SK 5364 Limoges Grande Pendant
Product Information
Product Name: Limoges Grande Pendant
Item Number: SK 5364
This product is a light fixture that needs to be installed in
accordance with applicable local installation codes. It should be
installed by someone familiar with its construction and operation,
as well as the associated hazards. Before installation, carefully
inspect the item and its contents for any damage or defects. If any
issues are found, do not proceed with the installation. Retain all
packaging material until installation is complete and approved.
Tools Required (Not Included):
- Phillips Screwdriver
- Slotted Screwdriver
- Slip Joint Pliers
- Needle-nose Pliers
- Wire Cutters
- Wire Strippers
- Chain Pliers
- Measuring Tape
Product Usage Instructions
- Remove all parts from the box and place them on a clean, soft
surface. - Determine the desired overall length of the fixture and the
amount of chain (G) needed. - Wrap the fixture ground wire (bare copper) around the green
grounding screw (see diagram 2) and tighten it. Then, continue the
fixture ground wire and connect it to the supply ground wire
(usually green or bare copper) using a wire nut (A). Make sure the
fixture is properly grounded. - Connect the fixture neutral wire (ribbed) to the supply neutral
wire (usually white) using a wire nut (A). - Connect the fixture hot wire (smooth with markings) to the
supply hot wire (usually black) using a wire nut (A). Be cautious
not to reverse the hot and neutral connections. - Ensure that all wire connections are tight, and carefully tuck
them into the junction box. - Install the canopy (E) onto the collar loop (D) by securing it
with the collar ring (F). - Install a light bulb into the socket. Please note that the bulb
is not included.
Care Instructions:
Clean the fixture only with a soft dry cloth or feather duster.
Do not use abrasive or chemical agents.
Note: These instructions are a summary of the product user
manual. For complete and detailed instructions, please refer to the
original manual provided with the product.
ASSEMBLY INSTRUCTIONS
A
B C D E
Diagram 2
F
G
Bulb not included
Diagram 1
Limoges Grande Pendant
Item # SK 5364
NOTICE:
This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.
TOOLS REQUIRED (NOT INCLUDED):
Phillips Screwdriver
Slotted Screwdriver
Slip Joint Pliers
Needle-nose pliers
Wire Cutters
Wire Strippers
Chain Pliers Measuring Tape
1. Carefully remove all parts from the box. Place on a clean, soft surface. 2. Determine desired overall length, and amount of chain (G) needed.
Shorten chain using needle-nose pliers (see diagram 1). (Keep extra chain) 3. Remove mounting plate (B) from collar loop (D). 4. Thread fixture wire and ground wire through chain (G), collar ring (F) and canopy (E). NOTE: When you reach the collar loop (D), ensure there is no tension on the wires. Cut excess wires, being sure to leave about 12″ to reach the junction box. 5. Separate two sides of molded wire, and strip insulation on each 5/8″. 6. Twist all fixture wires together. Slip through center hole of collar loop (D). NOTE: Untwist wires and separate to prepare for connection. 7. Attach mounting plate (B) to collar loop (D) and secure using pliers to tighten locknut. 8. Install fixture by securing mounting plate (B) to the junction box using mounting screws (C).
M
LI ST ED
US
ASSEMBLY INSTRUCTIONS
A
B C D E
Diagram 2
F
G
Bulb not included
Diagram 1
Limoges Grande Pendant Item # SK 5364
NOTICE: This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.
9. Wrap fixture ground wire (bare copper) around the green grounding screw (see diagram 2). Tighten. Continue fixture ground wire and connect to supply ground wire (usually green or bare copper) using wire nut (A). NOTE: It is imperative that the fixture is grounded.
10. Connect fixture neutral wire (ribbed) to the supply neutral wire (usually white) using wire nut (A).
11. Connect fixture hot wire (smooth with markings) to the supply hot wire (usually black) using wire nut (A). CAUTION: Do not reverse the hot and neutral connections.
12. Make sure all wire connections are tight, then carefully tuck into the junction box.
13. Install canopy (E) to collar loop (D) by securing with collar ring (F). 14. Install light bulb into the socket.
Care Instructions: Clean only with a soft dry cloth or feather duster. Do not use abrasive or chemical agents.