Wagner Al8010f Refrigeration Or Heating Digital Thermostat User Manual

Wagner Al8010f Refrigeration Or Heating Digital Thermostat User Manual

Wagner logo

Wagner AL8010F Refrigeration or Heating Digital ThermostatWagner AL8010F Refrigeration or Heating Digital Thermostat product

AL801 Of is a digital thermostat based on Set-point & Hysteresis to control the power supply status of connected loads; with just one Relay too, viring a refrigerator or a heate£, the set-point temperature”e ranges from -50 to 120 °C.

Package

  • Controller:  1PCS
  • Fasteners: 2PCS
  • Sensor:  1PCS
  • Manual:  1PCS
  • Wate, proof cover:  1PCS

Specification

  • Input Power:  220V AC± 10% 50/60HZ; (12124/48/1 I0V Option)
  • Maximum current:  WA (Default) 1m.der 220V AC
  • Sensor:  NTC, 25°C 110 K.Q, the sensor cable 200cm
  • Protection Class:  .si!P6 5 t-0 the front panel
  • Storage:  -l 0°C – 60°C, RH <90%, without condensation
  • Measurable Range:  -5O°C – l 20°C
  • Controllable Range:  -5O°C – l 20°C
  • Resolution:  0- 99.9″‘C is 0. l °C, ofuer range 1 “C
  • Accuracy:  ± I 0c
  • Power Consumption:   W n3.

Interface & Operation

IFront Panel & Icon
Under normal status

  • When screen light, Hold  Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-0the II key for Js to tum off the controller;
  • When the screen is dark, press Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-0the II key to light on the semen.Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-1

Indicator/ character in the display

IndicatorMeaningOnHideWink
WorkWorking status of the loadload WorkingStopDelay
setSelling statusOn SetNon-settingN/A

 

Dimensions & InstallationWagner AL8010F Refrigeration or Heating Digital Thermostat fig-2

  1. Suggested amount dimension: 71 “’29*85mm (\V*H*D)
  2. Detach the slide fasteners, put the controller to the hole, wiring follow the diagram
  3. InstaU the fasteners and the wate1prnof cover.
  4. Please avoid installing in the below environments:
    • Relative humidity > 90%. have condensation
    • The places that temperature <-10°C or >60°C;
    • The places that have inflammable and explosives;
    • Strong vibration or struck
    • Exposed to the continuous water mist spraying;
    • Exposed to the dust;
    • Exposure to corrosive and pollution gas (e_g_, the gas, smoke, or salt fog)
    • Wireless electromagnetic interference or s•trong magnetic fields (near to transmitting antenna or switch: board room).

Wiring D1iagram

The input power voltage of the load and the controller could be different.Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-3

  1. OK NTC sensor, need not distinguish + or – when wiring it.
  2. The input voltage must be the within die range of Marked Voltage ±10%.
  3. Load! Power Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-2.0
    • The factor for Inductive Load like compressor, heating pump, usually be 5-8;
    • The factor for Resist:I’ve Load like Electric heating rod, Electric blanket usually is 1.5 – 2;
    • The factor for Incandescent lamps usually is 15.
Wiring DiagramWagner AL8010F Refrigeration or Heating Digital Thermostat fig-4

 

  1. HDK NTC sensor, Need not to distinguish + or • when wiring i.t
  2. The i.nputt voltage must be within the voltage value malice in diagram ± l 0% value.
  3. Load PowerWagner AL8010F Refrigeration or Heating Digital Thermostat fig-2.0
    • Th – factor for Induction.ve Load ll\:e c.ompli so:r, beating plump, usual y IDe:5~8 ·
    • The factor for Resistive Load like Electric heating rod Electric blanket usually is L:5~2
    • Th factor for Incandescent la1np, 111.Sua]ly is 1:5.
Configurations

Code ‘ and Function on Menu

CodeFunctionMinMaxDefualtStep
H[Heating ,or Cooling[H[
dRerut’i:lJ Diffe.renre (“C)115.51
tsLowest set Limit (“C)-50ATV-501
HSHighest Limit (“C)ATV1201201
[RTemperrature Calib ration (“C)-5+501
PtDe.la; Time Min)01011

What is ATV and how· to sec It?

ATV means Aim temperature value which is the ideal temperature you wish to reach. once exceed this va]ue (if difference value = 0) the status of load. will be changed, Details of setting as follow

step1:Assure power on P11 .s and releaseWagner AL8010F Refrigeration or Heating Digital Thermostat fig-5key once times you will find disp]ay blink a data which is changeable.
step2:· now press the Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-6o:r Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-7keys to get you aim value·

  • press and bold on the Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-6o:rWagner AL8010F Refrigeration or Heating Digital Thermostat fig-7is fast forward function;
  • the length of the step is 0.1. “C;
  • The editable range between lower Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-8 and higherWagner AL8010F Refrigeration or Heating Digital Thermostat fig-9 ]imit
  • The buzzer will scream once Roon. Temperature Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-10  or Room temperature Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-11press any key to stop screaming if you want to.

Step3:  Waiting for 1Os the device will save data automatically or pressWagner AL8010F Refrigeration or Heating Digital Thermostat fig-0to save it

Error & Alarm

When an alarm occurs if the readout flashes —and buzzer sounds

  • Press any key to stop buzz scream
  •  Check the room temperature and then change the compressor I heater working status manually i
  • necessary,
  • fix o:r replace the sensor; aft r bat screen wi]l back to manual slate
  • And older c.ode lease, r-efere1100 below content to fix the problem.Wagner AL8010F Refrigeration or Heating Digital Thermostat fig-19