than those described in the condensed operating instructions or these product operating instructions is contrary to use for intended purpose.
2.3 Liability and Guarantee
Gossen Metrawatt GmbH assumes no liability for property damage, personal injury or consequential damage resulting from improper or incorrect use of the product, in particular due to failure to observe the product documentation. Furthermore, all guarantee claims are rendered null and void in such cases. Nor does Gossen Metrawatt GmbH assume any liability for data loss.
2.4 Opening the Instrument / Repairs
Unauthorized modifications to the product are prohibited.

2

Gossen Metrawatt GmbH
3 The Product

MAVOWATT 210 Rogowski

3.1 Scope of Application

This documentation applies to the following articles:

Product

Product no. Description

MAVOWATT 210 Rogowski 500/40

Z840A

Flexible AC current probe based on the Rogowski principle, suitable for MAVOWATT 210, 50 – 500 A, measuring head length 40 cm.

MAVOWATT 210 Rogowski 1500/40

Z840B

Flexible AC current probe based on the Rogowski principle, suitable for MAVOWATT 210, 150 – 1500 A, measuring head length 40 cm.

MAVOWATT 210 Rogowski 3000/40

Z840C

Flexible AC current probe based on the Rogowski principle, suitable for MAVOWATT 210, 300 – 3000 A, measuring head length 40 cm.

3.2 Product Overview
Flexible current probe

Probe output cable

Probe coupling Figure 1: Flexible AC current probes based on the Rogowski principle
3

MAVOWATT 210 Rogowski

Gossen Metrawatt GmbH

3.2.1 Symbols on the product and the included accessories:

Warning concerning a point of danger

!

(attention, observe documentation!)

Double insulation (protection category II)

Do not apply around or remove from hazardous live conductors without additional protective means.

European conformity marking
The device may not be disposed of with household trash “Returns and Environmentally Sound Disposal” 9.

3.3 Relevant Standards

The product has been manufactured and tested in accordance with the following safety regulations:

DIN EN 61326

Electrical Equipment for Measurement, Control and Laboratory Use – EMC Requirements

DIN EN 61010-1

Safety Requirements of Electrical Equipment for Measurement, Control, and Laboratory Use – Part 1: General Requirements

DIN EN 61010-1-031 Safety Requirements of Electrical Equipment for Measurement, Control, and Laboratory Use – Part 031: Safety Requirements for Hand-held Probe Assemblies for Electrical Measurement and Test

DIN EN 61010-2-032 Safety Requirements of Electrical Equipment for Measurement, Control, and Laboratory Use – Part 2-032: Particular Requirements for Hand-held and Hand-manipulated Current Sensors for Electrical Test and Measurement

4

Gossen Metrawatt GmbH

MAVOWATT 210 Rogowski

3.4 Technical Data

Rated Current

Measurement range

MAVOWATT 210 50 A – 500 A Rogowski 500/40
MAVOWATT 210 150 A – 1500 A Rogowski 1500/40
MAVOWATT 210 300 A – 3000 A Rogowski 3000/40

Accuracy

0.5% per IEEE C57.13 class 0.6

Positioning error

±0.1%

Operating Ambient temperature Conditions Relative humidity

-20 … +70 °C
5% to 95%, no condensation allowed

Phase orientation

Arrow points towards load

Electrical Frequency range

45 Hz – 65 Hz

Frequency response

10 Hz – 20 kHz

Safety

Working voltage Dielectric strength

1000 V CAT III, 600 V CAT IV
7400 Vac at 50/60 Hz for 1 minute

Protection

IP61 per DIN EN 60529 / IEC 60529

Coil length Mechanical Coil diameter Design
Window size

40 cm 15.5 mm 10.6 cm

Wire length

2m

Protection type

IP61

5

MAVOWATT 210 Rogowski
4 Installation

Gossen Metrawatt GmbH

4.1 Unpacking the Product
1. Carefully remove product and accessories from the packaging. 2. Check delivery for completeness and possible damage. 3. In case of detected damages, hidden defects and short deliveries, docu-
ment type and scope and contact the manufacturer or supplier immediately. 4. Keep packing material for further transport.

4.2 Making Measurement Connections
To perform measurements, the Rogowski current probes are first connected to MAVOWATT 210. Subsequently, the Rogowski current probes are connected to the object to be measured.

! Attention!
To avoid the risk of electric shock or burns, always connect the earth
ground before making any other connections.

! Attention!
Do not exceed the marked maximum ratings.
4.2.1 Connecting MAVOWATT 210 Rogowski Current Probes to MAVOWATT 210 MAVOWATT 210 is powered off. 1. Plug the output cable of the current probe to the current input of
MAVOWATT 210.
4.2.2 Connecting MAVOWATT 210 Rogowski Current Probes to the Circuit to be Measured
! Attention!
DO NOT attempt to measure current in any circuit in which the circuit to ground voltage exceeds the insulation rating of the current probe.

! Attention!
Make sure the current probes are tightly closed. Keep mating surfaces
clean and free from foreign matter.

6

Gossen Metrawatt GmbH

MAVOWATT 210 Rogowski

Note!
Do not locate the probe coupling close to other conductors carrying high current.

Note!
Be sure to connect the current probes with the arrow pointing towards the load or an erroneous power reading will result.
MAVOWATT 210 is powered off.
1. Open the probe coupling and slip the measuring head over the conductor carrying the current to be measured.
2. Close the probe coupling such that it visibly and audibly snaps into place. The arrow marking on the current probe points in the direction of current
flow and towards the load. The conductor is centered within the measuring head. The measuring head forms a perfect circle.

Figure 2: Placing the current probe
5 Operation
For the different measurement configurations, refer to the Operating Instructions of MAVOWATT 210.
6 Maintenance
Cleaning Keep the probe free of surface contamination. If necessary, clean the probe with isopropyl alcohol.
7

MAVOWATT 210 Rogowski
7 Contact, Support and Service

Gossen Metrawatt GmbH

You can reach Gossen Metrawatt GmbH directly and uncomplicated, we have one number for everything! Whether it’s a support question, or individual desire, we answer every request at:

+49-911-8602-0

Monday­Thursday: 8:00 a.m. ­ 4:00 p.m.

Friday:

8:00 a.m. ­ 2:00 p.m.

You can also e-mail to:

[email protected]

Do you prefer support via e-mail?

Measuring and test instruments:

[email protected]

Industrial equipment: [email protected]

For repairs, replacement parts, and calibrations1 please contact GMC-I Service GmbH:

+49-911-817718-0 [email protected] www.gmci-service.com

Beuthener Str. 41 90471 Nürnberg Germany

1. DAkkS calibration laboratory per DIN EN ISO/IEC 17025. Accredited at the Deutsche Akkreditierungsstelle GmbH under registration no. D-K15080-01-01.
8

Gossen Metrawatt GmbH
8 CE Declaration

MAVOWATT 210 Rogowski

The product fulfills all requirements of applicable EU directives and national regulations. We confirm this with the CE mark. The CE Declaration of Conformity is available upon request.

9 Returns and Environmentally Sound Disposal
This product is subject to directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE) and its German national equivalent implemented as the Waste Electrical and Electronic Equipment Act (ElektroG) on the marketing, return and environmentally sound disposal of electrical and electronic equipment. The product is a category 9 product (monitoring and control instrument) in accordance with ElektroG (German Waste Electrical and Electronic Equipment Act).
The symbol at the left indicates that this device and its electronic accessories must be disposed of in accordance with applicable legal regulations, and not together with household waste. In order to dispose of the device, bring it to a designated collection point or contact our product support department (8).
Separate disposal and recycling conserves resources and protects our health and the environment.
Current and further information is available on our website at http://www.gossenmetrawatt.com under the search terms “WEEE” and “environmental protection”.

9

MAVOWATT 210 Rogowski

Gossen Metrawatt GmbH

© Gossen Metrawatt GmbH Prepared in Germany · Subject to change, errors excepted · PDF version available on the Internet
All trademarks, registered trademarks, logos, product names, and company names are the property of their respective owners.

Gossen Metrawatt GmbH Südwestpark 15 90449 Nürnberg · Germany

Phone +49 911 8602-0 Fax +49 911 8602-669 E-mail [email protected] www.gossenmetrawatt.com

References

Documents / Resouces

Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.


Related Manuals